Iodine removal in intravenous dual-energy CT-cholangiography: is virtual non-enhanced imaging effective to replace true non-enhanced imaging?
Purpose: To evaluate whether virtual non-enhanced imaging (VNI) is effective to replace true non-enhanced imaging (TNI) applying iodine removal in intravenous dual-energy CT-cholangiography. Materials and Methods: From April 2009 until February 2010, fifteen potential donors for living-related liver...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2012
|
| In: |
European journal of radiology
Year: 2011, Jahrgang: 81, Heft: 4, Pages: 692-699 |
| ISSN: | 1872-7727 |
| DOI: | 10.1016/j.ejrad.2011.01.087 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1016/j.ejrad.2011.01.087 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X11001276 |
| Verfasserangaben: | Christof M. Sommer, Christoph B. Schwarzwaelder, Wolfram Stiller, Sebastian T. Schindera, Ulrike Stampfl, Nadine Bellemann, Maria Holzschuh, Jan Schmidt, Juergen Weitz, Lars Grenacher, Hans U. Kauczor, Boris A. Radeleff |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 157796103X | ||
| 003 | DE-627 | ||
| 005 | 20220814201736.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180726r20122011xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejrad.2011.01.087 |2 doi | |
| 035 | |a (DE-627)157796103X | ||
| 035 | |a (DE-576)50796103X | ||
| 035 | |a (DE-599)BSZ50796103X | ||
| 035 | |a (OCoLC)1341014545 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Sommer, Christof-Matthias |d 1978- |e VerfasserIn |0 (DE-588)133929701 |0 (DE-627)558738699 |0 (DE-576)278278035 |4 aut | |
| 245 | 1 | 0 | |a Iodine removal in intravenous dual-energy CT-cholangiography |b is virtual non-enhanced imaging effective to replace true non-enhanced imaging? |c Christof M. Sommer, Christoph B. Schwarzwaelder, Wolfram Stiller, Sebastian T. Schindera, Ulrike Stampfl, Nadine Bellemann, Maria Holzschuh, Jan Schmidt, Juergen Weitz, Lars Grenacher, Hans U. Kauczor, Boris A. Radeleff |
| 264 | 1 | |c 2012 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 24 February 2011 | ||
| 500 | |a Gesehen am 26.07.2018 | ||
| 520 | |a Purpose: To evaluate whether virtual non-enhanced imaging (VNI) is effective to replace true non-enhanced imaging (TNI) applying iodine removal in intravenous dual-energy CT-cholangiography. Materials and Methods: From April 2009 until February 2010, fifteen potential donors for living-related liver transplantation (mean age 37.6±10.8 years) were included. Potential donors underwent a two-phase CT-examination of the liver. The first phase consisted of a single-energy non-enhanced CT-acquisition that provided TNI. After administration of hepatobiliary contrast agent, the second phase was performed as a dual-energy cholangiographic CT-acquisition. This provided VNI. Objective image quality (attenuation values [bile ducts and liver parenchyma] and contrast-to-noise ratio) and subjective overall image quality (1 - excellent; 5 - non diagnostic) were evaluated. Effective radiation dose was compared. Results: For TNI and VNI, attenuation values for bile ducts were 16.8±11.2HU and 5.5±17.0HU (p<0.05) and for liver parenchyma 55.3±8.4HU and 58.1±10.6HU (n.s.). For TNI and VNI, contrast-to-noise ratio was 2.6±0.6HU and 6.9±2.1HU (p<0.001). For VNI, subjective overall image quality was 1 in ten datasets, 2 in four datasets and 3 in one dataset. Effective radiation dose for the dual-energy cholangiographic CT-acquisition was 3.6±0.9mSv and for two-phase single-energy CT-cholangiography 5.1±1.3mSv (p<0.001). Conclusion: In this study on iodine removal in intravenous dual-energy CT-cholangiography, subjective image quality is equivalent, contrast-to-noise ratio is improved and effective radiation dose is reduced when VNI is performed. The differences between TNI and VNI with respect to attenuation values seem to have limited clinical relevance and therefore we consider VNI as effective to replace TNI. | ||
