The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty

Background Mechanical loosening is the most common cause of revision in unicompartmental knee arthroplasty. We determined the effect of bone lavage on tibial cement penetration and interface temperature with controlled ligament tension forces. We presumed pulsed lavage would allow increased cement p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Clarius, Michael (VerfasserIn) , Seeger, Jörn Bengt (VerfasserIn) , Jäger, Sebastian (VerfasserIn) , Bitsch, Rudi G. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2012
In: Clinical biomechanics
Year: 2012, Jahrgang: 27, Heft: 4, Pages: 372-376
ISSN:1879-1271
DOI:10.1016/j.clinbiomech.2011.10.006
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.clinbiomech.2011.10.006
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0268003311002646
Volltext
Verfasserangaben:M. Clarius, J.B. Seeger, S. Jaeger, G. Mohr, R.G. Bitsch

MARC

LEADER 00000caa a2200000 c 4500
001 1578260906
003 DE-627
005 20220814205903.0
007 cr uuu---uuuuu
008 180806s2012 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.clinbiomech.2011.10.006  |2 doi 
035 |a (DE-627)1578260906 
035 |a (DE-576)508260906 
035 |a (DE-599)BSZ508260906 
035 |a (OCoLC)1341016298 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Clarius, Michael  |e VerfasserIn  |0 (DE-588)1075391903  |0 (DE-627)833263951  |0 (DE-576)176466533  |4 aut 
245 1 4 |a The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty  |c M. Clarius, J.B. Seeger, S. Jaeger, G. Mohr, R.G. Bitsch 
264 1 |c 2012 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 1 November 2011 
500 |a Gesehen am 06.08.2018 
520 |a Background Mechanical loosening is the most common cause of revision in unicompartmental knee arthroplasty. We determined the effect of bone lavage on tibial cement penetration and interface temperature with controlled ligament tension forces. We presumed pulsed lavage would allow increased cement penetration compared with syringe lavage. Methods Cemented unicompartmental knee arthroplasty was performed in 12 pairs of fresh-frozen knees. Lavage was performed using pulsed lavage on one side (A) and syringe lavage on the other (B). Cement penetration pressure, interface temperature, and ligament tension forces were continuously monitored during the operation. Screened radiographs were taken and cement penetration under the tibial plateau was measured. Findings The pulsed lavage group showed a mean cement penetration area of 187.24 (SD 36.37) mm², whereas 144.29 (SD 35.74) mm2 was measured in the group with syringe lavage. Cement penetration pressure was 13.29 (SD 8.69) kPa in Group A and 20.21 (SD 7.78) kPa in Group B. Maximum interface temperatures of 46.99°C were observed in Group A and 45.02°C in Group B. Interpretation Our data showed pulsed lavage cleansing of the cancellous tibial bone substantially improved cement penetration compared with syringe lavage without reaching the temperature threshold for bone necrosis. We recommend the routine use of pulsed lavage to improve long-term fixation. 
650 4 |a Cement penetration 
650 4 |a Ligament tension force 
650 4 |a Pulsed lavage 
650 4 |a Unicompartmental 
700 1 |a Seeger, Jörn Bengt  |d 1980-  |e VerfasserIn  |0 (DE-588)139009272  |0 (DE-627)703179659  |0 (DE-576)309896347  |4 aut 
700 1 |a Jäger, Sebastian  |d 1975-  |e VerfasserIn  |0 (DE-588)1059313731  |0 (DE-627)79828238X  |0 (DE-576)415306647  |4 aut 
700 1 |a Bitsch, Rudi G.  |d 1970-  |e VerfasserIn  |0 (DE-588)131490060  |0 (DE-627)50981378X  |0 (DE-576)298541726  |4 aut 
773 0 8 |i Enthalten in  |t Clinical biomechanics  |d Amsterdam [u.a.] : Elsevier Science, 1986  |g 27(2012), 4, Seite 372-376  |h Online-Ressource  |w (DE-627)32043740X  |w (DE-600)2004518-9  |w (DE-576)261823612  |x 1879-1271  |7 nnas  |a The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty 
773 1 8 |g volume:27  |g year:2012  |g number:4  |g pages:372-376  |g extent:5  |a The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty 
856 4 0 |u http://dx.doi.org/10.1016/j.clinbiomech.2011.10.006  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0268003311002646  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180806 
993 |a Article 
994 |a 2012 
998 |g 131490060  |a Bitsch, Rudi G.  |m 131490060:Bitsch, Rudi G.  |d 910000  |d 911460  |e 910000PB131490060  |e 911460PB131490060  |k 0/910000/  |k 1/910000/911460/  |p 5  |y j 
998 |g 1059313731  |a Jäger, Sebastian  |m 1059313731:Jäger, Sebastian  |d 910000  |d 911460  |e 910000PJ1059313731  |e 911460PJ1059313731  |k 0/910000/  |k 1/910000/911460/  |p 3 
998 |g 139009272  |a Seeger, Jörn Bengt  |m 139009272:Seeger, Jörn Bengt  |p 2 
998 |g 1075391903  |a Clarius, Michael  |m 1075391903:Clarius, Michael  |d 910000  |d 911460  |e 910000PC1075391903  |e 911460PC1075391903  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1578260906  |e 3020238277 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"title":[{"title_sort":"importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty","title":"The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty"}],"person":[{"role":"aut","given":"Michael","display":"Clarius, Michael","family":"Clarius"},{"role":"aut","given":"Jörn Bengt","display":"Seeger, Jörn Bengt","family":"Seeger"},{"given":"Sebastian","display":"Jäger, Sebastian","family":"Jäger","role":"aut"},{"family":"Bitsch","given":"Rudi G.","display":"Bitsch, Rudi G.","role":"aut"}],"recId":"1578260906","name":{"displayForm":["M. Clarius, J.B. Seeger, S. Jaeger, G. Mohr, R.G. Bitsch"]},"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2012"}],"relHost":[{"note":["Gesehen am 04.02.20"],"part":{"volume":"27","text":"27(2012), 4, Seite 372-376","year":"2012","pages":"372-376","extent":"5","issue":"4"},"id":{"zdb":["2004518-9"],"issn":["1879-1271"],"eki":["32043740X"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Clinical biomechanics","subtitle":"a journal affiliated to the International Society of Biomechanics and the American Society of Biomechanics","title":"Clinical biomechanics"}],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1986","dateIssuedDisp":"1986-","publisher":"Elsevier Science"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.1986 -"],"language":["eng"],"recId":"32043740X","disp":"The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplastyClinical biomechanics"}],"note":["Available online 1 November 2011","Gesehen am 06.08.2018"],"physDesc":[{"extent":"5 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1578260906"],"doi":["10.1016/j.clinbiomech.2011.10.006"]}} 
SRT |a CLARIUSMICIMPORTANCE2012