Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm: initial patient experience

OBJECTIVE: To evaluate the effect of a temporal resolution improvement method (TRIM) for cardiac CT on diagnostic image quality for coronary artery assessment. MATERIALS AND METHODS: The TRIM-algorithm employs an iterative approach to reconstruct images from less than 180° of projections and uses a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Apfaltrer, Paul (VerfasserIn) , Henzler, Thomas (VerfasserIn) , Fink, Christian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2013
In: European journal of radiology
Year: 2012, Jahrgang: 82, Heft: 2, Pages: 270-274
ISSN:1872-7727
DOI:10.1016/j.ejrad.2012.10.005
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.ejrad.2012.10.005
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X12004846
Volltext
Verfasserangaben:Paul Apfaltrer, Harald Schoendube, U. Joseph Schoepf, Thomas Allmendinger, Francesco Tricarico, Andreas Schindler, Sebastian Vogt, Johan Sunnegårdh, Karl Stierstorfer, Thomas Henzler, Christian Fink, Herbert Bruder, Thomas G. Flohr, Ullrich Ebersberger

MARC

LEADER 00000caa a2200000 c 4500
001 1576951812
003 DE-627
005 20220814180759.0
007 cr uuu---uuuuu
008 180628r20132012xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2012.10.005  |2 doi 
035 |a (DE-627)1576951812 
035 |a (DE-576)506951812 
035 |a (DE-599)BSZ506951812 
035 |a (OCoLC)1341013024 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Apfaltrer, Paul  |d 1983-  |e VerfasserIn  |0 (DE-588)1025309898  |0 (DE-627)722024924  |0 (DE-576)370191757  |4 aut 
245 1 0 |a Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm  |b initial patient experience  |c Paul Apfaltrer, Harald Schoendube, U. Joseph Schoepf, Thomas Allmendinger, Francesco Tricarico, Andreas Schindler, Sebastian Vogt, Johan Sunnegårdh, Karl Stierstorfer, Thomas Henzler, Christian Fink, Herbert Bruder, Thomas G. Flohr, Ullrich Ebersberger 
264 1 |c 2013 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 5 November 2012 
500 |a Gesehen am 28.06.2018 
520 |a OBJECTIVE: To evaluate the effect of a temporal resolution improvement method (TRIM) for cardiac CT on diagnostic image quality for coronary artery assessment. MATERIALS AND METHODS: The TRIM-algorithm employs an iterative approach to reconstruct images from less than 180° of projections and uses a histogram constraint to prevent the occurrence of limited-angle artifacts. This algorithm was applied in 11 obese patients (7 men, 67.2 ± 9.8 years) who had undergone second generation dual-source cardiac CT with 120 kV, 175-426 mAs, and 500 ms gantry rotation. All data were reconstructed with a temporal resolution of 250 ms using traditional filtered-back projection (FBP) and of 200 ms using the TRIM-algorithm. Contrast attenuation and contrast-to-noise-ratio (CNR) were measured in the ascending aorta. The presence and severity of coronary motion artifacts was rated on a 4-point Likert scale. RESULTS: All scans were considered of diagnostic quality. Mean BMI was 36 ± 3.6 kg/m(2). Average heart rate was 60 ± 9 bpm. Mean effective dose was 13.5 ± 4.6 mSv. When comparing FBP- and TRIM reconstructed series, the attenuation within the ascending aorta (392 ± 70.7 vs. 396.8 ± 70.1 HU, p>0.05) and CNR (13.2 ± 3.2 vs. 11.7 ± 3.1, p>0.05) were not significantly different. A total of 110 coronary segments were evaluated. All studies were deemed diagnostic; however, there was a significant (p<0.05) difference in the severity score distribution of coronary motion artifacts between FBP (median=2.5) and TRIM (median=2.0) reconstructions. CONCLUSION: The algorithm evaluated here delivers diagnostic imaging quality of the coronary arteries despite 500 ms gantry rotation. Possible applications include improvement of cardiac imaging on slower gantry rotation systems or mitigation of the trade-off between temporal resolution and CNR in obese patients. 
