Quantitative pupil analysis in stimulated emission depletion microscopy using phase retrieval
The resolution attainable with stimulated emission depletion (STED) microscopy greatly depends on the quality of the STED laser focus. So far, visual inspection of a measured STED focus has been the only convenient means of gauging the source of aberrations. Here we describe a method, requiring no i...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
May 17, 2012
|
| In: |
Optics letters
Year: 2012, Volume: 37, Issue: 11, Pages: 1805-1807 |
| ISSN: | 1539-4794 |
| DOI: | 10.1364/OL.37.001805 |
| Online Access: | Verlag, Volltext: http://dx.doi.org/10.1364/OL.37.001805 Verlag, Volltext: https://www.osapublishing.org/ol/abstract.cfm?uri=ol-37-11-1805 |
| Author Notes: | Emil B. Kromann, Travis J. Gould, Manuel F. Juette, Jens E. Wilhjelm, and Joerg Bewersdorf |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1577545761 | ||
| 003 | DE-627 | ||
| 005 | 20230426230638.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180712s2012 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1364/OL.37.001805 |2 doi | |
| 035 | |a (DE-627)1577545761 | ||
| 035 | |a (DE-576)507545761 | ||
| 035 | |a (DE-599)BSZ507545761 | ||
| 035 | |a (OCoLC)1341013606 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Kromann, Emil |e VerfasserIn |0 (DE-588)1162854545 |0 (DE-627)1026944961 |0 (DE-576)507620992 |4 aut | |
| 245 | 1 | 0 | |a Quantitative pupil analysis in stimulated emission depletion microscopy using phase retrieval |c Emil B. Kromann, Travis J. Gould, Manuel F. Juette, Jens E. Wilhjelm, and Joerg Bewersdorf |
| 264 | 1 | |c May 17, 2012 | |
| 300 | |a 3 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 12.07.2018 | ||
| 520 | |a The resolution attainable with stimulated emission depletion (STED) microscopy greatly depends on the quality of the STED laser focus. So far, visual inspection of a measured STED focus has been the only convenient means of gauging the source of aberrations. Here we describe a method, requiring no instrument modifications, for obtaining an equivalent to the complex pupil function at the back aperture of the objective and show that it provides quantitative information about aberration sources (including aberrations induced by the objective or sample). We show the accuracy of this field representation to be sufficient for reconstructing the STED focus in three dimensions and determining corrective steps. | ||
| 650 | 4 | |a Circular polarization | |
| 650 | 4 | |a Destructive interference | |
| 650 | 4 | |a Diffraction limit | |
| 650 | 4 | |a Image resolution | |
| 650 | 4 | |a Laser beams | |
| 650 | 4 | |a Phase retrieval | |
| 700 | 1 | |a Juette, Manuel Friedrich |e VerfasserIn |0 (DE-588)1030540179 |0 (DE-627)735460310 |0 (DE-576)378392131 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Optics letters |d Washington, DC : Soc., 1977 |g 37(2012), 11, Seite 1805-1807 |h Online-Ressource |w (DE-627)271176083 |w (DE-600)1479014-2 |w (DE-576)078412366 |x 1539-4794 |7 nnas |a Quantitative pupil analysis in stimulated emission depletion microscopy using phase retrieval |
| 773 | 1 | 8 | |g volume:37 |g year:2012 |g number:11 |g pages:1805-1807 |g extent:3 |a Quantitative pupil analysis in stimulated emission depletion microscopy using phase retrieval |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1364/OL.37.001805 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://www.osapublishing.org/ol/abstract.cfm?uri=ol-37-11-1805 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180712 | ||
| 993 | |a Article | ||
| 994 | |a 2012 | ||
| 998 | |g 1030540179 |a Juette, Manuel Friedrich |m 1030540179:Juette, Manuel Friedrich |d 120000 |d 120300 |e 120000PJ1030540179 |e 120300PJ1030540179 |k 0/120000/ |k 1/120000/120300/ |p 3 | ||
| 999 | |a KXP-PPN1577545761 |e 3017468194 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"title":[{"title":"Optics letters","title_sort":"Optics letters"}],"recId":"271176083","language":["eng"],"corporate":[{"display":"Optical Society of America","roleDisplay":"Herausgebendes Organ","role":"isb"}],"note":["Gesehen am 30.04.15"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Quantitative pupil analysis in stimulated emission depletion microscopy using phase retrievalOptics letters","part":{"text":"37(2012), 11, Seite 1805-1807","volume":"37","extent":"3","year":"2012","issue":"11","pages":"1805-1807"},"pubHistory":["1.1977 -"],"id":{"issn":["1539-4794"],"zdb":["1479014-2"],"eki":["271176083"]},"origin":[{"dateIssuedDisp":"1977-","publisher":"Soc.","dateIssuedKey":"1977","publisherPlace":"Washington, DC"}],"physDesc":[{"extent":"Online-Ressource"}]}],"physDesc":[{"extent":"3 S."}],"name":{"displayForm":["Emil B. Kromann, Travis J. Gould, Manuel F. Juette, Jens E. Wilhjelm, and Joerg Bewersdorf"]},"id":{"eki":["1577545761"],"doi":["10.1364/OL.37.001805"]},"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"May 17, 2012"}],"language":["eng"],"recId":"1577545761","note":["Gesehen am 12.07.2018"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"family":"Kromann","given":"Emil","display":"Kromann, Emil","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Manuel Friedrich","family":"Juette","role":"aut","display":"Juette, Manuel Friedrich","roleDisplay":"VerfasserIn"}],"title":[{"title":"Quantitative pupil analysis in stimulated emission depletion microscopy using phase retrieval","title_sort":"Quantitative pupil analysis in stimulated emission depletion microscopy using phase retrieval"}]} | ||
| SRT | |a KROMANNEMIQUANTITATI1720 | ||