Triple-rule-out dual-source CT angiography of patients with acute chest pain: dose reduction potential of 100 kV scanning
Purpose: To investigate the dose reduction potential of low kV triple-rule-out dual-source CT angiography (TRO-CTA) in non-obese (BMI ≤ 25 kg/m2) patients with acute chest pain. Materials and methods: Sixty consecutive patients were randomly assigned to two different retrospectively ECG-gated TRO-CT...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2012
|
| In: |
European journal of radiology
Year: 2010, Jahrgang: 81, Heft: 12, Pages: 3691-3696 |
| ISSN: | 1872-7727 |
| DOI: | 10.1016/j.ejrad.2010.11.021 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1016/j.ejrad.2010.11.021 Verlag, kostenfrei, Volltext: https://www.ejradiology.com/article/S0720-048X(10)00575-9/abstract |
| Verfasserangaben: | Radko Krissak, Thomas Henzler, Anne Prechel, Miriam Reichert, Joachim Gruettner, Tim Sueselbeck, Stefan O. Schoenberg, Christian Fink |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1576798461 | ||
| 003 | DE-627 | ||
| 005 | 20220814173053.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180625r20122010xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejrad.2010.11.021 |2 doi | |
| 035 | |a (DE-627)1576798461 | ||
| 035 | |a (DE-576)506798461 | ||
| 035 | |a (DE-599)BSZ506798461 | ||
| 035 | |a (OCoLC)1341012119 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Kriššák, Radko |d 1980- |e VerfasserIn |0 (DE-588)133904091 |0 (DE-627)557959128 |0 (DE-576)276900936 |4 aut | |
| 245 | 1 | 0 | |a Triple-rule-out dual-source CT angiography of patients with acute chest pain |b dose reduction potential of 100 kV scanning |c Radko Krissak, Thomas Henzler, Anne Prechel, Miriam Reichert, Joachim Gruettner, Tim Sueselbeck, Stefan O. Schoenberg, Christian Fink |
| 264 | 1 | |c 2012 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 15 December 2010 | ||
| 500 | |a Gesehen am 25.06.2018 | ||
| 520 | |a Purpose: To investigate the dose reduction potential of low kV triple-rule-out dual-source CT angiography (TRO-CTA) in non-obese (BMI ≤ 25 kg/m2) patients with acute chest pain. Materials and methods: Sixty consecutive patients were randomly assigned to two different retrospectively ECG-gated TRO-CTA protocols in this prospective trial: Thirty patients were examined with a 120-kV standard protocol (320 reference mAs with automatic tube current modulation, automatically adapted pitch and ECG-pulsing) and served as the control group (group 1), an otherwise identical 100 kV protocol was used in the other thirty patients (group 2) for a radiation dose reduction. Subjective image quality was assessed on a 5 point scale (1: excellent, 5: non-diagnostic) by two blinded observers. Quantitative image analysis assessed vascular attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in different vascular segments. The effective dose was calculated from the dose length product (DLP) using a conversion coefficient of 0.017 mSv mGy−1 cm−1. Results: There was no significant difference of age, BMI, heart rate, pitch or scan length between both patient groups. Subjective image quality was rated similar in both groups (group 1: 1.2 ± 0.4, group 2: average score = 1.3 ± 0.5). Vessel attenuation was significantly higher in group 2 than in group 1 (ascending aorta: 456 ± 83 HU vs. 370 ± 78 HU, p < 0.001; pulmonary artery: 468 ± 118 HU vs. 411 ± 91 HU, p = 0.03; left coronary artery: 437 ± 110 HU vs. 348 ± 89 HU, p < 0.001), however, there was no significant difference in SNR (13.2 ± 7.6 vs. 14.5 ± 7.5, p = 0.49) or CNR (13.8 ± 6.6 vs. 15.9 ± 7.7, p = 0.25). The effective radiation dose of the 100 kV protocol was significantly lower (9.6 ± 3.2 mSv vs. 18.1 ± 9.4 mSv, p < 0.0001). Conclusion: TRO-CTA with 100 kV is feasible in non-obese patients and results in diagnostic image quality and significantly reduced radiation dose. | ||
| 534 | |c 2010 | ||
| 650 | 4 | |a Chest pain | |
| 650 | 4 | |a Computed tomography | |
| 650 | 4 | |a Low kilovoltage | |
| 650 | 4 | |a Radiation dose | |
| 650 | 4 | |a Triple rule out | |
| 700 | 1 | |a Henzler, Thomas |d 1980- |e VerfasserIn |0 (DE-588)134001486 |0 (DE-627)559468415 |0 (DE-576)276829948 |4 aut | |
| 700 | 1 | |a Reichert, Miriam |d 1981- |e VerfasserIn |0 (DE-588)1030116652 |0 (DE-627)734811292 |0 (DE-576)377924830 |4 aut | |
| 700 | 1 | |a Grüttner, Joachim |e VerfasserIn |0 (DE-588)1028328303 |0 (DE-627)730570207 |0 (DE-576)375815619 |4 aut | |
