Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens

Journal of Refractive Surgery | PURPOSE:To assess the influence of decentration and aperture size on the optical quality of different intraocular lenses (IOLs) of the same material, body design, and refractive power using standardized optical bench testing.METHODS:Using an optical bench set-up, an a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Tandogan, Tamer (VerfasserIn) , Son, Hyeck Soo (VerfasserIn) , Choi, Chul Y. (VerfasserIn) , Knorz, Michael C. (VerfasserIn) , Auffarth, Gerd U. (VerfasserIn) , Khoramnia, Ramin (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: December 12, 2017
In: Journal of refractive surgery
Year: 2017, Jahrgang: 33, Heft: 12, Pages: 808-812
ISSN:1938-2391
DOI:10.3928/1081597X-20171004-02
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.3928/1081597X-20171004-02
Verlag, Volltext: https://www.healio.com/ophthalmology/journals/jrs/2017-12-33-12/%7Bdab8a44d-735a-4b85-bda1-3de24451358e%7D/laboratory-evaluation-of-the-influence-of-decentration-and-pupil-size-on-the-optical-performance-of-a-monofocal-bifocal-and-trifocal-intraocular-lens
Volltext
Verfasserangaben:Tamer Tandogan, MD, Hyeck Soo Son, MD, PhD, Chul Young Choi, Michael C. Knorz, MD, PhD, Gerd U. Auffarth, MD, PhD, Ramin Khoramnia, MD

