Design and application of an MR reference phantom for multicentre lung imaging trials

Introduction As there is an increasing number of multicentre lung imaging studies with MRI in patients, dedicated reference phantoms are required to allow for the assessment and comparison of image quality in multi-vendor and multi-centre environments. However, appropriate phantoms for this purpose...

Full description

Saved in:
Bibliographic Details
Main Authors: Triphan, Simon M. F. (Author) , Biederer, Jürgen (Author) , Burmester, Kerstin (Author) , Fellhauer, Iven (Author) , Kauczor, Hans-Ulrich (Author) , Heußel, Claus Peter (Author) , Wielpütz, Mark Oliver (Author) , Jobst, Bertram (Author)
Format: Article (Journal)
Language:English
Published: July 5, 2018
In: PLOS ONE
Year: 2018, Volume: 13, Issue: 7
ISSN:1932-6203
DOI:10.1371/journal.pone.0199148
Online Access:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1371/journal.pone.0199148
Verlag, kostenfrei, Volltext: http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0199148
Get full text
Author Notes:Simon M.F. Triphan, Jürgen Biederer, Kerstin Burmester, Iven Fellhauer, Claus F. Vogelmeier, Rudolf A. Jörres, Hans-Ulrich Kauczor, Claus P. Heußel, Mark O. Wielpütz, Bertram J. Jobst

