Investigation of mixed ion fields in the forward direction for 220.5 MeV/u helium ion beams: comparison between water and PMMA targets

Currently there is a rising interest in helium ion beams for radiotherapy. For benchmarking of the physical beam models used in treatment planning, there is a need for experimental data on the composition and spatial distribution of mixed ion fields. Of particular interest are the attenuation of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Aricó, Giulia (VerfasserIn) , Gehrke, Tim (VerfasserIn) , Jäkel, Oliver (VerfasserIn) , Mairani, Andrea (VerfasserIn) , Martišíková, Mária (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 3 October 2017
In: Physics in medicine and biology
Year: 2017, Jahrgang: 62, Heft: 20, Pages: 8003-8024
ISSN:1361-6560
DOI:10.1088/1361-6560/aa875e
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1088/1361-6560/aa875e
Volltext
Verfasserangaben:G. Aricó, T. Gehrke, J. Jakubek, R. Gallas, S. Berke, O. Jäkel, A. Mairani, A. Ferrari and M. Martišíková

MARC

LEADER 00000caa a2200000 c 4500
001 1577980824
003 DE-627
005 20230426230754.0
007 cr uuu---uuuuu
008 180726s2017 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/aa875e  |2 doi 
035 |a (DE-627)1577980824 
035 |a (DE-576)507980824 
035 |a (DE-599)BSZ507980824 
035 |a (OCoLC)1341014568 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Aricó, Giulia  |e VerfasserIn  |0 (DE-588)1121320783  |0 (DE-627)874240158  |0 (DE-576)480812632  |4 aut 
245 1 0 |a Investigation of mixed ion fields in the forward direction for 220.5 MeV/u helium ion beams  |b comparison between water and PMMA targets  |c G. Aricó, T. Gehrke, J. Jakubek, R. Gallas, S. Berke, O. Jäkel, A. Mairani, A. Ferrari and M. Martišíková 
264 1 |c 3 October 2017 
300 |a 22 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 26.07.2018 
520 |a Currently there is a rising interest in helium ion beams for radiotherapy. For benchmarking of the physical beam models used in treatment planning, there is a need for experimental data on the composition and spatial distribution of mixed ion fields. Of particular interest are the attenuation of the primary helium ion fluence and the build-up of secondary hydrogen ions due to nuclear interactions. The aim of this work was to provide such data with an enhanced precision. Moreover, the validity and limits of the mixed ion field equivalence between water and PMMA targets were investigated. Experiments with a 220.5 MeV/u helium ion pencil beam were performed at the Heidelberg Ion-Beam Therapy Center in Germany. The compact detection system used for ion tracking and identification was solely based on Timepix position-sensitive semiconductor detectors. In comparison to standard techniques, this system is two orders of magnitude smaller, and provides higher precision and flexibility. The numbers of outgoing helium and hydrogen ions per primary helium ion as well as the lateral particle distributions were quantitatively investigated in the forward direction behind water and PMMA targets with 5.2-18 cm water equivalent thickness (WET). Comparing water and PMMA targets with the same WET, we found that significant differences in the amount of outgoing helium and hydrogen ions and in the lateral particle distributions arise for target thicknesses above 10 cm WET. The experimental results concerning hydrogen ions emerging from the targets were reproduced reasonably well by Monte Carlo simulations using the FLUKA code. Concerning the amount of outgoing helium ions, significant differences of 3-15% were found between experiments and simulations. We conclude that if PMMA is used in place of water in dosimetry, differences in the dose distributions could arise close to the edges of the field, in particular for deep seated targets. 
650 4 |a Germany 
650 4 |a Helium 
650 4 |a Humans 
650 4 |a Models, Theoretical 
650 4 |a Monte Carlo Method 
650 4 |a Phantoms, Imaging 
650 4 |a Polymethyl Methacrylate 
650 4 |a Protons 