534 |c 2012 
650 4 |a Aged 
650 4 |a Algorithms 
650 4 |a Coronary Angiography 
650 4 |a Coronary Artery Disease 
650 4 |a Female 
650 4 |a Humans 
650 4 |a Male 
650 4 |a Pilot Projects 
650 4 |a Radiographic Image Enhancement 
650 4 |a Radiographic Image Interpretation, Computer-Assisted 
650 4 |a Reproducibility of Results 
650 4 |a Sensitivity and Specificity 
650 4 |a Tomography, X-Ray Computed 
700 1 |a Henzler, Thomas  |d 1980-  |e VerfasserIn  |0 (DE-588)134001486  |0 (DE-627)559468415  |0 (DE-576)276829948  |4 aut 
700 1 |a Fink, Christian  |d 1971-  |e VerfasserIn  |0 (DE-588)121198014  |0 (DE-627)705299767  |0 (DE-576)292581882  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 82(2013), 2, Seite 270-274  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm initial patient experience 
773 1 8 |g volume:82  |g year:2013  |g number:2  |g pages:270-274  |g extent:5  |a Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm initial patient experience 
776 0 8 |i Erscheint auch als  |n Druck-Ausgabe  |a Apfaltrer, Paul, 1983 -   |t Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm  |d 2013  |w (DE-627)1449715842  |w (DE-576)379715848 
856 4 0 |u http://dx.doi.org/10.1016/j.ejrad.2012.10.005  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0720048X12004846  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180628 
993 |a Article 
994 |a 2013 
998 |g 121198014  |a Fink, Christian  |m 121198014:Fink, Christian  |d 60000  |d 62900  |e 60000PF121198014  |e 62900PF121198014  |k 0/60000/  |k 1/60000/62900/  |p 11 
998 |g 134001486  |a Henzler, Thomas  |m 134001486:Henzler, Thomas  |d 60000  |e 60000PH134001486  |k 0/60000/  |p 10 
998 |g 1025309898  |a Apfaltrer, Paul  |m 1025309898:Apfaltrer, Paul  |d 60000  |d 62900  |e 60000PA1025309898  |e 62900PA1025309898  |k 0/60000/  |k 1/60000/62900/  |p 1  |x j 
999 |a KXP-PPN1576951812  |e 3014641405 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Available online 5 November 2012","Gesehen am 28.06.2018"],"relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["Nachgewiesen 10.1990 -"],"disp":"Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm initial patient experienceEuropean journal of radiology","recId":"32044483X","titleAlt":[{"title":"EJR"}],"language":["eng"],"part":{"issue":"2","extent":"5","pages":"270-274","year":"2013","volume":"82","text":"82(2013), 2, Seite 270-274"},"id":{"eki":["32044483X"],"zdb":["2005350-2"],"issn":["1872-7727"]},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 05.02.20"],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1990","dateIssuedDisp":"1990-","publisher":"Elsevier Science"}],"title":[{"title":"European journal of radiology","subtitle":"EJR","title_sort":"European journal of radiology"}]}],"id":{"doi":["10.1016/j.ejrad.2012.10.005"],"eki":["1576951812"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"5 S."}],"title":[{"title":"Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm","subtitle":"initial patient experience","title_sort":"Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm"}],"language":["eng"],"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"2013"}],"name":{"displayForm":["Paul Apfaltrer, Harald Schoendube, U. Joseph Schoepf, Thomas Allmendinger, Francesco Tricarico, Andreas Schindler, Sebastian Vogt, Johan Sunnegårdh, Karl Stierstorfer, Thomas Henzler, Christian Fink, Herbert Bruder, Thomas G. Flohr, Ullrich Ebersberger"]},"recId":"1576951812","person":[{"family":"Apfaltrer","display":"Apfaltrer, Paul","given":"Paul","role":"aut"},{"role":"aut","display":"Henzler, Thomas","given":"Thomas","family":"Henzler"},{"given":"Christian","display":"Fink, Christian","family":"Fink","role":"aut"}]} 
SRT |a APFALTRERPENHANCEDTE2013