Impact of iso- and low-osmolar iodinated contrast agents on BOLD and diffusion MRI in swine kidneys

Purpose: To assess whether functional MR imaging using blood-oxygenation level-dependent (BOLD) imaging and diffusion-weighted imaging demonstrate changes in renal oxygenation and apparent diffusion coefficient (ADC) in a pig model. Materials and Methods: After administration of either 1-g iodine/kg...

Full description

Saved in:
Bibliographic Details
Main Authors: Haneder, Stefan (Author) , Augustin, Jill (Author) , Krämer, Bernhard (Author) , Schönberg, Stefan (Author) , Meyer, Mathias (Author) , Attenberger, Ulrike (Author) , Michaely, Henrik J. M. (Author)
Format: Article (Journal)
Language:English
Published: 2012
In: Investigative radiology
Year: 2012, Volume: 47, Issue: 5, Pages: 299-305
ISSN:1536-0210
DOI:10.1097/RLI.0b013e318240a8ac
Online Access:Verlag, Volltext: http://dx.doi.org/10.1097/RLI.0b013e318240a8ac
Verlag, Volltext: https://journals.lww.com/investigativeradiology/Fulltext/2012/05000/Impact_of_Iso__and_Low_Osmolar_Iodinated_Contrast.5.aspx
Get full text
Author Notes:Stefan Haneder, MD, Jill Augustin, MD, Gregor Jost, PhD, Hubertus Pietsch, PhD, Philipp Lengsfeld, PhD, Bernhard K. Krämer, MD, Stefan O. Schoenberg, MD, Mathias Meyer, Cand. Med, Ulrike I. Attenberger, MD, and Henrik Jakob Michaely, MD

