A vibrational technique for diagnosing loosened total hip endoprostheses: An experimental sawbone study
Aseptic loosening of hip implants is a severe orthopaedic problem and a valid diagnosis is often difficult. A potential method to determine loosening of the prosthesis is a swing analysis of the bone-implant interface using a vibrational technique. In this study, hip models were constructed to asses...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2013
|
| In: |
Medical engineering & physics
Year: 2013, Jahrgang: 35, Heft: 3, Pages: 329-337 |
| ISSN: | 1873-4030 |
| DOI: | 10.1016/j.medengphy.2012.05.007 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1016/j.medengphy.2012.05.007 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1350453312001270 |
| Verfasserangaben: | Johannes Sebastian Rieger, Sebastian Jaeger, Christian Schuld, Jan Philippe Kretzer, Rudi Georg Bitsch |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1576738663 | ||
| 003 | DE-627 | ||
| 005 | 20220814171723.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180621s2013 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.medengphy.2012.05.007 |2 doi | |
| 035 | |a (DE-627)1576738663 | ||
| 035 | |a (DE-576)506738663 | ||
| 035 | |a (DE-599)BSZ506738663 | ||
| 035 | |a (OCoLC)1341012105 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Rieger, Johannes Sebastian |d 1984- |e VerfasserIn |0 (DE-588)111862887X |0 (DE-627)872125459 |0 (DE-576)479541531 |4 aut | |
| 245 | 1 | 2 | |a A vibrational technique for diagnosing loosened total hip endoprostheses |b An experimental sawbone study |c Johannes Sebastian Rieger, Sebastian Jaeger, Christian Schuld, Jan Philippe Kretzer, Rudi Georg Bitsch |
| 264 | 1 | |c 2013 | |
| 300 | |a 9 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 4 June 2012 | ||
| 500 | |a Available online 4 June 2012 | ||
| 500 | |a Gesehen am 21.06.2018 | ||
| 520 | |a Aseptic loosening of hip implants is a severe orthopaedic problem and a valid diagnosis is often difficult. A potential method to determine loosening of the prosthesis is a swing analysis of the bone-implant interface using a vibrational technique. In this study, hip models were constructed to assess the vibration behaviour of the stem and cup components. Four different states of implant loosening were simulated: (1) stem and cup stable, (2) stem loosened and cup stable, (3) stem and cup loosened, and (4) stem stable and cup loosened. The model was excited at the lateral condyle of the femur between 100Hz and 2000Hz. Resonance spectra were recorded using an optical laser vibrometer and an accelerometer-based system. Analysis of the spectra revealed shifts of the resonances towards lower frequencies, especially in the case of a loosened stem component. The integral value of the spectra was a second parameter that was sensitive to a stem loosening. In the case of a loosened cup, a peak count analysis resulted in a significantly higher number of counts. In our model, different states of implant loosening could be determined with a vibrational technique and the localisation of the loosened component could be distinguished as well. | ||
| 650 | 4 | |a Endoprosthesis | |
| 650 | 4 | |a Hip joint | |
| 650 | 4 | |a Loosening | |
| 650 | 4 | |a Resonance shift | |
| 650 | 4 | |a Vibrational technique | |
| 700 | 1 | |a Jäger, Sebastian |d 1975- |e VerfasserIn |0 (DE-588)1059313731 |0 (DE-627)79828238X |0 (DE-576)415306647 |4 aut | |
| 700 | 1 | |a Schuld, Christian |e VerfasserIn |0 (DE-588)1035264773 |0 (DE-627)747112703 |0 (DE-576)382871928 |4 aut | |
| 700 | 1 | |a Kretzer, Jan Philippe |d 1978- |e VerfasserIn |0 (DE-588)136998348 |0 (DE-627)589003690 |0 (DE-576)301383103 |4 aut | |