MARC

LEADER 00000caa a2200000 c 4500
001 1577918983
003 DE-627
005 20210815175911.0
007 cr uuu---uuuuu
008 180725s2018 xx |||||o 00| ||eng c
024 7 |a 10.1371/journal.pone.0199148  |2 doi 
035 |a (DE-627)1577918983 
035 |a (DE-576)507918983 
035 |a (DE-599)BSZ507918983 
035 |a (OCoLC)1264004033 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Triphan, Simon M. F.  |e VerfasserIn  |0 (DE-588)1072565080  |0 (DE-627)827729553  |0 (DE-576)434034207  |4 aut 
245 1 0 |a Design and application of an MR reference phantom for multicentre lung imaging trials  |c Simon M.F. Triphan, Jürgen Biederer, Kerstin Burmester, Iven Fellhauer, Claus F. Vogelmeier, Rudolf A. Jörres, Hans-Ulrich Kauczor, Claus P. Heußel, Mark O. Wielpütz, Bertram J. Jobst 
264 1 |c July 5, 2018 
300 |a 19 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.07.2018 
520 |a Introduction As there is an increasing number of multicentre lung imaging studies with MRI in patients, dedicated reference phantoms are required to allow for the assessment and comparison of image quality in multi-vendor and multi-centre environments. However, appropriate phantoms for this purpose are so far not available commercially. It was therefore the purpose of this project to design and apply a cost-effective and simple to use reference phantom which addresses the specific requirements for imaging the lungs with MRI. Methods The phantom was designed to simulate 4 compartments (lung, blood, muscle and fat) which reflect the specific conditions in proton-MRI of the chest. Multiple phantom instances were produced and measured at 15 sites using a contemporary proton-MRI protocol designed for an in vivo COPD study at intervals over the course of the study. Measures of signal- and contrast-to-noise ratio, as well as structure and edge depiction were extracted from conventionally acquired images using software written for this purpose. Results For the signal to noise ratio, low intra-scanner variability was found with 4.5% in the lung compartment, 4.0% for blood, 3.3% for muscle and 3.7% for fat. The inter-scanner variability was substantially higher, with 41%, 32%, 27% and 32% for the same order of compartments. In addition, measures of structure and edge depiction were found to both vary significantly among several scanner types and among scanners of the same model which were equipped with different gradient systems. Conclusion The described reference phantom reproducibly quantified image quality aspects and detected substantial inter-scanner variability in a typical pulmonary multicentre proton MRI study, while variability was greater in lung tissue compared to other tissue types. Accordingly, appropriate reference phantoms can help to detect bias in multicentre in vivo study results and could also be used to harmonize equipment or data. 
650 4 |a Biomarkers 
650 4 |a Blood 
650 4 |a Computed axial tomography 
650 4 |a Fats 
650 4 |a In vivo imaging 
650 4 |a Magnetic resonance imaging 
650 4 |a Protons 
650 4 |a Pulmonary imaging 
700 1 |a Biederer, Jürgen  |d 1969-  |e VerfasserIn  |0 (DE-588)141247282  |0 (DE-627)625830857  |0 (DE-576)322978122  |4 aut 
700 1 |a Burmester, Kerstin  |e VerfasserIn  |0 (DE-588)1161045570  |0 (DE-627)1024455157  |0 (DE-576)506332276  |4 aut 
700 1 |a Fellhauer, Iven  |e VerfasserIn  |0 (DE-588)1074892860  |0 (DE-627)832653314  |0 (DE-576)443094950  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Heußel, Claus Peter  |e VerfasserIn  |0 (DE-588)1048631389  |0 (DE-627)780769422  |0 (DE-576)40288146X  |4 aut 
700 1 |a Wielpütz, Mark Oliver  |d 1982-  |e VerfasserIn  |0 (DE-588)139999752  |0 (DE-627)614754682  |0 (DE-576)314127046  |4 aut 
700 1 |a Jobst, Bertram  |d 1982-  |e VerfasserIn  |0 (DE-588)1072564750  |0 (DE-627)827728840  |0 (DE-576)434033766  |4 aut 
773 0 8 |i Enthalten in  |t PLOS ONE  |d San Francisco, California, US : PLOS, 2006  |g 13(2018,7) Artikel-Nummer e0199148, 19 Seiten  |h Online-Ressource  |w (DE-627)523574592  |w (DE-600)2267670-3  |w (DE-576)281331979  |x 1932-6203  |7 nnas  |a Design and application of an MR reference phantom for multicentre lung imaging trials 
773 1 8 |g volume:13  |g year:2018  |g number:7  |g extent:19  |a Design and application of an MR reference phantom for multicentre lung imaging trials 
856 4 0 |u http://dx.doi.org/10.1371/journal.pone.0199148  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0199148  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20180725 
993 |a Article 
994 |a 2018 
998 |g 1072564750  |a Jobst, Bertram  |m 1072564750:Jobst, Bertram  |d 910000  |d 911400  |e 910000PJ1072564750  |e 911400PJ1072564750  |k 0/910000/  |k 1/910000/911400/  |p 10  |y j 
998 |g 139999752  |a Wielpütz, Mark Oliver  |m 139999752:Wielpütz, Mark Oliver  |d 910000  |d 911400  |d 50000  |e 910000PW139999752  |e 911400PW139999752  |e 50000PW139999752  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 9 
998 |g 1048631389  |a Heußel, Claus Peter  |m 1048631389:Heußel, Claus Peter  |d 910000  |d 950000  |d 950900  |d 50000  |e 910000PH1048631389  |e 950000PH1048631389  |e 950900PH1048631389  |e 50000PH1048631389  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |k 0/50000/  |p 8 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 1074892860  |a Fellhauer, Iven  |m 1074892860:Fellhauer, Iven  |d 910000  |d 911400  |e 910000PF1074892860  |e 911400PF1074892860  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 1161045570  |a Burmester, Kerstin  |m 1161045570:Burmester, Kerstin  |d 910000  |d 911400  |e 910000PB1161045570  |e 911400PB1161045570  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 141247282  |a Biederer, Jürgen  |m 141247282:Biederer, Jürgen  |d 910000  |d 911400  |e 910000PB141247282  |e 911400PB141247282  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1072565080  |a Triphan, Simon M. F.  |m 1072565080:Triphan, Simon M. F.  |d 910000  |d 911400  |e 910000PT1072565080  |e 911400PT1072565080  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1577918983  |e 3019478774 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1577918983"],"doi":["10.1371/journal.pone.0199148"]},"name":{"displayForm":["Simon M.F. Triphan, Jürgen Biederer, Kerstin Burmester, Iven Fellhauer, Claus F. Vogelmeier, Rudolf A. Jörres, Hans-Ulrich Kauczor, Claus P. Heußel, Mark O. Wielpütz, Bertram J. Jobst"]},"physDesc":[{"extent":"19 S."}],"recId":"1577918983","type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 25.07.2018"],"title":[{"title_sort":"Design and application of an MR reference phantom for multicentre lung imaging trials","title":"Design and application of an MR reference phantom for multicentre lung imaging trials"}],"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"July 5, 2018"}],"relHost":[{"pubHistory":["1.2006 -"],"name":{"displayForm":["Public Library of Science"]},"corporate":[{"display":"Public Library of Science","role":"isb"}],"part":{"issue":"7","volume":"13","text":"13(2018,7) Artikel-Nummer e0199148, 19 Seiten","extent":"19","year":"2018"},"id":{"zdb":["2267670-3"],"eki":["523574592"],"issn":["1932-6203"]},"origin":[{"publisher":"PLOS ; PLoS","publisherPlace":"San Francisco, California, US ; Lawrence, Kan.","dateIssuedKey":"2006","dateIssuedDisp":"2006-"}],"title":[{"title":"PLOS ONE","title_sort":"PLOS ONE"}],"note":["Schreibweise des Titels bis 2012: PLoS ONE","Gesehen am 20.03.19"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"523574592","physDesc":[{"extent":"Online-Ressource"}],"disp":"Design and application of an MR reference phantom for multicentre lung imaging trialsPLOS ONE"}],"person":[{"family":"Triphan","given":"Simon M. F.","role":"aut","display":"Triphan, Simon M. F."},{"given":"Jürgen","role":"aut","family":"Biederer","display":"Biederer, Jürgen"},{"display":"Burmester, Kerstin","family":"Burmester","given":"Kerstin","role":"aut"},{"family":"Fellhauer","role":"aut","given":"Iven","display":"Fellhauer, Iven"},{"given":"Hans-Ulrich","role":"aut","family":"Kauczor","display":"Kauczor, Hans-Ulrich"},{"family":"Heußel","role":"aut","given":"Claus Peter","display":"Heußel, Claus Peter"},{"given":"Mark Oliver","role":"aut","family":"Wielpütz","display":"Wielpütz, Mark Oliver"},{"display":"Jobst, Bertram","role":"aut","given":"Bertram","family":"Jobst"}]} 
SRT |a TRIPHANSIMDESIGNANDA5201