Time-resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification

Purpose: Our group previously introduced an in vivo proton range verification methodology in which a silicon diode array system is used to correlate the dose rate profile per range modulation wheel cycle of the detector signal to the water-equivalent path length (WEPL) for passively scattered proton...

Full description

Saved in:
Bibliographic Details
Main Authors: Toltz, Allison (Author) , Hösl, Michaela (Author)
Format: Article (Journal)
Language:English
Published: 29 October 2017
In: Journal of applied clinical medical physics
Year: 2017, Volume: 18, Issue: 6, Pages: 200-205
ISSN:1526-9914
DOI:10.1002/acm2.12210
Online Access:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1002/acm2.12210
Verlag, kostenfrei, Volltext: https://aapm.onlinelibrary.wiley.com/doi/abs/10.1002/acm2.12210
Get full text
Author Notes:Allison Toltz, Michaela Hoesl, Jan Schuemann, Jan Seuntjens, Hsiao-Ming Lu, Harald Paganetti

MARC

LEADER 00000caa a2200000 c 4500
001 1577520033
003 DE-627
005 20230426230634.0
007 cr uuu---uuuuu
008 180711s2017 xx |||||o 00| ||eng c
024 7 |a 10.1002/acm2.12210  |2 doi 
035 |a (DE-627)1577520033 
035 |a (DE-576)507520033 
035 |a (DE-599)BSZ507520033 
035 |a (OCoLC)1341013532 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Toltz, Allison  |e VerfasserIn  |0 (DE-588)1162594470  |0 (DE-627)1026715830  |0 (DE-576)507521137  |4 aut 
245 1 0 |a Time-resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification  |c Allison Toltz, Michaela Hoesl, Jan Schuemann, Jan Seuntjens, Hsiao-Ming Lu, Harald Paganetti 
264 1 |c 29 October 2017 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 11.07.2018 
520 |a Purpose: Our group previously introduced an in vivo proton range verification methodology in which a silicon diode array system is used to correlate the dose rate profile per range modulation wheel cycle of the detector signal to the water-equivalent path length (WEPL) for passively scattered proton beam delivery. The implementation of this system requires a set of calibration data to establish a beam-specific response to WEPL fit for the selected ‘scout’ beam (a 1 cm overshoot of the predicted detector depth with a dose of 4 cGy) in water-equivalent plastic. This necessitates a separate set of measurements for every ‘scout’ beam that may be appropriate to the clinical case. The current study demonstrates the use of Monte Carlo simulations for calibration of the time-resolved diode dosimetry technique. Methods: Measurements for three ‘scout’ beams were compared against simulated detector response with Monte Carlo methods using the Tool for Particle Simulation (TOPAS). The ‘scout’ beams were then applied in the simulation environment to simulated water-equivalent plastic, a CT of water-equivalent plastic, and a patient CT data set to assess uncertainty. Results: Simulated detector response in water-equivalent plastic was validated against measurements for ‘scout’ spread out Bragg peaks of range 10 cm, 15 cm, and 21 cm (168 MeV, 177 MeV, and 210 MeV) to within 3.4 mm for all beams, and to within 1 mm in the region where the detector is expected to lie. Conclusion: Feasibility has been shown for performing the calibration of the detector response for three ‘scout’ beams through simulation for the time-resolved diode dosimetry technique in passive scattered proton delivery. 
650 4 |a proton therapy 
650 4 |a radiation dosimetry 
650 4 |a TOPAS 
700 1 |a Hösl, Michaela  |d 1989-  |e VerfasserIn  |0 (DE-588)1171734050  |0 (DE-627)1040676995  |0 (DE-576)513822445  |4 aut 
773 0 8 |i Enthalten in  |t Journal of applied clinical medical physics  |d Reston, Va. : ACMP, 2000  |g 18(2017), 6, Seite 200-205  |h Online-Ressource  |w (DE-627)312202091  |w (DE-600)2010347-5  |w (DE-576)281192669  |x 1526-9914  |7 nnas  |a Time-resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification 
773 1 8 |g volume:18  |g year:2017  |g number:6  |g pages:200-205  |g extent:6  |a Time-resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification 
856 4 0 |u http://dx.doi.org/10.1002/acm2.12210  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://aapm.onlinelibrary.wiley.com/doi/abs/10.1002/acm2.12210  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20180711 
993 |a Article 
994 |a 2017 
998 |g 1171734050  |a Hösl, Michaela  |m 1171734050:Hösl, Michaela  |p 2 
999 |a KXP-PPN1577520033  |e 3017335992 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 11.07.2018"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1577520033","language":["eng"],"title":[{"title":"Time-resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification","title_sort":"Time-resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification"}],"person":[{"given":"Allison","family":"Toltz","role":"aut","roleDisplay":"VerfasserIn","display":"Toltz, Allison"},{"role":"aut","display":"Hösl, Michaela","roleDisplay":"VerfasserIn","given":"Michaela","family":"Hösl"}],"physDesc":[{"extent":"6 S."}],"relHost":[{"name":{"displayForm":["American College of Medical Physics"]},"origin":[{"publisherPlace":"Reston, Va.","dateIssuedKey":"2000","publisher":"ACMP","dateIssuedDisp":"2000-"}],"id":{"issn":["1526-9914"],"zdb":["2010347-5"],"eki":["312202091"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Journal of applied clinical medical physics","title_sort":"Journal of applied clinical medical physics"}],"disp":"Time-resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verificationJournal of applied clinical medical physics","note":["Gesehen am 17. Januar 2017"],"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"312202091","language":["eng"],"pubHistory":["1.2000 -"],"part":{"volume":"18","text":"18(2017), 6, Seite 200-205","extent":"6","year":"2017","pages":"200-205","issue":"6"}}],"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"29 October 2017"}],"id":{"doi":["10.1002/acm2.12210"],"eki":["1577520033"]},"name":{"displayForm":["Allison Toltz, Michaela Hoesl, Jan Schuemann, Jan Seuntjens, Hsiao-Ming Lu, Harald Paganetti"]}} 
SRT |a TOLTZALLISTIMERESOLV2920