Validity, test-retest reliability, sensitivity to change and feasibility of motor-cognitive dual task assessments in patients with dementia
Objective: To investigate validity, test-retest reliability, sensitivity to change, and feasibility of dual task (DT) assessments in patients with dementia. - Design - Validation study. - Setting - Post ward-rehabilitation. - Participants - Geriatric patients (n=105) with dementia (age 82.7±5.9, MMS...
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
30 January 2017
|
| In: |
Archives of gerontology and geriatrics
Year: 2017, Volume: 70, Pages: 169-179 |
| ISSN: | 1872-6976 |
| DOI: | 10.1016/j.archger.2017.01.016 |
| Online Access: | Verlag, Volltext: http://dx.doi.org/10.1016/j.archger.2017.01.016 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S016749431730081X |
| Author Notes: | Nele C. Lemke, Stefanie Wiloth, Christian Werner, Klaus Hauer |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1578444659 | ||
| 003 | DE-627 | ||
| 005 | 20220814213845.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180809s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.archger.2017.01.016 |2 doi | |
| 035 | |a (DE-627)1578444659 | ||
| 035 | |a (DE-576)508444659 | ||
| 035 | |a (DE-599)BSZ508444659 | ||
| 035 | |a (OCoLC)1341016674 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Lemke, Nele |d 1984- |e VerfasserIn |0 (DE-588)1096352192 |0 (DE-627)856720593 |0 (DE-576)467995338 |4 aut | |
| 245 | 1 | 0 | |a Validity, test-retest reliability, sensitivity to change and feasibility of motor-cognitive dual task assessments in patients with dementia |c Nele C. Lemke, Stefanie Wiloth, Christian Werner, Klaus Hauer |
| 264 | 1 | |c 30 January 2017 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 30 January 2017 | ||
| 500 | |a Gesehen am 09.08.2018 | ||
| 520 | |a Objective: To investigate validity, test-retest reliability, sensitivity to change, and feasibility of dual task (DT) assessments in patients with dementia. - Design - Validation study. - Setting - Post ward-rehabilitation. - Participants - Geriatric patients (n=105) with dementia (age 82.7±5.9, MMSE score 21.9). - Main outcome measures - Psychometric quality of DT performance of different DT-tests. Analyses were performed for motor and cognitive performance, and relative DT costs (DTCs). - Results - Spearman’s rank correlations (rs) between examined DT-tests were moderate-high for motor tasks (rs=0.29-0.90), small-high for cognitive tasks (rs=0.12-0.55) and small-high for relative DTCs (motor DTCs rs=0.02-0.61, cognitive DTCs rs=−0.19 to 0.06, combined DTCs rs=−0.11 to 0.31). Correlations with external assessment were moderate-high for motor tasks (rs=0.25-0.84), small-moderate for cognitive tasks (rs=−0.10 to 0.46) and small-moderate for relative DTCs (motor DTCs rs=−0.09 to 0.17, cognitive DTCs rs=−0.03 to 0.21, combined DTCs rs=−0.07 to 0.26). Test-retest reliability was excellent for motor tasks (ICC=0.75-0.96), fair-excellent for cognitive tasks (ICC=0.51-0.88) and poor-good for relative DTCs (motor DTCs ICC=0.10-0.74, cognitive DTCs ICC=0.05-0.65, combined DTCs ICC=0.15-0.71). Sensitivity to change was acceptable-excellent for trained DT-tests (p≤0.01). Effect sizes were small-large for gait parameters (SRM=0.30-1.12), large for cognitive tasks (SRM=0.82-0.95) and small-large for relative DTCs (motor DTCs SRM=0.15-0.77, cognitive DTCs SRM=0.56-0.98, combined DTCs SRM=0.40-1.10). Completion time ranged from 13.1 to 16.9min. - Conclusions - All DT-tests showed acceptable-excellent psychometric properties in patients with dementia with highest quality for the gait-based tests ‘Walking & Counting’ and ‘Walking & reciting ABC’. | ||
| 650 | 4 | |a Assessment validation | |
| 650 | 4 | |a Cognition | |
| 650 | 4 | |a Dementia | |
| 650 | 4 | |a Dual task | |
| 650 | 4 | |a Elderly | |
