Clinical evaluation of an extended depth of focus intraocular lens with the Salzburg reading desk

BACKGROUND: Clinical evaluation of an extended depth of focus (EDOF) intraocular lens (IOL) regarding visual performance at various distances, reading performance on an electronic reading desk, and depth of focus on the defocus curve. METHODS: In this prospective study, 30 eyes of 15 patients who re...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Attia, Mary (VerfasserIn) , Auffarth, Gerd U. (VerfasserIn) , Kretz, Florian Tobias Alwin (VerfasserIn) , Tandogan, Tamer (VerfasserIn) , Rabsilber, Tanja Marina (VerfasserIn) , Holzer, Mike P. (VerfasserIn) , Khoramnia, Ramin (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: October 10, 2017
In: Journal of refractive surgery
Year: 2017, Jahrgang: 33, Heft: 10, Pages: 664-669
ISSN:1938-2391
DOI:10.3928/1081597X-20170621-08
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.3928/1081597X-20170621-08
Volltext
Verfasserangaben:Mary S.A. Attia, Gerd U. Auffarth, Florian T.A. Kretz, Tamer Tandogan, Tanja M. Rabsilber, Mike P. Holzer, Ramin Khoramnia

MARC

LEADER 00000caa a2200000 c 4500
001 1580243428
003 DE-627
005 20220814225129.0
007 cr uuu---uuuuu
008 180821s2017 xx |||||o 00| ||eng c
024 7 |a 10.3928/1081597X-20170621-08  |2 doi 
035 |a (DE-627)1580243428 
035 |a (DE-576)510243428 
035 |a (DE-599)BSZ510243428 
035 |a (OCoLC)1341017126 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Attia, Mary  |d 1987-  |e VerfasserIn  |0 (DE-588)1078750378  |0 (DE-627)839330189  |0 (DE-576)451670086  |4 aut 
245 1 0 |a Clinical evaluation of an extended depth of focus intraocular lens with the Salzburg reading desk  |c Mary S.A. Attia, Gerd U. Auffarth, Florian T.A. Kretz, Tamer Tandogan, Tanja M. Rabsilber, Mike P. Holzer, Ramin Khoramnia 
264 1 |c October 10, 2017 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 21.08.2018 
520 |a BACKGROUND: Clinical evaluation of an extended depth of focus (EDOF) intraocular lens (IOL) regarding visual performance at various distances, reading performance on an electronic reading desk, and depth of focus on the defocus curve. METHODS: In this prospective study, 30 eyes of 15 patients who received the Tecnis Symfony IOL (Abbott Medical Optics, Inc., Santa Ana, CA) were examined 3.60 ± 1.54 months postoperatively. Uncorrected and corrected distance (UDVA and CDVA), uncorrected and distance-corrected intermediate (UIVA and DCIVA), and uncorrected and distance-corrected near (UNVA and DCNVA) visual acuity were determined. The defocus curve was performed with distance correction. Furthermore, the reading acuity at the preferred near and intermediate distances was measured with consideration of the reading distance, speed, and print size. A subjective questionnaire was also administered. RESULTS: Results showed a median UDVA of 0.03 logMAR or 20/21.43 Snellen (range: 0.44 to -0.18 logMAR or 20/55.08 to 20/13.21 Snellen), UNVA of 0.20 logMAR or 20/31.70 Snellen (range: 0.46 to 0.00 logMAR or 20/57.68 to 20/20 Snellen), and UIVA of -0.03 logMAR or 20/18.67 Snellen (range: 0.14 to -0.18 logMAR or 20/27.61 to 20/13.21 Snellen). The improved performance at intermediate distance was confirmed by an uncorrected reading acuity of 0.09 logMAR or 20/24.61 Snellen (range: 0.36 to 0.00 logMAR or 20/45.82 to 20/20.00 Snellen) at a preferred intermediate distance of 64.10 cm (range: 52.0 to 75.0 cm). The defocus curve showed an extended range of visual acuity of 0.10 logMAR or better between 1.00 and -1.50 diopters. CONCLUSIONS: The EDOF IOL design provided a wide range of improved visual and reading function between far and intermediate distances and also improved near visual acuity. Patients reported a high rate of satisfaction and spectacle independence at the various distances. [J Refract Surg. 2017;33(10):664-669.]. 
650 4 |a Aged 
650 4 |a Cataract 
650 4 |a Female 
650 4 |a Humans 
650 4 |a Lenses, Intraocular 
650 4 |a Male 
650 4 |a Middle Aged 
650 4 |a Postoperative Period 
650 4 |a Prospective Studies 
650 4 |a Prosthesis Design 
650 4 |a Pseudophakia 
650 4 |a Reading 
650 4 |a Refraction, Ocular 
650 4 |a Surveys and Questionnaires 
650 4 |a Vision Tests 
650 4 |a Vision, Binocular 
650 4 |a Visual Acuity 
700 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
700 1 |a Kretz, Florian Tobias Alwin  |d 1982-  |e VerfasserIn  |0 (DE-588)1048598136  |0 (DE-627)780696042  |0 (DE-576)402441044  |4 aut 
