PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging

Objectives: Dental MRI is often impaired by artefacts due to metallic dental materials. Several sequences were developed to reduce susceptibility artefacts. Here, we evaluated a set of sequences for artefact reduction for dental MRI for the first time.Methods: Artefact volume, signal-to-noise ratio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hilgenfeld, Tim (VerfasserIn) , Prager, Marcel (VerfasserIn) , Heil, Alexander (VerfasserIn) , Schwindling, Franz Sebastian (VerfasserIn) , Rammelsberg, Peter (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Heiland, Sabine (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2017
In: European radiology
Year: 2017, Jahrgang: 27, Heft: 12, Pages: 5104-5112
ISSN:1432-1084
DOI:10.1007/s00330-017-4901-1
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1007/s00330-017-4901-1
Verlag, Volltext: https://link.springer.com/article/10.1007/s00330-017-4901-1
Volltext
Verfasserangaben:Tim Hilgenfeld, Marcel Prager, Alexander Heil, Franz Sebastian Schwindling, Mathias Nittka, David Grodzki, Peter Rammelsberg, Martin Bendszus, Sabine Heiland

MARC

LEADER 00000caa a2200000 c 4500
001 1576730735
003 DE-627
005 20220814171520.0
007 cr uuu---uuuuu
008 180621s2017 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00330-017-4901-1  |2 doi 
035 |a (DE-627)1576730735 
035 |a (DE-576)506730735 
035 |a (DE-599)BSZ506730735 
035 |a (OCoLC)1341011821 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hilgenfeld, Tim  |d 1986-  |e VerfasserIn  |0 (DE-588)1106261917  |0 (DE-627)862954398  |0 (DE-576)473950316  |4 aut 
245 1 0 |a PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging  |c Tim Hilgenfeld, Marcel Prager, Alexander Heil, Franz Sebastian Schwindling, Mathias Nittka, David Grodzki, Peter Rammelsberg, Martin Bendszus, Sabine Heiland 
264 1 |c 2017 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First online: 11 July 2017 
500 |a Gesehen am 21.06.2018 
520 |a Objectives: Dental MRI is often impaired by artefacts due to metallic dental materials. Several sequences were developed to reduce susceptibility artefacts. Here, we evaluated a set of sequences for artefact reduction for dental MRI for the first time.Methods: Artefact volume, signal-to-noise ratio (SNR) and image quality were assessed on a 3-T MRI for pointwise encoding time reduction with radial acquisition (PETRA), multiple-slab acquisition with view angle tilting gradient, based on a sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) sequence (MSVAT-SPACE), slice-encoding for metal-artefact correction (SEMAC) and compared to a standard SPACE and a standard turbo-spin-echo (TSE) sequence. Field-of-view and acquisition times were chosen to enable in vivo application. Two implant-supported prostheses were tested (porcelain fused to metal non-precious alloy and monolithic zirconia). Results: Smallest artefact was measured for TSE sequences with no difference between the standard TSE and the SEMAC. MSVAT-SPACE reduced artefacts about 56% compared to the standard SPACE. Effect of the PETRA was dependent on sample used. Image quality and SNR were comparable for all sequences except PETRA, which yielded poor results. Conclusion: There is no benefit in terms of artefact reduction for SEMAC compared to standard TSE. Usage of MSVAT-SPACE is advantageous since artefacts are reduced and higher resolution is achieved. Key Points: SEMAC is not superior to TSE in terms of artefact reduction. MSVAT-SPACE reduces susceptibility artefacts while maintaining comparable image quality.PETRA reduces susceptibility artefacts depending on material but offers poor image quality 
700 1 |a Prager, Marcel  |e VerfasserIn  |0 (DE-588)1106261631  |0 (DE-627)86295357X  |0 (DE-576)473950030  |4 aut 
700 1 |a Heil, Alexander  |e VerfasserIn  |0 (DE-588)1137067721  |0 (DE-627)894042912  |0 (DE-576)491090668  |4 aut 
