Triple-rule-out dual-source CT angiography of patients with acute chest pain: dose reduction potential of 100 kV scanning

Purpose: To investigate the dose reduction potential of low kV triple-rule-out dual-source CT angiography (TRO-CTA) in non-obese (BMI ≤ 25 kg/m2) patients with acute chest pain. Materials and methods: Sixty consecutive patients were randomly assigned to two different retrospectively ECG-gated TRO-CT...

Full description

Saved in:
Bibliographic Details
Main Authors: Kriššák, Radko (Author) , Henzler, Thomas (Author) , Reichert, Miriam (Author) , Grüttner, Joachim (Author) , Süselbeck, Tim (Author) , Schönberg, Stefan (Author) , Fink, Christian (Author)
Format: Article (Journal)
Language:English
Published: 2012
In: European journal of radiology
Year: 2010, Volume: 81, Issue: 12, Pages: 3691-3696
ISSN:1872-7727
DOI:10.1016/j.ejrad.2010.11.021
Online Access:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1016/j.ejrad.2010.11.021
Verlag, kostenfrei, Volltext: https://www.ejradiology.com/article/S0720-048X(10)00575-9/abstract
Get full text
Author Notes:Radko Krissak, Thomas Henzler, Anne Prechel, Miriam Reichert, Joachim Gruettner, Tim Sueselbeck, Stefan O. Schoenberg, Christian Fink
Description
Summary:Purpose: To investigate the dose reduction potential of low kV triple-rule-out dual-source CT angiography (TRO-CTA) in non-obese (BMI ≤ 25 kg/m2) patients with acute chest pain. Materials and methods: Sixty consecutive patients were randomly assigned to two different retrospectively ECG-gated TRO-CTA protocols in this prospective trial: Thirty patients were examined with a 120-kV standard protocol (320 reference mAs with automatic tube current modulation, automatically adapted pitch and ECG-pulsing) and served as the control group (group 1), an otherwise identical 100 kV protocol was used in the other thirty patients (group 2) for a radiation dose reduction. Subjective image quality was assessed on a 5 point scale (1: excellent, 5: non-diagnostic) by two blinded observers. Quantitative image analysis assessed vascular attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in different vascular segments. The effective dose was calculated from the dose length product (DLP) using a conversion coefficient of 0.017 mSv mGy−1 cm−1. Results: There was no significant difference of age, BMI, heart rate, pitch or scan length between both patient groups. Subjective image quality was rated similar in both groups (group 1: 1.2 ± 0.4, group 2: average score = 1.3 ± 0.5). Vessel attenuation was significantly higher in group 2 than in group 1 (ascending aorta: 456 ± 83 HU vs. 370 ± 78 HU, p < 0.001; pulmonary artery: 468 ± 118 HU vs. 411 ± 91 HU, p = 0.03; left coronary artery: 437 ± 110 HU vs. 348 ± 89 HU, p < 0.001), however, there was no significant difference in SNR (13.2 ± 7.6 vs. 14.5 ± 7.5, p = 0.49) or CNR (13.8 ± 6.6 vs. 15.9 ± 7.7, p = 0.25). The effective radiation dose of the 100 kV protocol was significantly lower (9.6 ± 3.2 mSv vs. 18.1 ± 9.4 mSv, p < 0.0001). Conclusion: TRO-CTA with 100 kV is feasible in non-obese patients and results in diagnostic image quality and significantly reduced radiation dose.
Item Description:Available online 15 December 2010
Gesehen am 25.06.2018
Physical Description:Online Resource
ISSN:1872-7727
DOI:10.1016/j.ejrad.2010.11.021