Precision IORT - image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correction

Background: To the present date, IORT has been eye and hand guided without treatment planning and tissue heterogeneity correction. This limits the precision of the application and the precise documentation of the location and the deposited dose in the tissue. Here we present a set-up where we use im...

Full description

Saved in:
Bibliographic Details
Main Authors: Schneider, Frank (Author) , Bludau, Frederic (Author) , Clausen, Sven (Author) , Fleckenstein, Jens (Author) , Obertacke, Udo (Author) , Wenz, Frederik (Author)
Format: Article (Journal)
Language:English
Published: 2017
In: Physica medica
Year: 2017, Volume: 37, Pages: 82-87
ISSN:1724-191X
DOI:10.1016/j.ejmp.2017.04.017
Online Access:Verlag, Volltext: http://dx.doi.org/10.1016/j.ejmp.2017.04.017
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1120179717301035
Get full text
Author Notes:Frank Schneider, Frederic Bludau, Sven Clausen, Jens Fleckenstein, Udo Obertacke, Frederik Wenz

MARC

LEADER 00000caa a2200000 c 4500
001 1576823563
003 DE-627
005 20220814173737.0
007 cr uuu---uuuuu
008 180625s2017 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejmp.2017.04.017  |2 doi 
035 |a (DE-627)1576823563 
035 |a (DE-576)506823563 
035 |a (DE-599)BSZ506823563 
035 |a (OCoLC)1341012475 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schneider, Frank  |d 1980-  |e VerfasserIn  |0 (DE-588)14139093X  |0 (DE-627)627292321  |0 (DE-576)323515576  |4 aut 
245 1 0 |a Precision IORT - image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correction  |c Frank Schneider, Frederic Bludau, Sven Clausen, Jens Fleckenstein, Udo Obertacke, Frederik Wenz 
264 1 |c 2017 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 28 April 2017 
500 |a Gesehen am 25.06.2018 
520 |a Background: To the present date, IORT has been eye and hand guided without treatment planning and tissue heterogeneity correction. This limits the precision of the application and the precise documentation of the location and the deposited dose in the tissue. Here we present a set-up where we use image guidance by intraoperative cone beam computed tomography (CBCT) for precise online Monte Carlo treatment planning including tissue heterogeneity correction. Materials and methods: An IORT was performed during balloon kyphoplasty using a dedicated Needle Applicator. An intraoperative CBCT was registered with a pre-op CT. Treatment planning was performed in Radiance using a hybrid Monte Carlo algorithm simulating dose in homogeneous (MCwater) and heterogeneous medium (MChet). Dose distributions on CBCT and pre-op CT were compared with each other. Spinal cord and the metastasis doses were evaluated. Results: The MCwater calculations showed a spherical dose distribution as expected. The minimum target dose for the MChet simulations on pre-op CT was increased by 40% while the maximum spinal cord dose was decreased by 35%. Due to the artefacts on the CBCT the comparison between MChet simulations on CBCT and pre-op CT showed differences up to 50% in dose. Conclusions: igIORT and online treatment planning improves the accuracy of IORT. However, the current set-up is limited by CT artefacts. Fusing an intraoperative CBCT with a pre-op CT allows the combination of an accurate dose calculation with the knowledge of the correct source/applicator position. This method can be also used for pre-operative treatment planning followed by image guided surgery. 
650 4 |a Intrabeam 
650 4 |a Intraoperative radiotherapy 
650 4 |a Kypho IORT 
650 4 |a Radiance 
650 4 |a Treatment planning 
700 1 |a Bludau, Frederic  |d 1981-  |e VerfasserIn  |0 (DE-588)1019241691  |0 (DE-627)716981432  |0 (DE-576)365495026  |4 aut 
700 1 |a Clausen, Sven  |d 1983-  |e VerfasserIn  |0 (DE-588)1029118787  |0 (DE-627)732476437  |0 (DE-576)376583894  |4 aut 
700 1 |a Fleckenstein, Jens  |d 1981-  |e VerfasserIn  |0 (DE-588)102911918X  |0 (DE-627)732477212  |0 (DE-576)376584599  |4 aut 
