Monitoring of electrical activity of the diaphragm shows failure of T-piece trial earlier than protocol-based parameters in prolonged weaning in non-communicative neurological patients

Background: The weaning target in tracheotomised patients is not extubation, but spontaneous breathing without the support of a ventilator. Overloading the respiratory pump during such spontaneous breathing trials is unfavorable, prolongs weaning time, and increases morbidity and mortality. The goal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Trapp, Oliver (VerfasserIn) , Fiedler-Kalenka, Mascha (VerfasserIn) , Kalenka, Armin (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 06 January 2017
In: Neurocritical care
Year: 2017, Jahrgang: 27, Heft: 1, Pages: 35-43
ISSN:1556-0961
DOI:10.1007/s12028-016-0360-9
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1007/s12028-016-0360-9
Verlag, Volltext: https://link.springer.com/article/10.1007/s12028-016-0360-9
Volltext
Verfasserangaben:Oliver Trapp, Mascha Fiedler, Michael Hartwich, Martin Schorl, Armin Kalenka

MARC

LEADER 00000caa a2200000 c 4500
001 1580081347
003 DE-627
005 20220814221110.0
007 cr uuu---uuuuu
008 180815s2017 xx |||||o 00| ||eng c
024 7 |a 10.1007/s12028-016-0360-9  |2 doi 
035 |a (DE-627)1580081347 
035 |a (DE-576)510081347 
035 |a (DE-599)BSZ510081347 
035 |a (OCoLC)1341016760 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Trapp, Oliver  |d 1966-  |e VerfasserIn  |0 (DE-588)1124109021  |0 (DE-627)877836965  |0 (DE-576)482313935  |4 aut 
245 1 0 |a Monitoring of electrical activity of the diaphragm shows failure of T-piece trial earlier than protocol-based parameters in prolonged weaning in non-communicative neurological patients  |c Oliver Trapp, Mascha Fiedler, Michael Hartwich, Martin Schorl, Armin Kalenka 
264 1 |c 06 January 2017 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.08.2018 
520 |a Background: The weaning target in tracheotomised patients is not extubation, but spontaneous breathing without the support of a ventilator. Overloading the respiratory pump during such spontaneous breathing trials is unfavorable, prolongs weaning time, and increases morbidity and mortality. The goal of this study was to evaluate the electrical activity of the diaphragm during a t-piece trial in non-communicative neurological patients and the comparison to clinical parameters of exhaustion. Methods: During multiple t-piece trials, the electrical activity of the diaphragm was obtained before, during and after the end of the trial. T-piece trials were grouped based on the reason for stopping the trial (exhaustion or allotted time period). Results: Twenty-nine tracheotomised patients in prolonged weaning (29 ± 22 days ventilated at the start of the study) were included in a prospective observational study. T-piece trials (n = 152; 5 ± 2 per patient) were grouped based on the reason for stopping the trial (n = 91 because of exhaustion; n = 61 because of the allotted time period). We found that the electrical activity of the diaphragm exhibits an earlier increase than protocol-based clinical parameters in patients who failed the trial due to exhaustion. The electrical activity of the diaphragm shows no relevant difference during the t-piece trial in patients in whom the trial was stopped due to the allotted time period per protocol. Conclusions: Monitoring the electrical activity of the diaphragm in non-communicative neurological patients in prolonged weaning allows earlier detection of exhaustion than protocol-based parameters. 
700 1 |a Fiedler-Kalenka, Mascha  |d 1979-  |e VerfasserIn  |0 (DE-588)1018788603  |0 (DE-627)683425951  |0 (DE-576)356370283  |4 aut 
700 1 |a Kalenka, Armin  |d 1969-2025  |e VerfasserIn  |0 (DE-588)120095548  |0 (DE-627)080443192  |0 (DE-576)292038798  |4 aut 
773 0 8 |i Enthalten in  |t Neurocritical care  |d New York, NY : Springer, 2004  |g 27(2017), 1, Seite 35-43  |h Online-Ressource  |w (DE-627)478509855  |w (DE-600)2176033-0  |w (DE-576)306831910  |x 1556-0961  |7 nnas  |a Monitoring of electrical activity of the diaphragm shows failure of T-piece trial earlier than protocol-based parameters in prolonged weaning in non-communicative neurological patients 
773 1 8 |g volume:27  |g year:2017  |g number:1  |g pages:35-43  |g extent:9  |a Monitoring of electrical activity of the diaphragm shows failure of T-piece trial earlier than protocol-based parameters in prolonged weaning in non-communicative neurological patients 
856 4 0 |u http://dx.doi.org/10.1007/s12028-016-0360-9  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://link.springer.com/article/10.1007/s12028-016-0360-9  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180815 
993 |a Article 
994 |a 2017 
998 |g 120095548  |a Kalenka, Armin  |m 120095548:Kalenka, Armin  |d 60000  |e 60000PK120095548  |k 0/60000/  |p 5  |y j 
998 |g 1018788603  |a Fiedler-Kalenka, Mascha  |m 1018788603:Fiedler-Kalenka, Mascha  |d 60000  |d 61600  |e 60000PF1018788603  |e 61600PF1018788603  |k 0/60000/  |k 1/60000/61600/  |p 2 
999 |a KXP-PPN1580081347  |e 3022418604 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"title":[{"title_sort":"Monitoring of electrical activity of the diaphragm shows failure of T-piece trial earlier than protocol-based parameters in prolonged weaning in non-communicative neurological patients","title":"Monitoring of electrical activity of the diaphragm shows failure of T-piece trial earlier than protocol-based parameters in prolonged weaning in non-communicative neurological patients"}],"person":[{"role":"aut","display":"Trapp, Oliver","given":"Oliver","family":"Trapp"},{"family":"Fiedler-Kalenka","given":"Mascha","display":"Fiedler-Kalenka, Mascha","role":"aut"},{"given":"Armin","display":"Kalenka, Armin","family":"Kalenka","role":"aut"}],"recId":"1580081347","name":{"displayForm":["Oliver Trapp, Mascha Fiedler, Michael Hartwich, Martin Schorl, Armin Kalenka"]},"origin":[{"dateIssuedDisp":"06 January 2017","dateIssuedKey":"2017"}],"relHost":[{"name":{"displayForm":["Neurocritical Care Society"]},"origin":[{"publisher":"Springer ; Humana Press","dateIssuedDisp":"2004-","dateIssuedKey":"2004","publisherPlace":"New York, NY ; Totowa, NJ"}],"title":[{"title":"Neurocritical care","title_sort":"Neurocritical care"}],"id":{"eki":["478509855"],"issn":["1556-0961"],"zdb":["2176033-0"]},"part":{"volume":"27","text":"27(2017), 1, Seite 35-43","year":"2017","pages":"35-43","extent":"9","issue":"1"},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 11.09.14"],"disp":"Monitoring of electrical activity of the diaphragm shows failure of T-piece trial earlier than protocol-based parameters in prolonged weaning in non-communicative neurological patientsNeurocritical care","recId":"478509855","language":["eng"],"pubHistory":["1.2004 -"],"type":{"bibl":"periodical","media":"Online-Ressource"}}],"note":["Gesehen am 15.08.2018"],"physDesc":[{"extent":"9 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1580081347"],"doi":["10.1007/s12028-016-0360-9"]}} 
SRT |a TRAPPOLIVEMONITORING0620