The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty
Background Mechanical loosening is the most common cause of revision in unicompartmental knee arthroplasty. We determined the effect of bone lavage on tibial cement penetration and interface temperature with controlled ligament tension forces. We presumed pulsed lavage would allow increased cement p...
Gespeichert in:
| Hauptverfasser: | , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2012
|
| In: |
Clinical biomechanics
Year: 2012, Jahrgang: 27, Heft: 4, Pages: 372-376 |
| ISSN: | 1879-1271 |
| DOI: | 10.1016/j.clinbiomech.2011.10.006 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1016/j.clinbiomech.2011.10.006 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0268003311002646 |
| Verfasserangaben: | M. Clarius, J.B. Seeger, S. Jaeger, G. Mohr, R.G. Bitsch |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1578260906 | ||
| 003 | DE-627 | ||
| 005 | 20220814205903.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180806s2012 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.clinbiomech.2011.10.006 |2 doi | |
| 035 | |a (DE-627)1578260906 | ||
| 035 | |a (DE-576)508260906 | ||
| 035 | |a (DE-599)BSZ508260906 | ||
| 035 | |a (OCoLC)1341016298 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Clarius, Michael |e VerfasserIn |0 (DE-588)1075391903 |0 (DE-627)833263951 |0 (DE-576)176466533 |4 aut | |
| 245 | 1 | 4 | |a The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty |c M. Clarius, J.B. Seeger, S. Jaeger, G. Mohr, R.G. Bitsch |
| 264 | 1 | |c 2012 | |
| 300 | |a 5 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 1 November 2011 | ||
| 500 | |a Gesehen am 06.08.2018 | ||
| 520 | |a Background Mechanical loosening is the most common cause of revision in unicompartmental knee arthroplasty. We determined the effect of bone lavage on tibial cement penetration and interface temperature with controlled ligament tension forces. We presumed pulsed lavage would allow increased cement penetration compared with syringe lavage. Methods Cemented unicompartmental knee arthroplasty was performed in 12 pairs of fresh-frozen knees. Lavage was performed using pulsed lavage on one side (A) and syringe lavage on the other (B). Cement penetration pressure, interface temperature, and ligament tension forces were continuously monitored during the operation. Screened radiographs were taken and cement penetration under the tibial plateau was measured. Findings The pulsed lavage group showed a mean cement penetration area of 187.24 (SD 36.37) mm², whereas 144.29 (SD 35.74) mm2 was measured in the group with syringe lavage. Cement penetration pressure was 13.29 (SD 8.69) kPa in Group A and 20.21 (SD 7.78) kPa in Group B. Maximum interface temperatures of 46.99°C were observed in Group A and 45.02°C in Group B. Interpretation Our data showed pulsed lavage cleansing of the cancellous tibial bone substantially improved cement penetration compared with syringe lavage without reaching the temperature threshold for bone necrosis. We recommend the routine use of pulsed lavage to improve long-term fixation. | ||
| 650 | 4 | |a Cement penetration | |
| 650 | 4 | |a Ligament tension force | |
| 650 | 4 | |a Pulsed lavage | |
| 650 | 4 | |a Unicompartmental | |
| 700 | 1 | |a Seeger, Jörn Bengt |d 1980- |e VerfasserIn |0 (DE-588)139009272 |0 (DE-627)703179659 |0 (DE-576)309896347 |4 aut | |
| 700 | 1 | |a Jäger, Sebastian |d 1975- |e VerfasserIn |0 (DE-588)1059313731 |0 (DE-627)79828238X |0 (DE-576)415306647 |4 aut | |
| 700 | 1 | |a Bitsch, Rudi G. |d 1970- |e VerfasserIn |0 (DE-588)131490060 |0 (DE-627)50981378X |0 (DE-576)298541726 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Clinical biomechanics |d Amsterdam [u.a.] : Elsevier Science, 1986 |g 27(2012), 4, Seite 372-376 |h Online-Ressource |w (DE-627)32043740X |w (DE-600)2004518-9 |w (DE-576)261823612 |x 1879-1271 |7 nnas |a The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty |
| 773 | 1 | 8 | |g volume:27 |g year:2012 |g number:4 |g pages:372-376 |g extent:5 |a The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.clinbiomech.2011.10.006 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0268003311002646 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180806 | ||
| 993 | |a Article | ||
| 994 | |a 2012 | ||
| 998 | |g 131490060 |a Bitsch, Rudi G. |m 131490060:Bitsch, Rudi G. |d 910000 |d 911460 |e 910000PB131490060 |e 911460PB131490060 |k 0/910000/ |k 1/910000/911460/ |p 5 |y j | ||
| 998 | |g 1059313731 |a Jäger, Sebastian |m 1059313731:Jäger, Sebastian |d 910000 |d 911460 |e 910000PJ1059313731 |e 911460PJ1059313731 |k 0/910000/ |k 1/910000/911460/ |p 3 | ||
| 998 | |g 139009272 |a Seeger, Jörn Bengt |m 139009272:Seeger, Jörn Bengt |p 2 | ||
| 998 | |g 1075391903 |a Clarius, Michael |m 1075391903:Clarius, Michael |d 910000 |d 911460 |e 910000PC1075391903 |e 911460PC1075391903 |k 0/910000/ |k 1/910000/911460/ |p 1 |x j | ||
| 999 | |a KXP-PPN1578260906 |e 3020238277 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"title":[{"title_sort":"importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty","title":"The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty"}],"person":[{"role":"aut","given":"Michael","display":"Clarius, Michael","family":"Clarius"},{"role":"aut","given":"Jörn Bengt","display":"Seeger, Jörn Bengt","family":"Seeger"},{"given":"Sebastian","display":"Jäger, Sebastian","family":"Jäger","role":"aut"},{"family":"Bitsch","given":"Rudi G.","display":"Bitsch, Rudi G.","role":"aut"}],"recId":"1578260906","name":{"displayForm":["M. Clarius, J.B. Seeger, S. Jaeger, G. Mohr, R.G. Bitsch"]},"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2012"}],"relHost":[{"note":["Gesehen am 04.02.20"],"part":{"volume":"27","text":"27(2012), 4, Seite 372-376","year":"2012","pages":"372-376","extent":"5","issue":"4"},"id":{"zdb":["2004518-9"],"issn":["1879-1271"],"eki":["32043740X"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Clinical biomechanics","subtitle":"a journal affiliated to the International Society of Biomechanics and the American Society of Biomechanics","title":"Clinical biomechanics"}],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1986","dateIssuedDisp":"1986-","publisher":"Elsevier Science"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.1986 -"],"language":["eng"],"recId":"32043740X","disp":"The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplastyClinical biomechanics"}],"note":["Available online 1 November 2011","Gesehen am 06.08.2018"],"physDesc":[{"extent":"5 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1578260906"],"doi":["10.1016/j.clinbiomech.2011.10.006"]}} | ||
| SRT | |a CLARIUSMICIMPORTANCE2012 | ||