| 534 | |c 2011 | ||
| 650 | 4 | |a Cholangiography | |
| 650 | 4 | |a CT | |
| 650 | 4 | |a Dual-energy | |
| 650 | 4 | |a Iodine removal | |
| 650 | 4 | |a Virtual non-enhanced images | |
| 700 | 1 | |a Schwarzwälder, Christoph Bernhard |d 1985- |e VerfasserIn |0 (DE-588)104466763X |0 (DE-627)772405050 |0 (DE-576)398025231 |4 aut | |
| 700 | 1 | |a Stiller, Wolfram |d 1976- |e VerfasserIn |0 (DE-588)105822672X |0 (DE-627)796627495 |0 (DE-576)414249496 |4 aut | |
| 700 | 1 | |a Stampfl, Ulrike |d 1978- |e VerfasserIn |0 (DE-588)132557711 |0 (DE-627)523645104 |0 (DE-576)261999664 |4 aut | |
| 700 | 1 | |a Bellemann, Nadine |d 1982- |e VerfasserIn |0 (DE-588)140128069 |0 (DE-627)616037562 |0 (DE-576)314703993 |4 aut | |
| 700 | 1 | |a Holzschuh, Maria |e VerfasserIn |0 (DE-588)1081662018 |0 (DE-627)846455404 |0 (DE-576)454640412 |4 aut | |
| 700 | 1 | |a Schmidt, Jan |d 1961- |e VerfasserIn |0 (DE-588)1022937995 |0 (DE-627)717335852 |0 (DE-576)366198017 |4 aut | |
| 700 | 1 | |a Weitz, Jürgen |e VerfasserIn |0 (DE-588)1022345974 |0 (DE-627)716954451 |0 (DE-576)171632176 |4 aut | |
| 700 | 1 | |a Grenacher, Lars |d 1967- |e VerfasserIn |0 (DE-588)115424598 |0 (DE-627)691308977 |0 (DE-576)289876761 |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Radeleff, Boris |d 1969- |e VerfasserIn |0 (DE-588)123910846 |0 (DE-627)706470826 |0 (DE-576)293938504 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t European journal of radiology |d Amsterdam [u.a.] : Elsevier Science, 1990 |g 81(2012), 4, Seite 692-699 |h Online-Ressource |w (DE-627)32044483X |w (DE-600)2005350-2 |w (DE-576)099718138 |x 1872-7727 |7 nnas |a Iodine removal in intravenous dual-energy CT-cholangiography is virtual non-enhanced imaging effective to replace true non-enhanced imaging? |
| 773 | 1 | 8 | |g volume:81 |g year:2012 |g number:4 |g pages:692-699 |g extent:8 |a Iodine removal in intravenous dual-energy CT-cholangiography is virtual non-enhanced imaging effective to replace true non-enhanced imaging? |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.ejrad.2011.01.087 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0720048X11001276 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180726 | ||
| 993 | |a Article | ||
| 994 | |a 2012 | ||
| 998 | |g 123910846 |a Radeleff, Boris |m 123910846:Radeleff, Boris |d 910000 |d 911400 |e 910000PR123910846 |e 911400PR123910846 |k 0/910000/ |k 1/910000/911400/ |p 12 |y j | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 11 | ||
| 998 | |g 115424598 |a Grenacher, Lars |m 115424598:Grenacher, Lars |d 910000 |d 911400 |e 910000PG115424598 |e 911400PG115424598 |k 0/910000/ |k 1/910000/911400/ |p 10 | ||
| 998 | |g 1022345974 |a Weitz, Jürgen |m 1022345974:Weitz, Jürgen |d 910000 |d 910200 |e 910000PW1022345974 |e 910200PW1022345974 |k 0/910000/ |k 1/910000/910200/ |p 9 | ||
| 998 | |g 1022937995 |a Schmidt, Jan |m 1022937995:Schmidt, Jan |d 50000 |e 50000PS1022937995 |k 0/50000/ |p 8 | ||
| 998 | |g 1081662018 |a Holzschuh, Maria |m 1081662018:Holzschuh, Maria |d 910000 |d 911400 |e 910000PH1081662018 |e 911400PH1081662018 |k 0/910000/ |k 1/910000/911400/ |p 7 | ||