| 700 | 1 | |a Süselbeck, Tim |d 1965- |e VerfasserIn |0 (DE-588)1025318765 |0 (DE-627)722056184 |0 (DE-576)370207181 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Fink, Christian |d 1971- |e VerfasserIn |0 (DE-588)121198014 |0 (DE-627)705299767 |0 (DE-576)292581882 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t European journal of radiology |d Amsterdam [u.a.] : Elsevier Science, 1990 |g 81(2012), 12, Seite 3691-3696 |h Online-Ressource |w (DE-627)32044483X |w (DE-600)2005350-2 |w (DE-576)099718138 |x 1872-7727 |7 nnas |a Triple-rule-out dual-source CT angiography of patients with acute chest pain dose reduction potential of 100 kV scanning |
| 773 | 1 | 8 | |g volume:81 |g year:2012 |g number:12 |g pages:3691-3696 |g extent:6 |a Triple-rule-out dual-source CT angiography of patients with acute chest pain dose reduction potential of 100 kV scanning |
| 776 | 0 | 8 | |i Erscheint auch als |n Druck-Ausgabe |t Triple-rule-out dual-source CT angiography of patients with acute chest pain |d 2012 |w (DE-627)1447921518 |w (DE-576)377921513 |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.ejrad.2010.11.021 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://www.ejradiology.com/article/S0720-048X(10)00575-9/abstract |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180625 | ||
| 993 | |a Article | ||
| 994 | |a 2012 | ||
| 998 | |g 121198014 |a Fink, Christian |m 121198014:Fink, Christian |d 60000 |d 62900 |e 60000PF121198014 |e 62900PF121198014 |k 0/60000/ |k 1/60000/62900/ |p 8 |y j | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 7 | ||
| 998 | |g 1025318765 |a Süselbeck, Tim |m 1025318765:Süselbeck, Tim |d 60000 |d 61000 |e 60000PS1025318765 |e 61000PS1025318765 |k 0/60000/ |k 1/60000/61000/ |p 6 | ||
| 998 | |g 1028328303 |a Grüttner, Joachim |m 1028328303:Grüttner, Joachim |d 60000 |d 61000 |e 60000PG1028328303 |e 61000PG1028328303 |k 0/60000/ |k 1/60000/61000/ |p 5 | ||
| 998 | |g 1030116652 |a Reichert, Miriam |m 1030116652:Reichert, Miriam |d 60000 |d 62900 |e 60000PR1030116652 |e 62900PR1030116652 |k 0/60000/ |k 1/60000/62900/ |p 4 | ||
| 998 | |g 134001486 |a Henzler, Thomas |m 134001486:Henzler, Thomas |d 60000 |e 60000PH134001486 |k 0/60000/ |p 2 | ||
| 998 | |g 133904091 |a Kriššák, Radko |m 133904091:Kriššák, Radko |d 60000 |d 62900 |e 60000PK133904091 |e 62900PK133904091 |k 0/60000/ |k 1/60000/62900/ |p 1 |x j | ||
| 999 | |a KXP-PPN1576798461 |e 3013577304 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Available online 15 December 2010","Gesehen am 25.06.2018"],"title":[{"subtitle":"dose reduction potential of 100 kV scanning","title":"Triple-rule-out dual-source CT angiography of patients with acute chest pain","title_sort":"Triple-rule-out dual-source CT angiography of patients with acute chest pain"}],"person":[{"roleDisplay":"VerfasserIn","family":"Kriššák","display":"Kriššák, Radko","given":"Radko","role":"aut"},{"given":"Thomas","role":"aut","roleDisplay":"VerfasserIn","display":"Henzler, Thomas","family":"Henzler"},{"role":"aut","given":"Miriam","roleDisplay":"VerfasserIn","family":"Reichert","display":"Reichert, Miriam"},{"family":"Grüttner","display":"Grüttner, Joachim","roleDisplay":"VerfasserIn","role":"aut","given":"Joachim"},{"given":"Tim","role":"aut","display":"Süselbeck, Tim","family":"Süselbeck","roleDisplay":"VerfasserIn"},{"role":"aut","given":"Stefan","display":"Schönberg, Stefan","family":"Schönberg","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","display":"Fink, Christian","family":"Fink","role":"aut","given":"Christian"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"id":{"eki":["1576798461"],"doi":["10.1016/j.ejrad.2010.11.021"]},"physDesc":[{"extent":"6 S."}],"recId":"1576798461","name":{"displayForm":["Radko Krissak, Thomas Henzler, Anne Prechel, Miriam Reichert, Joachim Gruettner, Tim Sueselbeck, Stefan O. Schoenberg, Christian Fink"]},"relHost":[{"language":["eng"],"id":{"eki":["32044483X"],"zdb":["2005350-2"],"issn":["1872-7727"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"32044483X","titleAlt":[{"title":"EJR"}],"note":["Gesehen am 05.02.20"],"title":[{"title_sort":"European journal of radiology","title":"European journal of radiology","subtitle":"EJR"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"publisher":"Elsevier Science","dateIssuedDisp":"1990-","publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1990"}],"disp":"Triple-rule-out dual-source CT angiography of patients with acute chest pain dose reduction potential of 100 kV scanningEuropean journal of radiology","pubHistory":["Nachgewiesen 10.1990 -"],"part":{"volume":"81","pages":"3691-3696","year":"2012","issue":"12","extent":"6","text":"81(2012), 12, Seite 3691-3696"}}],"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2012"}]} | ||
| SRT | |a KRISSAKRADTRIPLERULE2012 | ||