Downfield-NOE-suppressed amide-CEST-MRI at 7 Tesla provides a unique contrast in human glioblastoma

Purpose The chemical exchange saturation transfer (CEST) effect observed in brain tissue in vivo at the frequency offset 3.5 ppm downfield of water was assigned to amide protons of the protein backbone. Obeying a base-catalyzed exchange process such an amide-CEST effect would correlate with intracel...

Full description

Saved in:
Bibliographic Details
Main Authors: Zaiss, Moritz (Author) , Paech, Daniel (Author) , Burth, Sina (Author) , Vollmuth, Philipp (Author) , Wick, Wolfgang (Author) , Bendszus, Martin (Author) , Schlemmer, Heinz-Peter (Author) , Ladd, Mark E. (Author) , Bachert, Peter (Author) , Radbruch, Alexander (Author)
Format: Article (Journal)
Language:English
Published: 2017
In: Magnetic resonance in medicine
Year: 2016, Volume: 77, Issue: 1, Pages: 196-208
ISSN:1522-2594
DOI:10.1002/mrm.26100
Online Access:Verlag, Volltext: http://dx.doi.org/10.1002/mrm.26100
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.26100
Get full text
Author Notes:Moritz Zaiss, Johannes Windschuh, Steffen Goerke, Daniel Paech, Jan-Eric Meissner, Sina Burth, Philipp Kickingereder, Wolfgang Wick, Martin Bendszus, Heinz-Peter Schlemmer, Mark E. Ladd, Peter Bachert, and Alexander Radbruch

