Image quality of two different mobile cone beam computed tomographs for maxillofacial surgery

Purpose: We evaluated two mobile cone beam computed tomographs (mCBCT) comparing image quality with respect to radiation dosage. Image quality was analyzed by using different scanning modes. Materials and methods. The skulls of three human cadavers were scanned by use of conventional Computed Tomogr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Seeberger, Robin (VerfasserIn) , Seethaler, Andreas Christian (VerfasserIn) , Hoffmann, Jürgen (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2012
In: Journal of cranio-maxillofacial surgery
Year: 2012, Jahrgang: 40, Heft: 8, Pages: 731-734
ISSN:1878-4119
DOI:10.1016/j.jcms.2012.01.008
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.jcms.2012.01.008
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1010518212000224
Volltext
Verfasserangaben:Robin Seeberger, Markus Buchgeister, Andreas C. Seethaler, Thomas Shiozawa, Juergen Hoffmann

MARC

LEADER 00000caa a2200000 c 4500
001 1576874605
003 DE-627
005 20240316100447.0
007 cr uuu---uuuuu
008 180626s2012 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jcms.2012.01.008  |2 doi 
035 |a (DE-627)1576874605 
035 |a (DE-576)506874605 
035 |a (DE-599)BSZ506874605 
035 |a (OCoLC)1341012936 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Seeberger, Robin  |d 1976-  |e VerfasserIn  |0 (DE-588)136014216  |0 (DE-627)574409211  |0 (DE-576)300779240  |4 aut 
245 1 0 |a Image quality of two different mobile cone beam computed tomographs for maxillofacial surgery  |c Robin Seeberger, Markus Buchgeister, Andreas C. Seethaler, Thomas Shiozawa, Juergen Hoffmann 
264 1 |c 2012 
300 |a 4 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 21 February 2012 
500 |a Gesehen am 26.06.2018 
520 |a Purpose: We evaluated two mobile cone beam computed tomographs (mCBCT) comparing image quality with respect to radiation dosage. Image quality was analyzed by using different scanning modes. Materials and methods. The skulls of three human cadavers were scanned by use of conventional Computed Tomography (CT) as well as with two mobile cone beam computed tomographs (Siemens Arcadis Orbic 3D and ZiehmVision Vario 3D). Six different acquisition modes with different radiation dosages were used. The axial views of all scans were evaluated by five medical doctors regarding image quality by identifying predefined anatomical structures of the skull. A five-point ranking scale was used. The inter-rater reliability was statistically depicted by Cohen’s Kappa coefficient. A Wilcoxon signed rank test was used to evaluate the rater’s results. For evaluating the signal-to-noise ratio (SNR) a Catphan 600 reference body with two different inlays was used. Results: Comparing the mCBCTs, the image quality of the Siemens Arcadis Orbic 3D in high-dosage mode received the best score (median: 2.27). The inter-rater reliability was fair (Kappa=−0.030 to 0.328). The Wilcoxon test showed significant (p<0.05) different median rating values in 18 out of 21 imaging modes. The SNR was higher (better) in the high-dosage modes. Conclusion:Intra-operative 3D imaging by using mCBCT for maxillofacial surgery in low-dose mode acquisition is adequate in terms of signal-to-noise ratio and image quality. The image quality does not correlate in a linear manner with a higher radiation dosage. Surgeons using this technique should gather their own experience with the different acquisition modes. 
650 4 |a C-arm 
650 4 |a Intra-operative imaging 
650 4 |a Maxillofacial 
650 4 |a Mobile CBCT 
700 1 |a Seethaler, Andreas Christian  |d 1981-  |e VerfasserIn  |0 (DE-588)141463538  |0 (DE-627)627798454  |0 (DE-576)323995918  |4 aut 
700 1 |a Hoffmann, Jürgen  |d 1965-  |e VerfasserIn  |0 (DE-588)1032524456  |0 (DE-627)738520063  |0 (DE-576)380087189  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cranio-maxillofacial surgery  |d Oxford [u.a.] : Elsevier, 1987  |g 40(2012), 8, Seite 731-734  |h Online-Ressource  |w (DE-627)320479218  |w (DE-600)2009565-X  |w (DE-576)10374696X  |x 1878-4119  |7 nnas  |a Image quality of two different mobile cone beam computed tomographs for maxillofacial surgery 
773 1 8 |g volume:40  |g year:2012  |g number:8  |g pages:731-734  |g extent:4  |a Image quality of two different mobile cone beam computed tomographs for maxillofacial surgery 
856 4 0 |u http://dx.doi.org/10.1016/j.jcms.2012.01.008  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1010518212000224  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180626 
993 |a Article 
994 |a 2012 
998 |g 1032524456  |a Hoffmann, Jürgen  |m 1032524456:Hoffmann, Jürgen  |d 910000  |d 910800  |e 910000PH1032524456  |e 910800PH1032524456  |k 0/910000/  |k 1/910000/910800/  |p 5  |y j 
998 |g 141463538  |a Seethaler, Andreas Christian  |m 141463538:Seethaler, Andreas Christian  |d 910000  |d 910800  |e 910000PS141463538  |e 910800PS141463538  |k 0/910000/  |k 1/910000/910800/  |p 3 
998 |g 136014216  |a Seeberger, Robin  |m 136014216:Seeberger, Robin  |d 50000  |e 50000PS136014216  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1576874605  |e 3013843128 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"physDesc":[{"extent":"4 S."}],"title":[{"title_sort":"Image quality of two different mobile cone beam computed tomographs for maxillofacial surgery","title":"Image quality of two different mobile cone beam computed tomographs for maxillofacial surgery"}],"person":[{"family":"Seeberger","role":"aut","given":"Robin","display":"Seeberger, Robin"},{"family":"Seethaler","role":"aut","given":"Andreas Christian","display":"Seethaler, Andreas Christian"},{"family":"Hoffmann","given":"Jürgen","role":"aut","display":"Hoffmann, Jürgen"}],"recId":"1576874605","name":{"displayForm":["Robin Seeberger, Markus Buchgeister, Andreas C. Seethaler, Thomas Shiozawa, Juergen Hoffmann"]},"origin":[{"dateIssuedDisp":"2012","dateIssuedKey":"2012"}],"id":{"eki":["1576874605"],"doi":["10.1016/j.jcms.2012.01.008"]},"note":["Available online 21 February 2012","Gesehen am 26.06.2018"],"relHost":[{"title":[{"title":"Journal of cranio-maxillofacial surgery","subtitle":"official publication of the European Association for Cranio-Maxillofacial Surgery","title_sort":"Journal of cranio-maxillofacial surgery"}],"note":["Gesehen am 11.06.18"],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["Nachgewiesen 15.1987 -"],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"Oxford [u.a.] ; Edinburgh [u.a.]","dateIssuedDisp":"1987-","publisher":"Elsevier ; Churchill Livingstone","dateIssuedKey":"1987"}],"id":{"eki":["320479218"],"issn":["1878-4119"],"zdb":["2009565-X"]},"part":{"issue":"8","year":"2012","pages":"731-734","volume":"40","extent":"4","text":"40(2012), 8, Seite 731-734"},"recId":"320479218","disp":"Image quality of two different mobile cone beam computed tomographs for maxillofacial surgeryJournal of cranio-maxillofacial surgery"}]} 
SRT |a SEEBERGERRIMAGEQUALI2012