Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements

Purpose: To evaluate the repeatability and comparability of biometry parameters between a Scheimpflug-based topography with axial length measurement (Pentacam AXL, Oculus, Wetzlar, Germany) and a swept-source optical biometry (IOLMaster 700, Carl Zeiss Meditec AG, Jena, Germany). Methods: A total of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sel, Saadettin (VerfasserIn) , Kaiser, Delia (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 23 March 2017
In: Contact lens and anterior eye
Year: 2017, Jahrgang: 40, Heft: 5, Pages: 318-322
ISSN:1476-5411
DOI:10.1016/j.clae.2017.03.007
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.clae.2017.03.007
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1367048416302296
Volltext
Verfasserangaben:Saadettin Sel, Jana Stange, Delia Kaiser, Laszlo Kiraly

MARC

LEADER 00000caa a2200000 c 4500
001 1577261836
003 DE-627
005 20220814183332.0
007 cr uuu---uuuuu
008 180704s2017 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.clae.2017.03.007  |2 doi 
035 |a (DE-627)1577261836 
035 |a (DE-576)507261836 
035 |a (DE-599)BSZ507261836 
035 |a (OCoLC)1341013341 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Sel, Saadettin  |d 1968-  |e VerfasserIn  |0 (DE-588)122466926  |0 (DE-627)081961472  |0 (DE-576)293284474  |4 aut 
245 1 0 |a Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements  |c Saadettin Sel, Jana Stange, Delia Kaiser, Laszlo Kiraly 
264 1 |c 23 March 2017 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 23 March 2017 
500 |a Gesehen am 04.07.2018 
520 |a Purpose: To evaluate the repeatability and comparability of biometry parameters between a Scheimpflug-based topography with axial length measurement (Pentacam AXL, Oculus, Wetzlar, Germany) and a swept-source optical biometry (IOLMaster 700, Carl Zeiss Meditec AG, Jena, Germany). Methods: A total of 50 eyes from 50 adult subjects had biometry measurements in one session three times using the Pentacam AXL and the IOLMaster 700. Keratometry, anterior chamber depth (ACD) and axial length (AL) values were obtained by both devices. Mean keratometry (Kmean) was calculated and the corneal spherocylinder was converted into power vectors (J0, J45). Repeatability was assessed based on intraclass correlation coefficient (ICC). Agreement was evaluated by linear regression analysis and Bland-Altman analysis by calculating the mean difference and 95% limits of agreement (LoA). Results: Assessment of intraoperator repeatability by means of ICC showed excellent reproducibility of measurements for both devices and all parameters examined ranging from 0.994 to 1.0. IOLMaster 700 exhibited significantly higher Kmean (p<0.001) and AL (p<0.001) values than the Pentacam AXL. Pentacam AXL showed significantly higher ACD (p<0.001) measurements than IOLMaster 700. There was no statistically significant difference of J0 (p=0.115) and J45 (p=0.255) values between Pentacam AXL and IOLMaster 700. Conclusions: Both devices provide high reproducible values for all parameters investigated. J0 and J45 values are statistically and clinically interchangeable between Pentacam AXL and IOLMaster 700. All other parameters are statistically different. In clinical practice, the differences for ACD and AL are to small and the values can be used interchangeable. However, Kmean values are clinically and statistically different and cannot be used interchangeable between the two devices. 
650 4 |a Anterior chamber depth 
650 4 |a Astigmatism 
650 4 |a Axial length 
650 4 |a Cornea 
650 4 |a IOLMaster 700 
650 4 |a Pentacam AXL 
700 1 |a Kaiser, Delia  |e VerfasserIn  |0 (DE-588)1160217289  |0 (DE-627)1023352249  |0 (DE-576)505567679  |4 aut 
773 0 8 |i Enthalten in  |t Contact lens and anterior eye  |d Basingstoke : Stockton Press, 1997  |g 40(2017), 5, Seite 318-322  |h Online-Ressource  |w (DE-627)320440311  |w (DE-600)2004847-6  |w (DE-576)267761805  |x 1476-5411  |7 nnas  |a Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements 
773 1 8 |g volume:40  |g year:2017  |g number:5  |g pages:318-322  |g extent:5  |a Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements 
856 4 0 |u http://dx.doi.org/10.1016/j.clae.2017.03.007  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1367048416302296  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180704 
993 |a Article 
994 |a 2017 
998 |g 1160217289  |a Kaiser, Delia  |m 1160217289:Kaiser, Delia  |d 910000  |d 910900  |e 910000PK1160217289  |e 910900PK1160217289  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 122466926  |a Sel, Saadettin  |m 122466926:Sel, Saadettin  |d 910000  |d 910900  |e 910000PS122466926  |e 910900PS122466926  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1577261836  |e 3016083175 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Available online 23 March 2017","Gesehen am 04.07.2018"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1577261836","language":["eng"],"title":[{"title":"Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements","title_sort":"Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements"}],"person":[{"display":"Sel, Saadettin","roleDisplay":"VerfasserIn","role":"aut","family":"Sel","given":"Saadettin"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Kaiser, Delia","given":"Delia","family":"Kaiser"}],"physDesc":[{"extent":"5 S."}],"relHost":[{"origin":[{"dateIssuedDisp":"1997-","dateIssuedKey":"1997","publisher":"Stockton Press","publisherPlace":"Basingstoke"}],"id":{"issn":["1476-5411"],"zdb":["2004847-6"],"eki":["320440311"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Contact lens and anterior eye","title":"Contact lens and anterior eye","subtitle":"the journal of the British Contact Lens Association"}],"note":["Gesehen am 10.02.2021"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurementsContact lens and anterior eye","recId":"320440311","corporate":[{"role":"isb","roleDisplay":"Herausgebendes Organ","display":"British Contact Lens Association"}],"language":["eng"],"pubHistory":["20.1997 -"],"part":{"volume":"40","text":"40(2017), 5, Seite 318-322","extent":"5","year":"2017","pages":"318-322","issue":"5"}}],"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"23 March 2017"}],"id":{"eki":["1577261836"],"doi":["10.1016/j.clae.2017.03.007"]},"name":{"displayForm":["Saadettin Sel, Jana Stange, Delia Kaiser, Laszlo Kiraly"]}} 
SRT |a SELSAADETTREPEATABIL2320