Impact on image quality and radiation dose of third-generation dual-source computed tomography of the coronary arteries
The aim of this study was to assess the image quality (IQ) and radiation dose of third-generation dual-source computed tomography (CT) coronary angiography (cCTA) in comparison with 64-slice single-source CT. This retrospective study included 140 patients (73 men, mean age 62 ± 11 years) with low-to...
Gespeichert in:
| Hauptverfasser: | , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2017
|
| In: |
The American journal of cardiology
Year: 2017, Jahrgang: 119, Heft: 8, Pages: 1156-1161 |
| ISSN: | 1879-1913 |
| DOI: | 10.1016/j.amjcard.2016.12.028 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1016/j.amjcard.2016.12.028 |
| Verfasserangaben: | Georg Apfaltrer, Dieter H. Szolar, Eric Wurzinger, Richard A. P. Takx, John W. Nance, Anja Dutschke, Sebastian Tschauner, Christian Loewe, Helmut Ringl, Erich Sorantin, and Paul Apfaltrer |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1577003039 | ||
| 003 | DE-627 | ||
| 005 | 20240316100447.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180628s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.amjcard.2016.12.028 |2 doi | |
| 035 | |a (DE-627)1577003039 | ||
| 035 | |a (DE-576)507003039 | ||
| 035 | |a (DE-599)BSZ507003039 | ||
| 035 | |a (OCoLC)1341012976 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Apfaltrer, Georg |e VerfasserIn |0 (DE-588)116187884X |0 (DE-627)1025398904 |0 (DE-576)507003993 |4 aut | |
| 245 | 1 | 0 | |a Impact on image quality and radiation dose of third-generation dual-source computed tomography of the coronary arteries |c Georg Apfaltrer, Dieter H. Szolar, Eric Wurzinger, Richard A. P. Takx, John W. Nance, Anja Dutschke, Sebastian Tschauner, Christian Loewe, Helmut Ringl, Erich Sorantin, and Paul Apfaltrer |
| 264 | 1 | |c 2017 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 25 January 2017 | ||
| 500 | |a Gesehen am 28.06.2018 | ||
| 520 | |a The aim of this study was to assess the image quality (IQ) and radiation dose of third-generation dual-source computed tomography (CT) coronary angiography (cCTA) in comparison with 64-slice single-source CT. This retrospective study included 140 patients (73 men, mean age 62 ± 11 years) with low-to-intermediate probability of coronary artery disease who underwent either third-generation dual-source cCTA using prospectively electrocardiography-triggered high-pitch spiral acquisition (n = 70) (group 1) or retrospective electrocardiography-gated cCTA on a 64-slice CT system (n = 70) (group 2). Contrast-to-noise and signal-to-noise ratios were measured within the aorta and coronary arteries. Subjective IQ was assessed using a 5-point Likert scale. Effective dose was estimated using specific conversion factors. The contrast-to-noise ratio of group 1 was significantly higher than group 2 at all levels (all p <0.001). Signal-to-noise ratio of group 1 was also significantly higher than group 2 (p <0.05), except for the distal left circumflex artery. Subjective IQ for group 1 was rated significantly better than for group 2 (median score [25th to 75th percentile]: 1 [1 to 2] vs 2 [2 to 3]; p <0.001). The median effective dose was 1.55 mSv (1.09 to 1.88) in group 1 versus 12.29 mSv (11.63 to 14.36) in group 2 (p <0.001) which corresponds to a mean radiation dose reduction of 87.4%. In conclusion, implementation of third-generation dual-source CT system for cCTA leads to improved IQ with significant radiation dose savings. | ||
| 650 | 4 | |a Adult | |
| 650 | 4 | |a Aged | |
| 650 | 4 | |a Aged, 80 and over | |
| 650 | 4 | |a Cardiac-Gated Imaging Techniques | |
| 650 | 4 | |a Coronary Angiography | |
| 650 | 4 | |a Coronary Artery Disease | |
| 650 | 4 | |a Electrocardiography | |
| 650 | 4 | |a Female | |
| 650 | 4 | |a Humans | |
| 650 | 4 | |a Image Processing, Computer-Assisted | |