MARC

LEADER 00000caa a2200000 c 4500
001 1580272835
003 DE-627
005 20230427065652.0
007 cr uuu---uuuuu
008 180822r20172016xx |||||o 00| ||eng c
024 7 |a 10.1002/mrm.26100  |2 doi 
035 |a (DE-627)1580272835 
035 |a (DE-576)510272835 
035 |a (DE-599)BSZ510272835 
035 |a (OCoLC)1341017099 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Zaiss, Moritz  |e VerfasserIn  |0 (DE-588)1047655659  |0 (DE-627)778741095  |0 (DE-576)330036947  |4 aut 
245 1 0 |a Downfield-NOE-suppressed amide-CEST-MRI at 7 Tesla provides a unique contrast in human glioblastoma  |c Moritz Zaiss, Johannes Windschuh, Steffen Goerke, Daniel Paech, Jan-Eric Meissner, Sina Burth, Philipp Kickingereder, Wolfgang Wick, Martin Bendszus, Heinz-Peter Schlemmer, Mark E. Ladd, Peter Bachert, and Alexander Radbruch 
264 1 |c 2017 
300 |a 13 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online 27 January 2016 
500 |a Gesehen am 22.08.2018 
520 |a Purpose The chemical exchange saturation transfer (CEST) effect observed in brain tissue in vivo at the frequency offset 3.5 ppm downfield of water was assigned to amide protons of the protein backbone. Obeying a base-catalyzed exchange process such an amide-CEST effect would correlate with intracellular pH and protein concentration, correlations that are highly interesting for cancer diagnosis. However, recent experiments suggested that, besides the known aliphatic relayed-nuclear Overhauser effect (rNOE) upfield of water, an additional downfield rNOE is apparent in vivo resonating as well around +3.5 ppm. In this study, we present further evidence for the underlying downfield-rNOE signal, and we propose a first method that suppresses the downfield-rNOE contribution to the amide-CEST contrast. Thus, an isolated amide-CEST effect depending mainly on amide proton concentration and pH is generated. Methods The isolation of the exchange mediated amide proton effect was investigated in protein model-solutions and tissue lysates and successfully applied to in vivo CEST images of 11 glioblastoma patients. Results Comparison with gadolinium contrast enhancing longitudinal relaxation time-weighted images revealed that the downfield-rNOE-suppressed amide-CEST contrast forms a unique contrast that delineates tumor regions and show remarkable overlap with the gadolinium contrast enhancement. Conclusion Thus, suppression of the downfield rNOE contribution might be the important step to yield the amide proton CEST contrast originally aimed at. Magn Reson Med 77:196-208, 2017. © 2016 Wiley Periodicals, Inc. 
534 |c 2016 
650 4 |a 7T 
650 4 |a aliphatic rNOE 
650 4 |a AREX 
650 4 |a aromatic rNOE 
650 4 |a brain tumor 
650 4 |a CEST 
650 4 |a glioblastoma 
650 4 |a relaxation compensation 
650 4 |a relaxation-compensated CEST 
650 4 |a spillover correction 
650 4 |a ultra-high field 
700 1 |a Paech, Daniel  |d 1986-  |e VerfasserIn  |0 (DE-588)1080278214  |0 (DE-627)844124893  |0 (DE-576)453464742  |4 aut 
700 1 |a Burth, Sina  |e VerfasserIn  |0 (DE-588)1098194896  |0 (DE-627)857484885  |0 (DE-576)469019263  |4 aut 
700 1 |a Vollmuth, Philipp  |d 1987-  |e VerfasserIn  |0 (DE-588)1043270086  |0 (DE-627)771319177  |0 (DE-576)394600738  |4 aut 
700 1 |a Wick, Wolfgang  |d 1970-  |e VerfasserIn  |0 (DE-588)120297736  |0 (DE-627)080586929  |0 (DE-576)186221320  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Schlemmer, Heinz-Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)1025559967  |0 (DE-627)722927142  |0 (DE-576)17334805X  |4 aut 
700 1 |a Ladd, Mark E.  |e VerfasserIn  |0 (DE-588)108120964X  |0 (DE-627)845690507  |0 (DE-576)454039999  |4 aut 
700 1 |a Bachert, Peter  |e VerfasserIn  |0 (DE-588)1103529633  |0 (DE-627)861285824  |0 (DE-576)251203298  |4 aut 
700 1 |a Radbruch, Alexander  |d 1977-  |e VerfasserIn  |0 (DE-588)1022344501  |0 (DE-627)716953951  |0 (DE-576)362851166  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in medicine  |d New York, NY [u.a.] : Wiley-Liss, 1984  |g 77(2017), 1, Seite 196-208  |h Online-Ressource  |w (DE-627)303257040  |w (DE-600)1493786-4  |w (DE-576)096290455  |x 1522-2594  |7 nnas  |a Downfield-NOE-suppressed amide-CEST-MRI at 7 Tesla provides a unique contrast in human glioblastoma 