MARC

LEADER 00000caa a2200000 c 4500
001 1577853539
003 DE-627
005 20240316100457.0
007 cr uuu---uuuuu
008 180723s2012 xx |||||o 00| ||eng c
024 7 |a 10.1097/RLI.0b013e318240a8ac  |2 doi 
035 |a (DE-627)1577853539 
035 |a (DE-576)507853539 
035 |a (DE-599)BSZ507853539 
035 |a (OCoLC)1341014219 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 32  |2 sdnb 
100 1 |a Haneder, Stefan  |d 1981-  |e VerfasserIn  |0 (DE-588)136678335  |0 (DE-627)585462097  |0 (DE-576)287960943  |4 aut 
245 1 0 |a Impact of iso- and low-osmolar iodinated contrast agents on BOLD and diffusion MRI in swine kidneys  |c Stefan Haneder, MD, Jill Augustin, MD, Gregor Jost, PhD, Hubertus Pietsch, PhD, Philipp Lengsfeld, PhD, Bernhard K. Krämer, MD, Stefan O. Schoenberg, MD, Mathias Meyer, Cand. Med, Ulrike I. Attenberger, MD, and Henrik Jakob Michaely, MD 
264 1 |c 2012 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 23.07.2018 
520 |a Purpose: To assess whether functional MR imaging using blood-oxygenation level-dependent (BOLD) imaging and diffusion-weighted imaging demonstrate changes in renal oxygenation and apparent diffusion coefficient (ADC) in a pig model. Materials and Methods: After administration of either 1-g iodine/kg body weight low-osmolar iopromide or iso-osmolar iodixanol, 8 mini pigs underwent a series of repeated BOLD measurements (TR/TE 106/5.9-48.7 ms, slice thickness 4 mm) and diffusion-weighted imaging measurements (TR/TE 3900/79 ms, slice thickness 4 mm) for 1 hour at 1.5 T. In this intraindividual cross over study, the second contrast agent injection with the other iodinated contrast agent was performed at least 24 hours after the initial contrast agent injection. BOLD-based R2* values as indirect measures of the renal oxygenation were determined for the cortex, the inner medulla, and the outer medulla. ADC values were measured for the cortex and the whole kidney. Results: For both contrast agents, a drop in R2* was found in the cortex, which normalized after 55 minutes. In the outer medulla and particularly in the inner medulla, a decreased initial drop of R2* was encountered with both contrast agents, with a slow increase toward the baseline R2*. In the inner medulla, elevated R2* values were found with the iso-osmolar contrast agent only. The ADC revealed an initial increase, which slowly decayed over the measurement period. This finding was more pronounced for the cortex compared with the whole-kidney analysis. Conclusion: Functional MR imaging of the kidneys demonstrates increased R2* in the inner medulla only after the administration of the iodixanol potentially indicating hypoxia and thus a pathomechanism of contrast-induced nephropathy. 
700 1 |a Augustin, Jill  |d 1980-  |e VerfasserIn  |0 (DE-588)1024725324  |0 (DE-627)720424283  |0 (DE-576)36940775X  |4 aut 
700 1 |a Krämer, Bernhard  |d 1957-  |e VerfasserIn  |0 (DE-588)14017589X  |0 (DE-627)70358927X  |0 (DE-576)314926852  |4 aut 
700 1 |a Schönberg, Stefan  |d 1969-  |e VerfasserIn  |0 (DE-588)131557912  |0 (DE-627)510700624  |0 (DE-576)298584891  |4 aut 
700 1 |a Meyer, Mathias  |d 1986-  |e VerfasserIn  |0 (DE-588)1025310306  |0 (DE-627)722026021  |0 (DE-576)370193059  |4 aut 
700 1 |a Attenberger, Ulrike  |d 1980-  |e VerfasserIn  |0 (DE-588)131554859  |0 (DE-627)510698557  |0 (DE-576)298582775  |4 aut 
700 1 |a Michaely, Henrik J. M.  |d 1976-  |e VerfasserIn  |0 (DE-588)128817283  |0 (DE-627)381568407  |0 (DE-576)297347624  |4 aut 
773 0 8 |i Enthalten in  |t Investigative radiology  |d Philadelphia, Pa. : Lippincott Williams & Wilkins, 1966  |g 47(2012), 5, Seite 299-305  |h Online-Ressource  |w (DE-627)326645322  |w (DE-600)2041543-6  |w (DE-576)09442568X  |x 1536-0210  |7 nnas  |a Impact of iso- and low-osmolar iodinated contrast agents on BOLD and diffusion MRI in swine kidneys 
773 1 8 |g volume:47  |g year:2012  |g number:5  |g pages:299-305  |g extent:7  |a Impact of iso- and low-osmolar iodinated contrast agents on BOLD and diffusion MRI in swine kidneys 
856 4 0 |u http://dx.doi.org/10.1097/RLI.0b013e318240a8ac  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://journals.lww.com/investigativeradiology/Fulltext/2012/05000/Impact_of_Iso__and_Low_Osmolar_Iodinated_Contrast.5.aspx  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180723 
993 |a Article 
994 |a 2012 
998 |g 128817283  |a Michaely, Henrik J. M.  |m 128817283:Michaely, Henrik J. M.  |d 60000  |d 62900  |e 60000PM128817283  |e 62900PM128817283  |k 0/60000/  |k 1/60000/62900/  |p 10  |y j 
998 |g 131554859  |a Attenberger, Ulrike  |m 131554859:Attenberger, Ulrike  |d 60000  |d 62900  |e 60000PA131554859  |e 62900PA131554859  |k 0/60000/  |k 1/60000/62900/  |p 9 
998 |g 1025310306  |a Meyer, Mathias  |m 1025310306:Meyer, Mathias  |d 60000  |d 62900  |e 60000PM1025310306  |e 62900PM1025310306  |k 0/60000/  |k 1/60000/62900/  |p 8 
998 |g 131557912  |a Schönberg, Stefan  |m 131557912:Schönberg, Stefan  |d 60000  |d 62900  |e 60000PS131557912  |e 62900PS131557912  |k 0/60000/  |k 1/60000/62900/  |p 7 
998 |g 14017589X  |a Krämer, Bernhard  |m 14017589X:Krämer, Bernhard  |d 60000  |d 61400  |e 60000PK14017589X  |e 61400PK14017589X  |k 0/60000/  |k 1/60000/61400/  |p 6 
998 |g 1024725324  |a Augustin, Jill  |m 1024725324:Augustin, Jill  |d 60000  |d 61400  |e 60000PA1024725324  |e 61400PA1024725324  |k 0/60000/  |k 1/60000/61400/  |p 2 
998 |g 136678335  |a Haneder, Stefan  |m 136678335:Haneder, Stefan  |d 60000  |d 62900  |e 60000PH136678335  |e 62900PH136678335  |k 0/60000/  |k 1/60000/62900/  |p 1  |x j 
999 |a KXP-PPN1577853539  |e 3019374979 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2012"}],"note":["Gesehen am 23.07.2018"],"title":[{"title_sort":"Impact of iso- and low-osmolar iodinated contrast agents on BOLD and diffusion MRI in swine kidneys","title":"Impact of iso- and low-osmolar iodinated contrast agents on BOLD and diffusion MRI in swine kidneys"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"role":"aut","given":"Stefan","display":"Haneder, Stefan","family":"Haneder"},{"display":"Augustin, Jill","family":"Augustin","role":"aut","given":"Jill"},{"role":"aut","given":"Bernhard","family":"Krämer","display":"Krämer, Bernhard"},{"given":"Stefan","role":"aut","family":"Schönberg","display":"Schönberg, Stefan"},{"family":"Meyer","display":"Meyer, Mathias","given":"Mathias","role":"aut"},{"role":"aut","given":"Ulrike","display":"Attenberger, Ulrike","family":"Attenberger"},{"family":"Michaely","display":"Michaely, Henrik J. M.","given":"Henrik J. M.","role":"aut"}],"id":{"doi":["10.1097/RLI.0b013e318240a8ac"],"eki":["1577853539"]},"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"recId":"326645322","pubHistory":["1.1966 -"],"id":{"issn":["1536-0210"],"eki":["326645322"],"zdb":["2041543-6"]},"disp":"Impact of iso- and low-osmolar iodinated contrast agents on BOLD and diffusion MRI in swine kidneysInvestigative radiology","part":{"volume":"47","extent":"7","pages":"299-305","text":"47(2012), 5, Seite 299-305","year":"2012","issue":"5"},"title":[{"title":"Investigative radiology","title_sort":"Investigative radiology","subtitle":"a journal of clinical and laboratory research"}],"note":["Gesehen am 01.03.11"],"origin":[{"publisher":"Lippincott Williams & Wilkins ; Ovid","dateIssuedKey":"1966","publisherPlace":"Philadelphia, Pa. ; [Erscheinungsort nicht ermittelbar]","dateIssuedDisp":"1966-"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"]}],"recId":"1577853539","physDesc":[{"extent":"7 S."}],"name":{"displayForm":["Stefan Haneder, MD, Jill Augustin, MD, Gregor Jost, PhD, Hubertus Pietsch, PhD, Philipp Lengsfeld, PhD, Bernhard K. Krämer, MD, Stefan O. Schoenberg, MD, Mathias Meyer, Cand. Med, Ulrike I. Attenberger, MD, and Henrik Jakob Michaely, MD"]}} 
SRT |a HANEDERSTEIMPACTOFIS2012