| 650 | 4 | |a Male | |
| 650 | 4 | |a Middle Aged | |
| 650 | 4 | |a Radiation Dosage | |
| 650 | 4 | |a Retrospective Studies | |
| 650 | 4 | |a Tomography, X-Ray Computed | |
| 700 | 1 | |a Dutschke, Anja |d 1988- |e VerfasserIn |0 (DE-588)1082552879 |0 (DE-627)847636356 |0 (DE-576)455506140 |4 aut | |
| 700 | 1 | |a Apfaltrer, Paul |d 1983- |e VerfasserIn |0 (DE-588)1025309898 |0 (DE-627)722024924 |0 (DE-576)370191757 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t The American journal of cardiology |d Amsterdam [u.a.] : Elsevier, 1958 |g 119(2017), 8, Seite 1156-1161 |h Online-Ressource |w (DE-627)320596249 |w (DE-600)2019595-3 |w (DE-576)10963392X |x 1879-1913 |7 nnas |a Impact on image quality and radiation dose of third-generation dual-source computed tomography of the coronary arteries |
| 773 | 1 | 8 | |g volume:119 |g year:2017 |g number:8 |g pages:1156-1161 |g extent:6 |a Impact on image quality and radiation dose of third-generation dual-source computed tomography of the coronary arteries |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.amjcard.2016.12.028 |x Verlag |x Resolving-System |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180628 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 1025309898 |a Apfaltrer, Paul |m 1025309898:Apfaltrer, Paul |d 60000 |d 62900 |e 60000PA1025309898 |e 62900PA1025309898 |k 0/60000/ |k 1/60000/62900/ |p 11 |y j | ||
| 998 | |g 1082552879 |a Dutschke, Anja |m 1082552879:Dutschke, Anja |d 910000 |d 911400 |e 910000PD1082552879 |e 911400PD1082552879 |k 0/910000/ |k 1/910000/911400/ |p 6 | ||
| 999 | |a KXP-PPN1577003039 |e 3014698512 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"eki":["1577003039"],"doi":["10.1016/j.amjcard.2016.12.028"]},"origin":[{"dateIssuedDisp":"2017","dateIssuedKey":"2017"}],"name":{"displayForm":["Georg Apfaltrer, Dieter H. Szolar, Eric Wurzinger, Richard A. P. Takx, John W. Nance, Anja Dutschke, Sebastian Tschauner, Christian Loewe, Helmut Ringl, Erich Sorantin, and Paul Apfaltrer"]},"relHost":[{"title":[{"title":"The American journal of cardiology","subtitle":"official journal of the American College of Cardiology","title_sort":"American journal of cardiology"}],"disp":"Impact on image quality and radiation dose of third-generation dual-source computed tomography of the coronary arteriesThe American journal of cardiology","note":["Gesehen am 22.12.10","Ungezählte Beil.: Supplement"],"type":{"media":"Online-Ressource","bibl":"periodical"},"corporate":[{"role":"isb","roleDisplay":"Herausgebendes Organ","display":"American College of Cardiology"}],"language":["eng"],"recId":"320596249","pubHistory":["1.1958 -"],"part":{"volume":"119","text":"119(2017), 8, Seite 1156-1161","extent":"6","year":"2017","pages":"1156-1161","issue":"8"},"name":{"displayForm":["ed.-in-chief Simon Dack"]},"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1958-","dateIssuedKey":"1958","publisher":"Elsevier"}],"id":{"eki":["320596249"],"zdb":["2019595-3"],"issn":["1879-1913"]},"physDesc":[{"extent":"Online-Ressource"}]}],"physDesc":[{"extent":"6 S."}],"title":[{"title":"Impact on image quality and radiation dose of third-generation dual-source computed tomography of the coronary arteries","title_sort":"Impact on image quality and radiation dose of third-generation dual-source computed tomography of the coronary arteries"}],"person":[{"given":"Georg","family":"Apfaltrer","role":"aut","display":"Apfaltrer, Georg","roleDisplay":"VerfasserIn"},{"role":"aut","display":"Dutschke, Anja","roleDisplay":"VerfasserIn","given":"Anja","family":"Dutschke"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Apfaltrer, Paul","given":"Paul","family":"Apfaltrer"}],"recId":"1577003039","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Available online 25 January 2017","Gesehen am 28.06.2018"]} | ||
| SRT | |a APFALTRERGIMPACTONIM2017 | ||