Balloon Dilatation of the Minor Duodenal Papilla Up to 4 mm is Safe in a Porcine Model

Objectives: Balloon dilatation of the minor duodenal papilla is a treatment option for symptomatic pancreas divisum. The histologic effects of balloon dilatation have not yet been evaluated. The aim of this study is to investigate the tolerated extent of dilatation of the minor papilla. Materials an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Müller, Philip C. (VerfasserIn) , Steinemann, Daniel (VerfasserIn) , Sauer, Peter (VerfasserIn) , Z’graggen, Kaspar (VerfasserIn) , Linke, Georg R. (VerfasserIn) , Müller, Beat P. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2017
In: Surgical laparoscopy, endoscopy & percutaneous techniques
Year: 2017, Jahrgang: 27, Heft: 4, Pages: e44-e47
ISSN:1534-4908
DOI:10.1097/SLE.0000000000000414
Online-Zugang:Verlag, Volltext: https://journals.lww.com/surgical-laparoscopy/Abstract/2017/08000/Balloon_Dilatation_of_the_Minor_Duodenal_Papilla.19.aspx
Verlag, Volltext: http://dx.doi.org/10.1097/SLE.0000000000000414
Volltext
Verfasserangaben:Philip C. Müller, Daniel C. Steinemann, Peter Sauer, Kaspar Z’graggen, Georg R. Linke, Beat P. Müller-Stich