773 1 8 |g volume:77  |g year:2017  |g number:1  |g pages:196-208  |g extent:13  |a Downfield-NOE-suppressed amide-CEST-MRI at 7 Tesla provides a unique contrast in human glioblastoma 
856 4 0 |u http://dx.doi.org/10.1002/mrm.26100  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.26100  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180822 
993 |a Article 
994 |a 2017 
998 |g 1022344501  |a Radbruch, Alexander  |m 1022344501:Radbruch, Alexander  |d 910000  |d 911100  |e 910000PR1022344501  |e 911100PR1022344501  |k 0/910000/  |k 1/910000/911100/  |p 13  |y j 
998 |g 1103529633  |a Bachert, Peter  |m 1103529633:Bachert, Peter  |d 130000  |e 130000PB1103529633  |k 0/130000/  |p 12 
998 |g 108120964X  |a Ladd, Mark E.  |m 108120964X:Ladd, Mark E.  |d 50000  |e 50000PL108120964X  |k 0/50000/  |p 11 
998 |g 1025559967  |a Schlemmer, Heinz-Peter  |m 1025559967:Schlemmer, Heinz-Peter  |d 50000  |e 50000PS1025559967  |k 0/50000/  |p 10 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 9 
998 |g 120297736  |a Wick, Wolfgang  |m 120297736:Wick, Wolfgang  |d 910000  |d 911100  |e 910000PW120297736  |e 911100PW120297736  |k 0/910000/  |k 1/910000/911100/  |p 8 
998 |g 1043270086  |a Vollmuth, Philipp  |m 1043270086:Vollmuth, Philipp  |d 910000  |d 911100  |e 910000PV1043270086  |e 911100PV1043270086  |k 0/910000/  |k 1/910000/911100/  |p 7 
998 |g 1098194896  |a Burth, Sina  |m 1098194896:Burth, Sina  |d 910000  |d 911100  |e 910000PB1098194896  |e 911100PB1098194896  |k 0/910000/  |k 1/910000/911100/  |p 6 
998 |g 1080278214  |a Paech, Daniel  |m 1080278214:Paech, Daniel  |d 50000  |e 50000PP1080278214  |k 0/50000/  |p 4 
999 |a KXP-PPN1580272835  |e 3022923368 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1580272835"],"doi":["10.1002/mrm.26100"]},"name":{"displayForm":["Moritz Zaiss, Johannes Windschuh, Steffen Goerke, Daniel Paech, Jan-Eric Meissner, Sina Burth, Philipp Kickingereder, Wolfgang Wick, Martin Bendszus, Heinz-Peter Schlemmer, Mark E. Ladd, Peter Bachert, and Alexander Radbruch"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Published online 27 January 2016","Gesehen am 22.08.2018"],"title":[{"title":"Downfield-NOE-suppressed amide-CEST-MRI at 7 Tesla provides a unique contrast in human glioblastoma","title_sort":"Downfield-NOE-suppressed amide-CEST-MRI at 7 Tesla provides a unique contrast in human glioblastoma"}],"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"2017"}],"relHost":[{"part":{"text":"77(2017), 1, Seite 196-208","extent":"13","issue":"1","pages":"196-208","volume":"77","year":"2017"},"id":{"doi":["10.1002/(ISSN)1522-2594"],"zdb":["1493786-4"],"eki":["303257040"],"issn":["1522-2594"]},"titleAlt":[{"title":"MRM"}],"pubHistory":["1.1984 -"],"disp":"Downfield-NOE-suppressed amide-CEST-MRI at 7 Tesla provides a unique contrast in human glioblastomaMagnetic resonance in medicine","physDesc":[{"extent":"Online-Ressource"}],"recId":"303257040","note":["Gesehen am 28.02.08"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"subtitle":"MRM ; an official journal of the International Society for Magnetic Resonance in Medicine","title_sort":"Magnetic resonance in medicine","title":"Magnetic resonance in medicine"}],"origin":[{"dateIssuedKey":"1984","publisherPlace":"New York, NY [u.a.]","dateIssuedDisp":"1984-","publisher":"Wiley-Liss"}]}],"person":[{"display":"Zaiss, Moritz","given":"Moritz","role":"aut","family":"Zaiss"},{"role":"aut","given":"Daniel","family":"Paech","display":"Paech, Daniel"},{"given":"Sina","role":"aut","family":"Burth","display":"Burth, Sina"},{"display":"Vollmuth, Philipp","family":"Vollmuth","given":"Philipp","role":"aut"},{"family":"Wick","given":"Wolfgang","role":"aut","display":"Wick, Wolfgang"},{"role":"aut","given":"Martin","family":"Bendszus","display":"Bendszus, Martin"},{"display":"Schlemmer, Heinz-Peter","family":"Schlemmer","given":"Heinz-Peter","role":"aut"},{"display":"Ladd, Mark E.","family":"Ladd","given":"Mark E.","role":"aut"},{"display":"Bachert, Peter","family":"Bachert","role":"aut","given":"Peter"},{"display":"Radbruch, Alexander","family":"Radbruch","role":"aut","given":"Alexander"}],"physDesc":[{"extent":"13 S."}],"recId":"1580272835"} 
SRT |a ZAISSMORITDOWNFIELDN2017