Evaluation of bowel peristalsis by dynamic cine MRI: detection of relevant functional disturbances - initial experience

Purpose: To investigate the diagnostic performance of a cine magnetic resonance imaging (MRI) sequence in the visualization and detection of impaired bowel peristalsis. Materials and Methods: In all, 91 consecutive patients (mean age 45 years) were prospectively examined on a 1.5 T system and strati...

Full description

Saved in:
Bibliographic Details
Main Authors: Heye, Tobias (Author) , Stein, Daniel (Author) , Antolovič, Dalibor (Author) , Dueck, Margret (Author) , Kauczor, Hans-Ulrich (Author) , Hosch, Waldemar P. (Author)
Format: Article (Journal)
Language:English
Published: 2012
In: Journal of magnetic resonance imaging
Year: 2012, Volume: 35, Issue: 4, Pages: 859-867
ISSN:1522-2586
DOI:10.1002/jmri.22851
Online Access:Verlag, Volltext: http://dx.doi.org/10.1002/jmri.22851
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.22851
Get full text
Author Notes:Tobias Heye, MD, Daniel Stein, DSc, Dalibor Antolovic, MD, Margret Dueck, MD, Hans-Ulrich Kauczor, MD, and Waldemar Hosch, MD

MARC

LEADER 00000caa a2200000 c 4500
001 1576392139
003 DE-627
005 20220814163955.0
007 cr uuu---uuuuu
008 180615s2012 xx |||||o 00| ||eng c
024 7 |a 10.1002/jmri.22851  |2 doi 
035 |a (DE-627)1576392139 
035 |a (DE-576)506392139 
035 |a (DE-599)BSZ506392139 
035 |a (OCoLC)1341011768 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Heye, Tobias  |d 1976-  |e VerfasserIn  |0 (DE-588)133300943  |0 (DE-627)691326002  |0 (DE-576)271430303  |4 aut 
245 1 0 |a Evaluation of bowel peristalsis by dynamic cine MRI  |b detection of relevant functional disturbances - initial experience  |c Tobias Heye, MD, Daniel Stein, DSc, Dalibor Antolovic, MD, Margret Dueck, MD, Hans-Ulrich Kauczor, MD, and Waldemar Hosch, MD 
264 1 |c 2012 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published: 20 January 2012 
500 |a Gesehen am 15.06.2018 
520 |a Purpose: To investigate the diagnostic performance of a cine magnetic resonance imaging (MRI) sequence in the visualization and detection of impaired bowel peristalsis. Materials and Methods: In all, 91 consecutive patients (mean age 45 years) were prospectively examined on a 1.5 T system and stratified into a surgery group (n = 22) and a nonsurgery group (n = 69). A coronal fast imaging with steady-state precession (TrueFISP) sequence with 30 acquisitions per slice covered the abdomen in 10-15 slices each 7-12 mm thick (temporal resolution: 6-8 sec per frame). Image evaluation for reduced bowel peristalsis and relevant bowel stenosis was compared to surgical findings or clinical follow-up. Results: Cine MRI reached 96% accuracy (94% sensitivity; 100% specificity) in detecting a relevant reduction in bowel peristalsis and 85% of relevant stenosis was identified in the surgery group. Twenty of 69 patients of the nonsurgery group showed reduced peristalsis on cine MR which was attributed to underlying disease; 49/69 patients in this group had no findings on cine MR and were uneventfully followed up. Conclusion: Cine MRI of the bowel provides functional information of bowel passage. The visualization of a reduction in peristalsis may improve the assessment of the functional impact of suspected bowel adhesions or stenosis. Standard bowel MR protocols can be easily complemented by cine MR, extending scan time by <4 minutes. 
650 4 |a adhesion 
650 4 |a functional 
650 4 |a gastrointestinal tract 
650 4 |a magnetic resonance imaging 
650 4 |a stenosis 
700 1 |a Stein, Daniel  |d 1981-  |e VerfasserIn  |0 (DE-588)143477358  |0 (DE-627)646569325  |0 (DE-576)337277095  |4 aut 
700 1 |a Antolovič, Dalibor  |d 1971-  |e VerfasserIn  |0 (DE-588)128796197  |0 (DE-627)380637855  |0 (DE-576)297337491  |4 aut 
700 1 |a Dueck, Margret  |d 1954-  |e VerfasserIn  |0 (DE-588)123616646  |0 (DE-627)706369289  |0 (DE-576)293792275  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Hosch, Waldemar P.  |d 1969-  |e VerfasserIn  |0 (DE-588)11585696X  |0 (DE-627)691639205  |0 (DE-576)290116562  |4 aut 