700 1 |a Tandogan, Tamer  |d 1965-  |e VerfasserIn  |0 (DE-588)129861812  |0 (DE-627)48236419X  |0 (DE-576)297874578  |4 aut 
700 1 |a Rabsilber, Tanja Marina  |d 1977-  |e VerfasserIn  |0 (DE-588)128743271  |0 (DE-627)378689541  |0 (DE-576)297309609  |4 aut 
700 1 |a Holzer, Mike P.  |d 1973-  |e VerfasserIn  |0 (DE-588)122217527  |0 (DE-627)705818640  |0 (DE-576)293157812  |4 aut 
700 1 |a Khoramnia, Ramin  |d 1980-  |e VerfasserIn  |0 (DE-588)132573954  |0 (DE-627)523957173  |0 (DE-576)299234355  |4 aut 
773 0 8 |i Enthalten in  |t Journal of refractive surgery  |d Thorofare, NJ : SLACK Inc., 1996  |g 33(2017), 10, Seite 664-669  |h Online-Ressource  |w (DE-627)333811267  |w (DE-600)2056758-3  |w (DE-576)433787627  |x 1938-2391  |7 nnas  |a Clinical evaluation of an extended depth of focus intraocular lens with the Salzburg reading desk 
773 1 8 |g volume:33  |g year:2017  |g number:10  |g pages:664-669  |g extent:6  |a Clinical evaluation of an extended depth of focus intraocular lens with the Salzburg reading desk 
856 4 0 |u http://dx.doi.org/10.3928/1081597X-20170621-08  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20180821 
993 |a Article 
994 |a 2017 
998 |g 132573954  |a Khoramnia, Ramin  |m 132573954:Khoramnia, Ramin  |d 910000  |d 910900  |e 910000PK132573954  |e 910900PK132573954  |k 0/910000/  |k 1/910000/910900/  |p 7  |y j 
998 |g 122217527  |a Holzer, Mike P.  |m 122217527:Holzer, Mike P.  |d 910000  |d 910900  |e 910000PH122217527  |e 910900PH122217527  |k 0/910000/  |k 1/910000/910900/  |p 6 
998 |g 128743271  |a Rabsilber, Tanja Marina  |m 128743271:Rabsilber, Tanja Marina  |d 910000  |d 910900  |e 910000PR128743271  |e 910900PR128743271  |k 0/910000/  |k 1/910000/910900/  |p 5 
998 |g 129861812  |a Tandogan, Tamer  |m 129861812:Tandogan, Tamer  |d 910000  |d 910900  |e 910000PT129861812  |e 910900PT129861812  |k 0/910000/  |k 1/910000/910900/  |p 4 
998 |g 1048598136  |a Kretz, Florian Tobias Alwin  |m 1048598136:Kretz, Florian Tobias Alwin  |d 910000  |d 910900  |e 910000PK1048598136  |e 910900PK1048598136  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 2 
998 |g 1078750378  |a Attia, Mary  |m 1078750378:Attia, Mary  |d 910000  |d 910900  |e 910000PA1078750378  |e 910900PA1078750378  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1580243428  |e 3022880499 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"physDesc":[{"extent":"6 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"display":"Attia, Mary","given":"Mary","role":"aut","family":"Attia"},{"display":"Auffarth, Gerd U.","family":"Auffarth","role":"aut","given":"Gerd U."},{"family":"Kretz","role":"aut","given":"Florian Tobias Alwin","display":"Kretz, Florian Tobias Alwin"},{"display":"Tandogan, Tamer","role":"aut","given":"Tamer","family":"Tandogan"},{"display":"Rabsilber, Tanja Marina","family":"Rabsilber","role":"aut","given":"Tanja Marina"},{"given":"Mike P.","role":"aut","family":"Holzer","display":"Holzer, Mike P."},{"display":"Khoramnia, Ramin","family":"Khoramnia","given":"Ramin","role":"aut"}],"title":[{"title":"Clinical evaluation of an extended depth of focus intraocular lens with the Salzburg reading desk","title_sort":"Clinical evaluation of an extended depth of focus intraocular lens with the Salzburg reading desk"}],"name":{"displayForm":["Mary S.A. Attia, Gerd U. Auffarth, Florian T.A. Kretz, Tamer Tandogan, Tanja M. Rabsilber, Mike P. Holzer, Ramin Khoramnia"]},"recId":"1580243428","id":{"doi":["10.3928/1081597X-20170621-08"],"eki":["1580243428"]},"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"October 10, 2017"}],"note":["Gesehen am 21.08.2018"],"relHost":[{"id":{"zdb":["2056758-3"],"issn":["1938-2391"],"eki":["333811267"]},"origin":[{"publisherPlace":"Thorofare, NJ","publisher":"SLACK Inc.","dateIssuedKey":"1996","dateIssuedDisp":"1996-"}],"part":{"year":"2017","issue":"10","extent":"6","text":"33(2017), 10, Seite 664-669","pages":"664-669","volume":"33"},"recId":"333811267","disp":"Clinical evaluation of an extended depth of focus intraocular lens with the Salzburg reading deskJournal of refractive surgery","title":[{"title_sort":"Journal of refractive surgery","title":"Journal of refractive surgery","subtitle":"the official publication of the International Society of Refractive Surgery"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 26.09.24"],"language":["eng"],"pubHistory":["Nachgewiesen 12.1996 -"],"physDesc":[{"extent":"Online-Ressource"}]}]} 
SRT |a ATTIAMARYACLINICALEV1020