| 998 | |g 140128069 |a Bellemann, Nadine |m 140128069:Bellemann, Nadine |d 910000 |d 911400 |e 910000PB140128069 |e 911400PB140128069 |k 0/910000/ |k 1/910000/911400/ |p 6 | ||
| 998 | |g 132557711 |a Stampfl, Ulrike |m 132557711:Stampfl, Ulrike |d 910000 |d 911400 |e 910000PS132557711 |e 911400PS132557711 |k 0/910000/ |k 1/910000/911400/ |p 5 | ||
| 998 | |g 105822672X |a Stiller, Wolfram |m 105822672X:Stiller, Wolfram |d 910000 |d 911400 |e 910000PS105822672X |e 911400PS105822672X |k 0/910000/ |k 1/910000/911400/ |p 3 | ||
| 998 | |g 104466763X |a Schwarzwälder, Christoph Bernhard |m 104466763X:Schwarzwälder, Christoph Bernhard |d 910000 |d 911400 |e 910000PS104466763X |e 911400PS104466763X |k 0/910000/ |k 1/910000/911400/ |p 2 | ||
| 998 | |g 133929701 |a Sommer, Christof-Matthias |m 133929701:Sommer, Christof-Matthias |d 910000 |d 911400 |e 910000PS133929701 |e 911400PS133929701 |k 0/910000/ |k 1/910000/911400/ |p 1 |x j | ||
| 999 | |a KXP-PPN157796103X |e 3019547075 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["Christof M. Sommer, Christoph B. Schwarzwaelder, Wolfram Stiller, Sebastian T. Schindera, Ulrike Stampfl, Nadine Bellemann, Maria Holzschuh, Jan Schmidt, Juergen Weitz, Lars Grenacher, Hans U. Kauczor, Boris A. Radeleff"]},"id":{"doi":["10.1016/j.ejrad.2011.01.087"],"eki":["157796103X"]},"recId":"157796103X","physDesc":[{"extent":"8 S."}],"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2012"}],"person":[{"display":"Sommer, Christof-Matthias","family":"Sommer","given":"Christof-Matthias","role":"aut"},{"display":"Schwarzwälder, Christoph Bernhard","family":"Schwarzwälder","given":"Christoph Bernhard","role":"aut"},{"role":"aut","given":"Wolfram","family":"Stiller","display":"Stiller, Wolfram"},{"display":"Stampfl, Ulrike","given":"Ulrike","role":"aut","family":"Stampfl"},{"display":"Bellemann, Nadine","role":"aut","given":"Nadine","family":"Bellemann"},{"role":"aut","given":"Maria","family":"Holzschuh","display":"Holzschuh, Maria"},{"display":"Schmidt, Jan","role":"aut","given":"Jan","family":"Schmidt"},{"family":"Weitz","role":"aut","given":"Jürgen","display":"Weitz, Jürgen"},{"role":"aut","given":"Lars","family":"Grenacher","display":"Grenacher, Lars"},{"given":"Hans-Ulrich","role":"aut","family":"Kauczor","display":"Kauczor, Hans-Ulrich"},{"display":"Radeleff, Boris","family":"Radeleff","role":"aut","given":"Boris"}],"relHost":[{"disp":"Iodine removal in intravenous dual-energy CT-cholangiography is virtual non-enhanced imaging effective to replace true non-enhanced imaging?European journal of radiology","physDesc":[{"extent":"Online-Ressource"}],"recId":"32044483X","language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 05.02.20"],"title":[{"subtitle":"EJR","title_sort":"European journal of radiology","title":"European journal of radiology"}],"origin":[{"dateIssuedDisp":"1990-","dateIssuedKey":"1990","publisherPlace":"Amsterdam [u.a.]","publisher":"Elsevier Science"}],"id":{"issn":["1872-7727"],"eki":["32044483X"],"zdb":["2005350-2"]},"part":{"extent":"8","text":"81(2012), 4, Seite 692-699","issue":"4","pages":"692-699","volume":"81","year":"2012"},"titleAlt":[{"title":"EJR"}],"pubHistory":["Nachgewiesen 10.1990 -"]}],"title":[{"title_sort":"Iodine removal in intravenous dual-energy CT-cholangiography","title":"Iodine removal in intravenous dual-energy CT-cholangiography","subtitle":"is virtual non-enhanced imaging effective to replace true non-enhanced imaging?"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Available online 24 February 2011","Gesehen am 26.07.2018"]} | ||
| SRT | |a SOMMERCHRIIODINEREMO2012 | ||