700 1 |a Schwindling, Franz Sebastian  |d 1986-  |e VerfasserIn  |0 (DE-588)1036843572  |0 (DE-627)751703613  |0 (DE-576)38697926X  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
773 0 8 |i Enthalten in  |t European radiology  |d Berlin : Springer, 1991  |g 27(2017), 12, Seite 5104-5112  |h Online-Ressource  |w (DE-627)268757526  |w (DE-600)1472718-3  |w (DE-576)103868070  |x 1432-1084  |7 nnas  |a PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging 
773 1 8 |g volume:27  |g year:2017  |g number:12  |g pages:5104-5112  |g extent:9  |a PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging 
856 4 0 |u http://dx.doi.org/10.1007/s00330-017-4901-1  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://link.springer.com/article/10.1007/s00330-017-4901-1  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180621 
993 |a Article 
994 |a 2017 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 9  |y j 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 8 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 7 
998 |g 1036843572  |a Schwindling, Franz Sebastian  |m 1036843572:Schwindling, Franz Sebastian  |d 910000  |d 910800  |e 910000PS1036843572  |e 910800PS1036843572  |k 0/910000/  |k 1/910000/910800/  |p 4 
998 |g 1137067721  |a Heil, Alexander  |m 1137067721:Heil, Alexander  |d 910000  |d 911100  |e 910000PH1137067721  |e 911100PH1137067721  |k 0/910000/  |k 1/910000/911100/  |p 3 
998 |g 1106261631  |a Prager, Marcel  |m 1106261631:Prager, Marcel  |d 910000  |d 911100  |e 910000PP1106261631  |e 911100PP1106261631  |k 0/910000/  |k 1/910000/911100/  |p 2 
998 |g 1106261917  |a Hilgenfeld, Tim  |m 1106261917:Hilgenfeld, Tim  |d 910000  |d 911100  |e 910000PH1106261917  |e 911100PH1106261917  |k 0/910000/  |k 1/910000/911100/  |p 1  |x j 
999 |a KXP-PPN1576730735  |e 3013321075 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"doi":["10.1007/s00330-017-4901-1"],"eki":["1576730735"]},"language":["eng"],"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"2017"}],"person":[{"role":"aut","family":"Hilgenfeld","display":"Hilgenfeld, Tim","given":"Tim"},{"given":"Marcel","display":"Prager, Marcel","family":"Prager","role":"aut"},{"given":"Alexander","family":"Heil","display":"Heil, Alexander","role":"aut"},{"role":"aut","given":"Franz Sebastian","family":"Schwindling","display":"Schwindling, Franz Sebastian"},{"given":"Peter","display":"Rammelsberg, Peter","family":"Rammelsberg","role":"aut"},{"role":"aut","given":"Martin","display":"Bendszus, Martin","family":"Bendszus"},{"given":"Sabine","display":"Heiland, Sabine","family":"Heiland","role":"aut"}],"title":[{"title_sort":"PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging","title":"PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging"}],"physDesc":[{"extent":"9 S."}],"relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"id":{"issn":["1432-1084","1613-3757"],"zdb":["1472718-3"],"eki":["268757526"]},"corporate":[{"role":"isb","display":"European Association of Radiology"}],"origin":[{"dateIssuedKey":"1991","publisher":"Springer","publisherPlace":"Berlin ; Heidelberg","dateIssuedDisp":"1991-"}],"part":{"volume":"27","text":"27(2017), 12, Seite 5104-5112","pages":"5104-5112","extent":"9","year":"2017","issue":"12"},"title":[{"subtitle":"official organ of the European Association of Radiology","title":"European radiology","title_sort":"European radiology"}],"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}],"physDesc":[{"extent":"Online-Ressource"}],"disp":"PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imagingEuropean radiology","recId":"268757526","pubHistory":["1.1991 -"],"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"]}],"name":{"displayForm":["Tim Hilgenfeld, Marcel Prager, Alexander Heil, Franz Sebastian Schwindling, Mathias Nittka, David Grodzki, Peter Rammelsberg, Martin Bendszus, Sabine Heiland"]},"recId":"1576730735","note":["First online: 11 July 2017","Gesehen am 21.06.2018"]} 
SRT |a HILGENFELDPETRAMSVAT2017