700 1 |a Obertacke, Udo  |d 1957-  |e VerfasserIn  |0 (DE-588)1034338978  |0 (DE-627)745232590  |0 (DE-576)381955672  |4 aut 
700 1 |a Wenz, Frederik  |d 1966-  |e VerfasserIn  |0 (DE-588)113310390  |0 (DE-627)663837766  |0 (DE-576)346656281  |4 aut 
773 0 8 |i Enthalten in  |t Physica medica  |d Amsterdam : Elsevier, 1996  |g 37(2017), Seite 82-87  |h Online-Ressource  |w (DE-627)364471417  |w (DE-600)2110535-2  |w (DE-576)272350176  |x 1724-191X  |7 nnas  |a Precision IORT - image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correction 
773 1 8 |g volume:37  |g year:2017  |g pages:82-87  |g extent:6  |a Precision IORT - image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correction 
856 4 0 |u http://dx.doi.org/10.1016/j.ejmp.2017.04.017  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1120179717301035  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180625 
993 |a Article 
994 |a 2017 
998 |g 113310390  |a Wenz, Frederik  |m 113310390:Wenz, Frederik  |d 60000  |d 63000  |e 60000PW113310390  |e 63000PW113310390  |k 0/60000/  |k 1/60000/63000/  |p 6  |y j 
998 |g 1034338978  |a Obertacke, Udo  |m 1034338978:Obertacke, Udo  |d 60000  |d 62400  |e 60000PO1034338978  |e 62400PO1034338978  |k 0/60000/  |k 1/60000/62400/  |p 5 
998 |g 102911918X  |a Fleckenstein, Jens  |m 102911918X:Fleckenstein, Jens  |d 60000  |d 63000  |e 60000PF102911918X  |e 63000PF102911918X  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 1029118787  |a Clausen, Sven  |m 1029118787:Clausen, Sven  |d 60000  |d 63000  |e 60000PC1029118787  |e 63000PC1029118787  |k 0/60000/  |k 1/60000/63000/  |p 3 
998 |g 1019241691  |a Bludau, Frederic  |m 1019241691:Bludau, Frederic  |d 60000  |d 62400  |e 60000PB1019241691  |e 62400PB1019241691  |k 0/60000/  |k 1/60000/62400/  |p 2 
998 |g 14139093X  |a Schneider, Frank  |m 14139093X:Schneider, Frank  |d 60000  |d 63000  |e 60000PS14139093X  |e 63000PS14139093X  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN1576823563  |e 3013705175 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedDisp":"2017","dateIssuedKey":"2017"}],"id":{"eki":["1576823563"],"doi":["10.1016/j.ejmp.2017.04.017"]},"recId":"1576823563","physDesc":[{"extent":"6 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Available online 28 April 2017","Gesehen am 25.06.2018"],"language":["eng"],"relHost":[{"title":[{"subtitle":"European journal of medical physics ; an international journal devoted to the applications of physics to medicine and biology","title_sort":"Physica medica","title":"Physica medica"}],"note":["Frühere Jahrgänge online nicht mehr verfügbar","Fortsetzung der Druck-Ausgabe","Gesehen am 06.03.2026"],"part":{"volume":"37","extent":"6","pages":"82-87","year":"2017","text":"37(2017), Seite 82-87"},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2110535-2"],"issn":["1724-191X"],"eki":["364471417"]},"origin":[{"dateIssuedKey":"1996","publisherPlace":"Amsterdam ; Pisa","publisher":"Elsevier ; Istituti Editoriali e Poligrafici Internazionali","dateIssuedDisp":"1996-"}],"disp":"Precision IORT - image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correctionPhysica medica","pubHistory":["Nachgewiesen 12.1996 -"],"recId":"364471417"}],"name":{"displayForm":["Frank Schneider, Frederic Bludau, Sven Clausen, Jens Fleckenstein, Udo Obertacke, Frederik Wenz"]},"title":[{"title_sort":"Precision IORT - image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correction","title":"Precision IORT - image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correction"}],"person":[{"family":"Schneider","display":"Schneider, Frank","role":"aut","given":"Frank"},{"family":"Bludau","role":"aut","display":"Bludau, Frederic","given":"Frederic"},{"role":"aut","display":"Clausen, Sven","family":"Clausen","given":"Sven"},{"role":"aut","display":"Fleckenstein, Jens","family":"Fleckenstein","given":"Jens"},{"family":"Obertacke","role":"aut","display":"Obertacke, Udo","given":"Udo"},{"role":"aut","display":"Wenz, Frederik","family":"Wenz","given":"Frederik"}]} 
SRT |a SCHNEIDERFPRECISIONI2017