650 4 |a Radiometry 
650 4 |a Radiotherapy Dosage 
650 4 |a Radiotherapy Planning, Computer-Assisted 
650 4 |a Water 
700 1 |a Gehrke, Tim  |d 1986-  |e VerfasserIn  |0 (DE-588)1044696982  |0 (DE-627)772571627  |0 (DE-576)398073740  |4 aut 
700 1 |a Jäkel, Oliver  |d 1964-  |e VerfasserIn  |0 (DE-588)1050056302  |0 (DE-627)783260709  |0 (DE-576)404358705  |4 aut 
700 1 |a Mairani, Andrea  |e VerfasserIn  |0 (DE-588)1116742179  |0 (DE-627)870669281  |0 (DE-576)478592493  |4 aut 
700 1 |a Martišíková, Mária  |d 1979-  |e VerfasserIn  |0 (DE-588)1076839649  |0 (DE-627)835386767  |0 (DE-576)252899369  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 62(2017), 20, Seite 8003-8024  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Investigation of mixed ion fields in the forward direction for 220.5 MeV/u helium ion beams comparison between water and PMMA targets 
773 1 8 |g volume:62  |g year:2017  |g number:20  |g pages:8003-8024  |g extent:22  |a Investigation of mixed ion fields in the forward direction for 220.5 MeV/u helium ion beams comparison between water and PMMA targets 
856 4 0 |u http://dx.doi.org/10.1088/1361-6560/aa875e  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20180726 
993 |a Article 
994 |a 2017 
998 |g 1076839649  |a Martišíková, Mária  |m 1076839649:Martišíková, Mária  |d 50000  |e 50000PM1076839649  |k 0/50000/  |p 9  |y j 
998 |g 1116742179  |a Mairani, Andrea  |m 1116742179:Mairani, Andrea  |d 910000  |d 950000  |d 950400  |e 910000PM1116742179  |e 950000PM1116742179  |e 950400PM1116742179  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 7 
998 |g 1050056302  |a Jäkel, Oliver  |m 1050056302:Jäkel, Oliver  |d 910000  |d 911400  |e 910000PJ1050056302  |e 911400PJ1050056302  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 1044696982  |a Gehrke, Tim  |m 1044696982:Gehrke, Tim  |d 50000  |e 50000PG1044696982  |k 0/50000/  |p 2 
998 |g 1121320783  |a Aricó, Giulia  |m 1121320783:Aricó, Giulia  |d 910000  |d 911400  |e 910000PA1121320783  |e 911400PA1121320783  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1577980824  |e 3019582784 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1577980824"],"doi":["10.1088/1361-6560/aa875e"]},"name":{"displayForm":["G. Aricó, T. Gehrke, J. Jakubek, R. Gallas, S. Berke, O. Jäkel, A. Mairani, A. Ferrari and M. Martišíková"]},"recId":"1577980824","physDesc":[{"extent":"22 S."}],"title":[{"title":"Investigation of mixed ion fields in the forward direction for 220.5 MeV/u helium ion beams","title_sort":"Investigation of mixed ion fields in the forward direction for 220.5 MeV/u helium ion beams","subtitle":"comparison between water and PMMA targets"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 26.07.2018"],"origin":[{"dateIssuedDisp":"3 October 2017","dateIssuedKey":"2017"}],"person":[{"family":"Aricó","given":"Giulia","role":"aut","display":"Aricó, Giulia"},{"display":"Gehrke, Tim","family":"Gehrke","role":"aut","given":"Tim"},{"family":"Jäkel","given":"Oliver","role":"aut","display":"Jäkel, Oliver"},{"family":"Mairani","given":"Andrea","role":"aut","display":"Mairani, Andrea"},{"role":"aut","given":"Mária","family":"Martišíková","display":"Martišíková, Mária"}],"relHost":[{"recId":"269016163","physDesc":[{"extent":"Online-Ressource"}],"disp":"Investigation of mixed ion fields in the forward direction for 220.5 MeV/u helium ion beams comparison between water and PMMA targetsPhysics in medicine and biology","pubHistory":["1.1956 -"],"origin":[{"dateIssuedDisp":"1956-","dateIssuedKey":"1956","publisherPlace":"Bristol","publisher":"IOP Publ."}],"part":{"pages":"8003-8024","text":"62(2017), 20, Seite 8003-8024","extent":"22","issue":"20","year":"2017","volume":"62"},"title":[{"title_sort":"Physics in medicine and biology","title":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine"}],"id":{"zdb":["1473501-5"],"issn":["1361-6560"],"eki":["269016163"]},"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"]}]} 
SRT |a ARICOGIULIINVESTIGAT3201