| 700 | 1 | |a Wiloth, Stefanie |d 1985- |e VerfasserIn |0 (DE-588)1082151173 |0 (DE-627)847175782 |0 (DE-576)455146624 |4 aut | |
| 700 | 1 | |a Werner, Christian |d 1984- |e VerfasserIn |0 (DE-588)1152967037 |0 (DE-627)101432341X |0 (DE-576)499961897 |4 aut | |
| 700 | 1 | |a Hauer, Klaus |d 1956- |e VerfasserIn |0 (DE-588)172602270 |0 (DE-627)697537048 |0 (DE-576)13346167X |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Archives of gerontology and geriatrics |d Amsterdam [u.a.] : Elsevier Science, 1982 |g 70(2017), Seite 169-179 |h Online-Ressource |w (DE-627)320639312 |w (DE-600)2024857-X |w (DE-576)256155429 |x 1872-6976 |7 nnas |a Validity, test-retest reliability, sensitivity to change and feasibility of motor-cognitive dual task assessments in patients with dementia |
| 773 | 1 | 8 | |g volume:70 |g year:2017 |g pages:169-179 |g extent:11 |a Validity, test-retest reliability, sensitivity to change and feasibility of motor-cognitive dual task assessments in patients with dementia |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.archger.2017.01.016 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S016749431730081X |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180809 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 172602270 |a Hauer, Klaus |m 172602270:Hauer, Klaus |d 50000 |e 50000PH172602270 |k 0/50000/ |p 4 |y j | ||
| 998 | |g 1152967037 |a Werner, Christian |m 1152967037:Werner, Christian |d 50000 |e 50000PW1152967037 |k 0/50000/ |p 3 | ||
| 998 | |g 1082151173 |a Wiloth, Stefanie |m 1082151173:Wiloth, Stefanie |d 120000 |d 120700 |e 120000PW1082151173 |e 120700PW1082151173 |k 0/120000/ |k 1/120000/120700/ |p 2 | ||
| 998 | |g 1096352192 |a Lemke, Nele |m 1096352192:Lemke, Nele |d 850000 |d 851600 |e 850000PL1096352192 |e 851600PL1096352192 |k 0/850000/ |k 1/850000/851600/ |p 1 |x j | ||
| 999 | |a KXP-PPN1578444659 |e 3020534232 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"title":[{"title_sort":"Archives of gerontology and geriatrics","title":"Archives of gerontology and geriatrics"}],"pubHistory":["1.1982 -"],"part":{"volume":"70","text":"70(2017), Seite 169-179","extent":"11","year":"2017","pages":"169-179"},"note":["Gesehen am 14.10.2020"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Validity, test-retest reliability, sensitivity to change and feasibility of motor-cognitive dual task assessments in patients with dementiaArchives of gerontology and geriatrics","language":["eng"],"recId":"320639312","origin":[{"dateIssuedKey":"1982","publisher":"Elsevier Science","dateIssuedDisp":"1982-","publisherPlace":"Amsterdam [u.a.]"}],"id":{"zdb":["2024857-X"],"eki":["320639312"],"issn":["1872-6976"]},"physDesc":[{"extent":"Online-Ressource"}]}],"physDesc":[{"extent":"11 S."}],"name":{"displayForm":["Nele C. Lemke, Stefanie Wiloth, Christian Werner, Klaus Hauer"]},"id":{"doi":["10.1016/j.archger.2017.01.016"],"eki":["1578444659"]},"origin":[{"dateIssuedDisp":"30 January 2017","dateIssuedKey":"2017"}],"language":["eng"],"recId":"1578444659","type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Available online 30 January 2017","Gesehen am 09.08.2018"],"person":[{"roleDisplay":"VerfasserIn","display":"Lemke, Nele","role":"aut","family":"Lemke","given":"Nele"},{"family":"Wiloth","given":"Stefanie","roleDisplay":"VerfasserIn","display":"Wiloth, Stefanie","role":"aut"},{"display":"Werner, Christian","roleDisplay":"VerfasserIn","role":"aut","family":"Werner","given":"Christian"},{"role":"aut","display":"Hauer, Klaus","roleDisplay":"VerfasserIn","given":"Klaus","family":"Hauer"}],"title":[{"title_sort":"Validity, test-retest reliability, sensitivity to change and feasibility of motor-cognitive dual task assessments in patients with dementia","title":"Validity, test-retest reliability, sensitivity to change and feasibility of motor-cognitive dual task assessments in patients with dementia"}]} | ||
| SRT | |a LEMKENELEWVALIDITYTE3020 | ||