Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery

PURPOSE: To compare the clinical performance and safety of 2 ophthalmic viscosurgical devices (OVDs)-Twinvisc (OVD 1) and Duovisc (OVD 2)-in cataract surgery. SETTING: European multicenter study. DESIGN: Prospective randomized controlled study. METHODS: Patients with cataract had phacoemulsification...

Full description

Saved in:
Bibliographic Details
Main Authors: Auffarth, Gerd U. (Author) , Auerbach, Florian Niklas (Author) , Rabsilber, Tanja Marina (Author) , Holzer, Mike P. (Author)
Format: Article (Journal)
Language:English
Published: 2017
In: Journal of cataract and refractive surgery
Year: 2017, Volume: 43, Issue: 1, Pages: 87-94
ISSN:1873-4502
DOI:10.1016/j.jcrs.2016.10.025
Online Access:Verlag, Volltext: http://dx.doi.org/10.1016/j.jcrs.2016.10.025
Get full text
Author Notes:Gerd U. Auffarth, Florian N. Auerbach, Tanja Rabsilber, José A. Gegúndez, Ricardo Cuiña, Yves Renard, Paolo Vinciguerra, Fabrizio Camesasca, Francoise Van Cauwenberge, Thierry Amzallag, Gysbert Van Setten, Mike P. Holzer
Description
Summary:PURPOSE: To compare the clinical performance and safety of 2 ophthalmic viscosurgical devices (OVDs)-Twinvisc (OVD 1) and Duovisc (OVD 2)-in cataract surgery. SETTING: European multicenter study. DESIGN: Prospective randomized controlled study. METHODS: Patients with cataract had phacoemulsification and intraocular lens implantation in 1 eye. They were randomly assigned to receive OVD 1 or OVD 2. Preoperative and postoperative examinations over 3 months included mean intraocular pressure (IOP), incidence of IOP peaks (≥30 mm Hg and ≥24 mm Hg), endothelial cell count (ECC), corneal thickness, and intraocular inflammation. A subjective evaluation of the OVDs was performed. RESULTS: The study comprised 220 patients. The incidence of IOP peaks and the mean IOP were not statistically significantly different between the 2 groups at any of the follow-up visits. At 6 hours, the incidence of IOP spikes 30 mm Hg or higher was 6.5% and 7.2% in the OVD 1 and the OVD 2 groups, respectively (P = .846). For the IOP spikes 24 mm Hg or higher, the incidence was 16.8% and 25.2%, respectively (P = .128). Three months postoperatively there was no statistically significant difference in ECC and pachymetry between the 2 groups. Mild inflammation was noticed up to 7 days postoperatively after which it resolved in both groups. Subjectively, the OVD 2 was easier to use, whereas the OVD 1 had better cohesive and dispersive properties. CONCLUSIONS: Both OVDs have similar performance and safety profiles in phacoemulsification cataract surgery. No clinically relevant differences were found between the 2 devices regarding transient IOP spikes, mean IOP, corneal endothelium injury, or inflammation.