| 700 | 1 | |a Bitsch, Rudi G. |d 1970- |e VerfasserIn |0 (DE-588)131490060 |0 (DE-627)50981378X |0 (DE-576)298541726 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Medical engineering & physics |d Amsterdam [u.a.] : Elsevier Science, 1994 |g 35(2013), 3, Seite 329-337 |h Online-Ressource |w (DE-627)320592332 |w (DE-600)2019106-6 |w (DE-576)259485039 |x 1873-4030 |7 nnas |a A vibrational technique for diagnosing loosened total hip endoprostheses An experimental sawbone study |
| 773 | 1 | 8 | |g volume:35 |g year:2013 |g number:3 |g pages:329-337 |g extent:9 |a A vibrational technique for diagnosing loosened total hip endoprostheses An experimental sawbone study |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.medengphy.2012.05.007 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S1350453312001270 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180621 | ||
| 993 | |a Article | ||
| 994 | |a 2013 | ||
| 998 | |g 131490060 |a Bitsch, Rudi G. |m 131490060:Bitsch, Rudi G. |d 910000 |d 911460 |d 50000 |e 910000PB131490060 |e 911460PB131490060 |e 50000PB131490060 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 5 |y j | ||
| 998 | |g 136998348 |a Kretzer, Jan Philippe |m 136998348:Kretzer, Jan Philippe |d 910000 |d 911460 |e 910000PK136998348 |e 911460PK136998348 |k 0/910000/ |k 1/910000/911460/ |p 4 | ||
| 998 | |g 1035264773 |a Schuld, Christian |m 1035264773:Schuld, Christian |d 910000 |d 911460 |e 910000PS1035264773 |e 911460PS1035264773 |k 0/910000/ |k 1/910000/911460/ |p 3 | ||
| 998 | |g 1059313731 |a Jäger, Sebastian |m 1059313731:Jäger, Sebastian |d 910000 |d 911460 |e 910000PJ1059313731 |e 911460PJ1059313731 |k 0/910000/ |k 1/910000/911460/ | ||
| 998 | |g 111862887X |a Rieger, Johannes Sebastian |m 111862887X:Rieger, Johannes Sebastian |d 910000 |d 911460 |e 910000PR111862887X |e 911460PR111862887X |k 0/910000/ |k 1/910000/911460/ |p 1 |x j | ||
| 999 | |a KXP-PPN1576738663 |e 3013334843 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"doi":["10.1016/j.medengphy.2012.05.007"],"eki":["1576738663"]},"physDesc":[{"extent":"9 S."}],"name":{"displayForm":["Johannes Sebastian Rieger, Sebastian Jaeger, Christian Schuld, Jan Philippe Kretzer, Rudi Georg Bitsch"]},"recId":"1576738663","relHost":[{"title":[{"title_sort":"Medical engineering & physics","subtitle":"official publication of the Institution of Physics and Engineering in Medicine (IPEM)","title":"Medical engineering & physics"}],"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1994","dateIssuedDisp":"1994-","publisherPlace":"Amsterdam [u.a.]"}],"pubHistory":["16.1994 -"],"note":["Gesehen am 19.12.2019","Fortsetzung der Druck-Ausgabe"],"disp":"A vibrational technique for diagnosing loosened total hip endoprostheses An experimental sawbone studyMedical engineering & physics","type":{"bibl":"periodical","media":"Online-Ressource"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"320592332","id":{"issn":["1873-4030"],"zdb":["2019106-6"],"eki":["320592332"]},"language":["eng"],"part":{"volume":"35","extent":"9","year":"2013","pages":"329-337","issue":"3","text":"35(2013), 3, Seite 329-337"}}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"vibrational technique for diagnosing loosened total hip endoprostheses","subtitle":"An experimental sawbone study","title":"A vibrational technique for diagnosing loosened total hip endoprostheses"}],"origin":[{"dateIssuedDisp":"2013","dateIssuedKey":"2013"}],"note":["Available online 4 June 2012","Available online 4 June 2012","Gesehen am 21.06.2018"],"language":["eng"],"person":[{"given":"Johannes Sebastian","role":"aut","display":"Rieger, Johannes Sebastian","family":"Rieger"},{"family":"Jäger","display":"Jäger, Sebastian","given":"Sebastian","role":"aut"},{"family":"Schuld","display":"Schuld, Christian","role":"aut","given":"Christian"},{"family":"Kretzer","display":"Kretzer, Jan Philippe","given":"Jan Philippe","role":"aut"},{"display":"Bitsch, Rudi G.","family":"Bitsch","given":"Rudi G.","role":"aut"}]} | ||
| SRT | |a RIEGERJOHAVIBRATIONA2013 | ||