What to do when you question cardiac troponin values

High-sensitivity cardiac troponin assays enable cardiac troponin measurement with a high degree of analytical sensitivity and a low level of analytical imprecision at the low measuring range. One of the most important advantages of these new assays is that they allow novel, more rapid approaches for...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mair, Johannes (VerfasserIn) , Giannitsis, Evangelos (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2018
In: European heart journal - acute cardiovascular care
Year: 2017, Jahrgang: 7, Heft: 6, Pages: 577-586
ISSN:2048-8734
DOI:10.1177/2048872617708973
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1177/2048872617708973
Verlag, Volltext: https://doi.org/10.1177/2048872617708973
Volltext
Verfasserangaben:Johannes Mair, Bertil Lindahl, Christian Müller, Evangelos Giannitsis, Kurt Huber, Martin Möckel, Mario Plebani, Kristian Thygesen and Allan S Jaffe

MARC

LEADER 00000caa a2200000 c 4500
001 1580298435
003 DE-627
005 20220814230515.0
007 cr uuu---uuuuu
008 180822r20182017xx |||||o 00| ||eng c
024 7 |a 10.1177/2048872617708973  |2 doi 
035 |a (DE-627)1580298435 
035 |a (DE-576)510298435 
035 |a (DE-599)BSZ510298435 
035 |a (OCoLC)1341017329 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mair, Johannes  |e VerfasserIn  |0 (DE-588)1165184982  |0 (DE-627)1029345236  |0 (DE-576)510295614  |4 aut 
245 1 0 |a What to do when you question cardiac troponin values  |c Johannes Mair, Bertil Lindahl, Christian Müller, Evangelos Giannitsis, Kurt Huber, Martin Möckel, Mario Plebani, Kristian Thygesen and Allan S Jaffe 
264 1 |c 2018 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published May 9, 2017 
500 |a Gesehen am 22.08.2018 
520 |a High-sensitivity cardiac troponin assays enable cardiac troponin measurement with a high degree of analytical sensitivity and a low level of analytical imprecision at the low measuring range. One of the most important advantages of these new assays is that they allow novel, more rapid approaches for ruling in or ruling out acute myocardial infarctions. The increase in the early diagnostic sensitivity of high-sensitivity cardiac troponin assays comes at the cost of a reduced acute myocardial infarction specificity of the biomarker, because more patients with other causes of acute or chronic myocardial injury without overt myocardial ischaemia are detected than with previous cardiac troponin assays. Increased troponin concentrations that do not fit with the clinical presentation are seen in the daily routine, mainly as a result of a variety of pathologies, and if tested in the same sample, even discrepancies between high-sensitivity cardiac troponin I and troponin T test results may sometimes be found as well. In addition, analytically false-positive test results occasionally may occur since no assay is perfect. In this review, we summarise the biochemical, pathophysiological and analytical background of the work-up for such a clinical setting. 
534 |c 2017 
700 1 |a Giannitsis, Evangelos  |e VerfasserIn  |0 (DE-588)113336241  |0 (DE-627)577184091  |0 (DE-576)289759579  |4 aut 
773 0 8 |i Enthalten in  |t European heart journal - acute cardiovascular care  |d Oxford : Oxford University Press, 2012  |g 7(2018), 6, Seite 577-586  |h Online-Ressource  |w (DE-627)718660390  |w (DE-600)2663340-1  |w (DE-576)39669909X  |x 2048-8734  |7 nnas  |a What to do when you question cardiac troponin values 
773 1 8 |g volume:7  |g year:2018  |g number:6  |g pages:577-586  |g extent:10  |a What to do when you question cardiac troponin values 
856 4 0 |u http://dx.doi.org/10.1177/2048872617708973  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://doi.org/10.1177/2048872617708973  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180822 
993 |a Article 
994 |a 2018 
998 |g 113336241  |a Giannitsis, Evangelos  |m 113336241:Giannitsis, Evangelos  |d 910000  |d 910100  |e 910000PG113336241  |e 910100PG113336241  |k 0/910000/  |k 1/910000/910100/  |p 4 
999 |a KXP-PPN1580298435  |e 3022962541 
BIB |a Y 
SER |a journal 
JSO |a {"note":["First published May 9, 2017","Gesehen am 22.08.2018"],"recId":"1580298435","person":[{"given":"Johannes","display":"Mair, Johannes","family":"Mair","role":"aut"},{"display":"Giannitsis, Evangelos","given":"Evangelos","family":"Giannitsis","role":"aut"}],"name":{"displayForm":["Johannes Mair, Bertil Lindahl, Christian Müller, Evangelos Giannitsis, Kurt Huber, Martin Möckel, Mario Plebani, Kristian Thygesen and Allan S Jaffe"]},"language":["eng"],"origin":[{"dateIssuedDisp":"2018","dateIssuedKey":"2018"}],"relHost":[{"part":{"pages":"577-586","extent":"10","issue":"6","text":"7(2018), 6, Seite 577-586","volume":"7","year":"2018"},"language":["eng"],"note":["Gesehen am 15.02.2023"],"pubHistory":["1.2012 -"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"What to do when you question cardiac troponin valuesEuropean heart journal - acute cardiovascular care","titleAlt":[{"title":"Acute Cardiovascular Care"}],"name":{"displayForm":["European Society of Cardiology"]},"recId":"718660390","physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["2048-8734"],"eki":["718660390"],"zdb":["2663340-1"]},"title":[{"title_sort":"European heart journal - acute cardiovascular care","title":"European heart journal - acute cardiovascular care"}],"origin":[{"dateIssuedKey":"2012","publisherPlace":"Oxford ; London","publisher":"Oxford University Press ; Sage Publishing","dateIssuedDisp":"2012-"}]}],"physDesc":[{"extent":"10 S."}],"id":{"doi":["10.1177/2048872617708973"],"eki":["1580298435"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"What to do when you question cardiac troponin values","title":"What to do when you question cardiac troponin values"}]} 
SRT |a MAIRJOHANNWHATTODOWH2018