MARC

LEADER 00000caa a2200000 c 4500
001 1578508428
003 DE-627
005 20240316100509.0
007 cr uuu---uuuuu
008 180813s2017 xx |||||o 00| ||eng c
024 7 |a 10.1097/SLE.0000000000000414  |2 doi 
035 |a (DE-627)1578508428 
035 |a (DE-576)508508428 
035 |a (DE-599)BSZ508508428 
035 |a (OCoLC)1341016827 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Müller, Philip C.  |e VerfasserIn  |0 (DE-588)1156545463  |0 (DE-627)1019350628  |0 (DE-576)502244194  |4 aut 
245 1 0 |a Balloon Dilatation of the Minor Duodenal Papilla Up to 4 mm is Safe in a Porcine Model  |c Philip C. Müller, Daniel C. Steinemann, Peter Sauer, Kaspar Z’graggen, Georg R. Linke, Beat P. Müller-Stich 
264 1 |c 2017 
300 |a 4 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 13.08.2018 
520 |a Objectives: Balloon dilatation of the minor duodenal papilla is a treatment option for symptomatic pancreas divisum. The histologic effects of balloon dilatation have not yet been evaluated. The aim of this study is to investigate the tolerated extent of dilatation of the minor papilla. Materials and Methods: A dilatation of the minor papilla was performed in freshly explanted pancreas of pigs using biliary balloon dilatators. Three organs were not dilated (control group), in each 8 organs a dilatation of 4, 6, and 8 mm, respectively, was performed. Tissue damage was assessed by microscopic evaluation. Ductal wall disruption and perforation as well as a semiquantitative inflammation score was described and compared. Results: Ductal wall disruption was increased by dilatation of 6 (5/8; P=0.019) and 8 mm (6/8; P=0.006) compared with 4 mm (1/8). Median inflammation score was 0 (0 to 0), 1 (0 to 2), and 1 (0 to 2) for dilatation of 4, 6, and 8 mm, respectively (4 vs. 6 mm, P=0.007; 4 vs. 8 mm, P=0.026). No perforation occurred in the 4 (0/8) and 6 mm (0/8) group, 1 perforation occurred in the 8 mm group (1/8). Conclusions: A dilatation of up to 4 mm seems to be safe. However, dilatation of the minor papilla from 4 mm onwards is increasingly associated with tissue damage. These findings should be considered in endoscopic procedures dilating the minor duodenal papilla. 
700 1 |a Steinemann, Daniel  |e VerfasserIn  |0 (DE-588)1164188038  |0 (DE-627)1028647298  |0 (DE-576)50842190X  |4 aut 
700 1 |a Sauer, Peter  |e VerfasserIn  |0 (DE-588)1045620602  |0 (DE-627)774668644  |0 (DE-576)399111301  |4 aut 
700 1 |a Z’graggen, Kaspar  |e VerfasserIn  |0 (DE-588)1084359405  |0 (DE-627)848798708  |0 (DE-576)456306285  |4 aut 
700 1 |a Linke, Georg R.  |d 1975-  |e VerfasserIn  |0 (DE-588)129150266  |0 (DE-627)390021326  |0 (DE-576)297510304  |4 aut 
700 1 |a Müller, Beat P.  |d 1971-  |e VerfasserIn  |0 (DE-588)14066209X  |0 (DE-627)70374819X  |0 (DE-576)317992287  |4 aut 
773 0 8 |i Enthalten in  |t Surgical laparoscopy, endoscopy & percutaneous techniques  |d Hagerstown, Md. : Lippincott Williams & Wilkins, 1999  |g 27(2017), 4, Seite e44-e47  |h Online-Ressource  |w (DE-627)328187518  |w (DE-600)2045171-4  |w (DE-576)094505810  |x 1534-4908  |7 nnas  |a Balloon Dilatation of the Minor Duodenal Papilla Up to 4 mm is Safe in a Porcine Model 
773 1 8 |g volume:27  |g year:2017  |g number:4  |g pages:e44-e47  |g extent:4  |a Balloon Dilatation of the Minor Duodenal Papilla Up to 4 mm is Safe in a Porcine Model 
856 4 0 |u https://journals.lww.com/surgical-laparoscopy/Abstract/2017/08000/Balloon_Dilatation_of_the_Minor_Duodenal_Papilla.19.aspx  |x Verlag  |3 Volltext 
856 4 0 |u http://dx.doi.org/10.1097/SLE.0000000000000414  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20180813 
993 |a Article 
994 |a 2017 
998 |g 14066209X  |a Müller, Beat P.  |m 14066209X:Müller, Beat P.  |d 910000  |d 910200  |e 910000PM14066209X  |e 910200PM14066209X  |k 0/910000/  |k 1/910000/910200/  |p 6  |y j 
998 |g 129150266  |a Linke, Georg R.  |m 129150266:Linke, Georg R.  |d 910000  |d 910200  |e 910000PL129150266  |e 910200PL129150266  |k 0/910000/  |k 1/910000/910200/  |p 5 
998 |g 1045620602  |a Sauer, Peter  |m 1045620602:Sauer, Peter  |d 910000  |d 910100  |e 910000PS1045620602  |e 910100PS1045620602  |k 0/910000/  |k 1/910000/910100/  |p 3 
998 |g 1164188038  |a Steinemann, Daniel  |m 1164188038:Steinemann, Daniel  |p 2 
998 |g 1156545463  |a Müller, Philip C.  |m 1156545463:Müller, Philip C.  |d 910000  |d 910200  |e 910000PM1156545463  |e 910200PM1156545463  |k 0/910000/  |k 1/910000/910200/  |p 1  |x j 
999 |a KXP-PPN1578508428  |e 3020702321 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1578508428"],"doi":["10.1097/SLE.0000000000000414"]},"name":{"displayForm":["Philip C. Müller, Daniel C. Steinemann, Peter Sauer, Kaspar Z’graggen, Georg R. Linke, Beat P. Müller-Stich"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"note":["Gesehen am 13.08.2018"],"title":[{"title":"Balloon Dilatation of the Minor Duodenal Papilla Up to 4 mm is Safe in a Porcine Model","title_sort":"Balloon Dilatation of the Minor Duodenal Papilla Up to 4 mm is Safe in a Porcine Model"}],"origin":[{"dateIssuedDisp":"2017","dateIssuedKey":"2017"}],"relHost":[{"origin":[{"publisher":"Lippincott Williams & Wilkins","dateIssuedKey":"1999","dateIssuedDisp":"1999-","publisherPlace":"Hagerstown, Md."}],"title":[{"title":"Surgical laparoscopy, endoscopy & percutaneous techniques","title_sort":"Surgical laparoscopy, endoscopy & percutaneous techniques"}],"note":["Gesehen am 06.06.2025","Fortsetzung der Druck-Ausgabe"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"recId":"328187518","physDesc":[{"extent":"Online-Ressource"}],"disp":"Balloon Dilatation of the Minor Duodenal Papilla Up to 4 mm is Safe in a Porcine ModelSurgical laparoscopy, endoscopy & percutaneous techniques","titleAlt":[{"title":"Surgical laparoscopy, endoscopy and percutaneous techniques"}],"pubHistory":["Volume 9, issue 2 (April 1999)-"],"part":{"issue":"4","text":"27(2017), 4, Seite e44-e47","extent":"4","pages":"e44-e47","volume":"27","year":"2017"},"id":{"zdb":["2045171-4"],"eki":["328187518"],"issn":["1534-4908"]}}],"person":[{"display":"Müller, Philip C.","family":"Müller","given":"Philip C.","role":"aut"},{"display":"Steinemann, Daniel","role":"aut","given":"Daniel","family":"Steinemann"},{"given":"Peter","role":"aut","family":"Sauer","display":"Sauer, Peter"},{"display":"Z’graggen, Kaspar","given":"Kaspar","role":"aut","family":"Z’graggen"},{"display":"Linke, Georg R.","family":"Linke","role":"aut","given":"Georg R."},{"given":"Beat P.","role":"aut","family":"Müller","display":"Müller, Beat P."}],"physDesc":[{"extent":"4 S."}],"recId":"1578508428"} 
SRT |a MUELLERPHIBALLOONDIL2017