773 0 8 |i Enthalten in  |t Journal of magnetic resonance imaging  |d New York, NY : Wiley-Liss, 1991  |g 35(2012), 4, Seite 859-867  |h Online-Ressource  |w (DE-627)306360039  |w (DE-600)1497154-9  |w (DE-576)114617252  |x 1522-2586  |7 nnas  |a Evaluation of bowel peristalsis by dynamic cine MRI detection of relevant functional disturbances - initial experience 
773 1 8 |g volume:35  |g year:2012  |g number:4  |g pages:859-867  |g extent:9  |a Evaluation of bowel peristalsis by dynamic cine MRI detection of relevant functional disturbances - initial experience 
856 4 0 |u http://dx.doi.org/10.1002/jmri.22851  |x Verlag  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.22851  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180615 
993 |a Article 
994 |a 2012 
998 |g 11585696X  |a Hosch, Waldemar P.  |m 11585696X:Hosch, Waldemar P.  |d 910000  |d 911400  |e 910000PH11585696X  |e 911400PH11585696X  |k 0/910000/  |k 1/910000/911400/  |p 6  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 123616646  |a Dueck, Margret  |m 123616646:Dueck, Margret  |d 910000  |d 910200  |e 910000PD123616646  |e 910200PD123616646  |k 0/910000/  |k 1/910000/910200/  |p 4 
998 |g 128796197  |a Antolovič, Dalibor  |m 128796197:Antolovič, Dalibor  |d 50000  |e 50000PA128796197  |k 0/50000/  |p 3 
998 |g 143477358  |a Stein, Daniel  |m 143477358:Stein, Daniel  |d 910000  |d 911400  |e 910000PS143477358  |e 911400PS143477358  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 133300943  |a Heye, Tobias  |m 133300943:Heye, Tobias  |d 910000  |d 911400  |e 910000PH133300943  |e 911400PH133300943  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1576392139  |e 3012722912 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2012"}],"person":[{"family":"Heye","role":"aut","given":"Tobias","display":"Heye, Tobias"},{"family":"Stein","role":"aut","given":"Daniel","display":"Stein, Daniel"},{"display":"Antolovič, Dalibor","family":"Antolovič","given":"Dalibor","role":"aut"},{"display":"Dueck, Margret","role":"aut","given":"Margret","family":"Dueck"},{"given":"Hans-Ulrich","role":"aut","family":"Kauczor","display":"Kauczor, Hans-Ulrich"},{"role":"aut","given":"Waldemar P.","family":"Hosch","display":"Hosch, Waldemar P."}],"relHost":[{"id":{"eki":["306360039"],"issn":["1522-2586"],"zdb":["1497154-9"],"doi":["10.1002/(ISSN)1522-2586"]},"part":{"year":"2012","volume":"35","pages":"859-867","text":"35(2012), 4, Seite 859-867","extent":"9","issue":"4"},"titleAlt":[{"title":"JMRI"}],"pubHistory":["1.1991 -"],"disp":"Evaluation of bowel peristalsis by dynamic cine MRI detection of relevant functional disturbances - initial experienceJournal of magnetic resonance imaging","physDesc":[{"extent":"Online-Ressource"}],"recId":"306360039","language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 28.02.08","Fortsetzung der CD-ROM-Ausgabe"],"title":[{"subtitle":"JMRI ; an official journal of the International Society for Magnetic Resonance in Medicine","title":"Journal of magnetic resonance imaging","title_sort":"Journal of magnetic resonance imaging"}],"origin":[{"publisher":"Wiley-Liss","dateIssuedKey":"1991","publisherPlace":"New York, NY","dateIssuedDisp":"1991-"}]}],"title":[{"title_sort":"Evaluation of bowel peristalsis by dynamic cine MRI","title":"Evaluation of bowel peristalsis by dynamic cine MRI","subtitle":"detection of relevant functional disturbances - initial experience"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"note":["First published: 20 January 2012","Gesehen am 15.06.2018"],"recId":"1576392139","physDesc":[{"extent":"9 S."}],"name":{"displayForm":["Tobias Heye, MD, Daniel Stein, DSc, Dalibor Antolovic, MD, Margret Dueck, MD, Hans-Ulrich Kauczor, MD, and Waldemar Hosch, MD"]},"id":{"doi":["10.1002/jmri.22851"],"eki":["1576392139"]}} 
SRT |a HEYETOBIASEVALUATION2012