MARC

LEADER 00000caa a22000002c 4500
001 1577428080
003 DE-627
005 20220814185840.0
007 cr uuu---uuuuu
008 180709s2017 xx |||||o 00| ||eng c
024 7 |a 10.3928/1081597X-20171004-02  |2 doi 
035 |a (DE-627)1577428080 
035 |a (DE-576)507428080 
035 |a (DE-599)BSZ507428080 
035 |a (OCoLC)1341013614 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Tandogan, Tamer  |d 1965-  |e VerfasserIn  |0 (DE-588)129861812  |0 (DE-627)48236419X  |0 (DE-576)297874578  |4 aut 
245 1 0 |a Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens  |c Tamer Tandogan, MD, Hyeck Soo Son, MD, PhD, Chul Young Choi, Michael C. Knorz, MD, PhD, Gerd U. Auffarth, MD, PhD, Ramin Khoramnia, MD 
264 1 |c December 12, 2017 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.07.2018 
520 |a Journal of Refractive Surgery | PURPOSE:To assess the influence of decentration and aperture size on the optical quality of different intraocular lenses (IOLs) of the same material, body design, and refractive power using standardized optical bench testing.METHODS:Using an optical bench set-up, an aspheric monofocal (CT ASPHINA 409M; Carl Zeiss Meditec, Jena, Germany), an aspheric diffractive bifocal (AT LISA 809M; Carl Zeiss 
700 1 |a Son, Hyeck Soo  |d 1991-  |e VerfasserIn  |0 (DE-588)1136747931  |0 (DE-627)893534676  |0 (DE-576)49081686X  |4 aut 
700 1 |a Choi, Chul Y.  |e VerfasserIn  |0 (DE-588)1127253972  |0 (DE-627)881702617  |0 (DE-576)485152460  |4 aut 
700 1 |a Knorz, Michael C.  |e VerfasserIn  |0 (DE-588)112841988  |0 (DE-627)502583126  |0 (DE-576)289744253  |4 aut 
700 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
700 1 |a Khoramnia, Ramin  |d 1980-  |e VerfasserIn  |0 (DE-588)132573954  |0 (DE-627)523957173  |0 (DE-576)299234355  |4 aut 
773 0 8 |i Enthalten in  |t Journal of refractive surgery  |d Thorofare, NJ : SLACK Inc., 1996  |g 33(2017), 12, Seite 808-812  |h Online-Ressource  |w (DE-627)333811267  |w (DE-600)2056758-3  |w (DE-576)433787627  |x 1938-2391  |7 nnas  |a Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens 
773 1 8 |g volume:33  |g year:2017  |g number:12  |g pages:808-812  |g extent:5  |a Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens 
856 4 0 |u http://dx.doi.org/10.3928/1081597X-20171004-02  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://www.healio.com/ophthalmology/journals/jrs/2017-12-33-12/%7Bdab8a44d-735a-4b85-bda1-3de24451358e%7D/laboratory-evaluation-of-the-influence-of-decentration-and-pupil-size-on-the-optical-performance-of-a-monofocal-bifocal-and-trifocal-intraocular-lens  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180709 
993 |a Article 
994 |a 2017 
998 |g 132573954  |a Khoramnia, Ramin  |m 132573954:Khoramnia, Ramin  |d 910000  |d 910900  |e 910000PK132573954  |e 910900PK132573954  |k 0/910000/  |k 1/910000/910900/  |p 6  |y j 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 5 
998 |g 112841988  |a Knorz, Michael C.  |m 112841988:Knorz, Michael C.  |d 60000  |d 61700  |e 60000PK112841988  |e 61700PK112841988  |k 0/60000/  |k 1/60000/61700/  |p 4 
998 |g 1127253972  |a Choi, Chul Y.  |m 1127253972:Choi, Chul Y.  |d 910000  |d 910900  |e 910000PC1127253972  |e 910900PC1127253972  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 1136747931  |a Son, Hyeck Soo  |m 1136747931:Son, Hyeck Soo  |d 910000  |d 910900  |e 910000PS1136747931  |e 910900PS1136747931  |k 0/910000/  |k 1/910000/910900/  |p 2 
998 |g 129861812  |a Tandogan, Tamer  |m 129861812:Tandogan, Tamer  |d 910000  |d 910900  |e 910000PT129861812  |e 910900PT129861812  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1577428080  |e 3016697025 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1577428080","physDesc":[{"extent":"5 S."}],"relHost":[{"recId":"333811267","physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 26.09.24"],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["Nachgewiesen 12.1996 -"],"language":["eng"],"origin":[{"dateIssuedDisp":"1996-","publisher":"SLACK Inc.","publisherPlace":"Thorofare, NJ","dateIssuedKey":"1996"}],"id":{"zdb":["2056758-3"],"issn":["1938-2391"],"eki":["333811267"]},"part":{"pages":"808-812","text":"33(2017), 12, Seite 808-812","year":"2017","volume":"33","extent":"5","issue":"12"},"title":[{"subtitle":"the official publication of the International Society of Refractive Surgery","title_sort":"Journal of refractive surgery","title":"Journal of refractive surgery"}],"disp":"Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lensJournal of refractive surgery"}],"language":["eng"],"note":["Gesehen am 09.07.2018"],"id":{"doi":["10.3928/1081597X-20171004-02"],"eki":["1577428080"]},"person":[{"role":"aut","display":"Tandogan, Tamer","family":"Tandogan","given":"Tamer"},{"given":"Hyeck Soo","family":"Son","role":"aut","display":"Son, Hyeck Soo"},{"given":"Chul Y.","display":"Choi, Chul Y.","role":"aut","family":"Choi"},{"display":"Knorz, Michael C.","role":"aut","family":"Knorz","given":"Michael C."},{"given":"Gerd U.","role":"aut","display":"Auffarth, Gerd U.","family":"Auffarth"},{"given":"Ramin","role":"aut","display":"Khoramnia, Ramin","family":"Khoramnia"}],"origin":[{"dateIssuedDisp":"December 12, 2017","dateIssuedKey":"2017"}],"title":[{"title_sort":"Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens","title":"Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens"}],"name":{"displayForm":["Tamer Tandogan, MD, Hyeck Soo Son, MD, PhD, Chul Young Choi, Michael C. Knorz, MD, PhD, Gerd U. Auffarth, MD, PhD, Ramin Khoramnia, MD"]},"type":{"media":"Online-Ressource","bibl":"article-journal"}} 
SRT |a TANDOGANTALABORATORY1220