Simultaneous multislice imaging for native myocardial T1 mapping: improved spatial coverage in a single breath-hold

Purpose To develop a saturation recovery myocardial T1 mapping method for the simultaneous multislice acquisition of three slices. Methods Saturation pulse-prepared heart rate independent inversion recovery (SAPPHIRE) T1 mapping was implemented with simultaneous multislice imaging using FLASH readou...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Weingärtner, Sebastian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 5 June 2017
In: Magnetic resonance in medicine
Year: 2017, Jahrgang: 78, Heft: 2, Pages: 462-471
ISSN:1522-2594
DOI:10.1002/mrm.26770
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1002/mrm.26770
Verlag, Volltext: https://onlinelibrary-wiley-com.ezproxy.medma.uni-heidelberg.de/doi/abs/10.1002/mrm.26770
Volltext
Verfasserangaben:Sebastian Weingärtner, Steen Moeller, Sebastian Schmitter, Edward Auerbach, Peter Kellman, Chetan Shenoy, and Mehmet Akçakaya

MARC

LEADER 00000caa a2200000 c 4500
001 1577656318
003 DE-627
005 20230426230656.0
007 cr uuu---uuuuu
008 180717s2017 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrm.26770  |2 doi 
035 |a (DE-627)1577656318 
035 |a (DE-576)507656318 
035 |a (DE-599)BSZ507656318 
035 |a (OCoLC)1341013952 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Weingärtner, Sebastian  |d 1991-  |e VerfasserIn  |0 (DE-588)1051891507  |0 (DE-627)786975199  |0 (DE-576)407522883  |4 aut 
245 1 0 |a Simultaneous multislice imaging for native myocardial T1 mapping  |b improved spatial coverage in a single breath-hold  |c Sebastian Weingärtner, Steen Moeller, Sebastian Schmitter, Edward Auerbach, Peter Kellman, Chetan Shenoy, and Mehmet Akçakaya 
264 1 |c 5 June 2017 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 17.07.2018 
500 |a Im Titel ist "1" tiefgestellt 
520 |a Purpose To develop a saturation recovery myocardial T1 mapping method for the simultaneous multislice acquisition of three slices. Methods Saturation pulse-prepared heart rate independent inversion recovery (SAPPHIRE) T1 mapping was implemented with simultaneous multislice imaging using FLASH readouts for faster coverage of the myocardium. Controlled aliasing in parallel imaging (CAIPI) was used to achieve minimal noise amplification in three slices. Multiband reconstruction was performed using three linear reconstruction methods: Slice- and in-plane GRAPPA, CG-SENSE, and Tikhonov-regularized CG-SENSE. Accuracy, spatial variability, and interslice leakage were compared with single-band T1 mapping in a phantom and in six healthy subjects. Results Multiband phantom T1 times showed good agreement with single-band T1 mapping for all three reconstruction methods (normalized root mean square error <1.0%). The increase in spatial variability compared with single-band imaging was lowest for GRAPPA (1.29-fold), with higher penalties for Tikhonov-regularized CG-SENSE (1.47-fold) and CG-SENSE (1.52-fold). In vivo multiband T1 times showed no significant difference compared with single-band (T1 time ± intersegmental variability: single-band, 1580 ± 119 ms; GRAPPA, 1572 ± 145 ms; CG-SENSE, 1579 ± 159 ms; Tikhonov, 1586 ± 150 ms [analysis of variance; P = 0.86]). Interslice leakage was smallest for GRAPPA (5.4%) and higher for CG-SENSE (6.2%) and Tikhonov-regularized CG-SENSE (7.9%). Conclusion Multiband accelerated myocardial T1 mapping demonstrated the potential for single-breath-hold T1 quantification in 16 American Heart Association segments over three slices. A 1.2- to 1.4-fold higher in vivo spatial variability was observed, where GRAPPA-based reconstruction showed the highest homogeneity and the least interslice leakage. 
650 4 |a SAPPHIRE 
650 4 |a multiband 
650 4 |a myocardial T1 mapping 
650 4 |a saturation recovery 
650 4 |a simultaneous multislice imaging 
773 0 8 |i Enthalten in  |t Magnetic resonance in medicine  |d New York, NY [u.a.] : Wiley-Liss, 1984  |g 78(2017), 2, Seite 462-471  |h Online-Ressource  |w (DE-627)303257040  |w (DE-600)1493786-4  |w (DE-576)096290455  |x 1522-2594  |7 nnas  |a Simultaneous multislice imaging for native myocardial T1 mapping improved spatial coverage in a single breath-hold 
773 1 8 |g volume:78  |g year:2017  |g number:2  |g pages:462-471  |g extent:10  |a Simultaneous multislice imaging for native myocardial T1 mapping improved spatial coverage in a single breath-hold 
856 4 0 |u http://dx.doi.org/10.1002/mrm.26770  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary-wiley-com.ezproxy.medma.uni-heidelberg.de/doi/abs/10.1002/mrm.26770  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180717 
993 |a Article 
994 |a 2017 
998 |g 1051891507  |a Weingärtner, Sebastian  |m 1051891507:Weingärtner, Sebastian  |p 1  |x j 
999 |a KXP-PPN1577656318  |e 3018101219 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"10 S."}],"relHost":[{"pubHistory":["1.1984 -"],"titleAlt":[{"title":"MRM"}],"part":{"volume":"78","text":"78(2017), 2, Seite 462-471","extent":"10","year":"2017","issue":"2","pages":"462-471"},"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Simultaneous multislice imaging for native myocardial T1 mapping improved spatial coverage in a single breath-holdMagnetic resonance in medicine","note":["Gesehen am 28.02.08"],"language":["eng"],"recId":"303257040","title":[{"subtitle":"MRM ; an official journal of the International Society for Magnetic Resonance in Medicine","title":"Magnetic resonance in medicine","title_sort":"Magnetic resonance in medicine"}],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"New York, NY [u.a.]","publisher":"Wiley-Liss","dateIssuedKey":"1984","dateIssuedDisp":"1984-"}],"id":{"zdb":["1493786-4"],"eki":["303257040"],"doi":["10.1002/(ISSN)1522-2594"],"issn":["1522-2594"]}}],"origin":[{"dateIssuedDisp":"5 June 2017","dateIssuedKey":"2017"}],"id":{"eki":["1577656318"],"doi":["10.1002/mrm.26770"]},"name":{"displayForm":["Sebastian Weingärtner, Steen Moeller, Sebastian Schmitter, Edward Auerbach, Peter Kellman, Chetan Shenoy, and Mehmet Akçakaya"]},"note":["Gesehen am 17.07.2018","Im Titel ist \"1\" tiefgestellt"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1577656318","language":["eng"],"title":[{"subtitle":"improved spatial coverage in a single breath-hold","title":"Simultaneous multislice imaging for native myocardial T1 mapping","title_sort":"Simultaneous multislice imaging for native myocardial T1 mapping"}],"person":[{"roleDisplay":"VerfasserIn","display":"Weingärtner, Sebastian","role":"aut","family":"Weingärtner","given":"Sebastian"}]} 
SRT |a WEINGAERTNSIMULTANEO5201