Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery

PURPOSE: To compare the clinical performance and safety of 2 ophthalmic viscosurgical devices (OVDs)-Twinvisc (OVD 1) and Duovisc (OVD 2)-in cataract surgery. SETTING: European multicenter study. DESIGN: Prospective randomized controlled study. METHODS: Patients with cataract had phacoemulsification...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Auffarth, Gerd U. (VerfasserIn) , Auerbach, Florian Niklas (VerfasserIn) , Rabsilber, Tanja Marina (VerfasserIn) , Holzer, Mike P. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2017
In: Journal of cataract and refractive surgery
Year: 2017, Jahrgang: 43, Heft: 1, Pages: 87-94
ISSN:1873-4502
DOI:10.1016/j.jcrs.2016.10.025
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.jcrs.2016.10.025
Volltext
Verfasserangaben:Gerd U. Auffarth, Florian N. Auerbach, Tanja Rabsilber, José A. Gegúndez, Ricardo Cuiña, Yves Renard, Paolo Vinciguerra, Fabrizio Camesasca, Francoise Van Cauwenberge, Thierry Amzallag, Gysbert Van Setten, Mike P. Holzer

MARC

LEADER 00000caa a2200000 c 4500
001 1580340091
003 DE-627
005 20240316100513.0
007 cr uuu---uuuuu
008 180823s2017 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jcrs.2016.10.025  |2 doi 
035 |a (DE-627)1580340091 
035 |a (DE-576)510340091 
035 |a (DE-599)BSZ510340091 
035 |a (OCoLC)1341017590 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
245 1 0 |a Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery  |c Gerd U. Auffarth, Florian N. Auerbach, Tanja Rabsilber, José A. Gegúndez, Ricardo Cuiña, Yves Renard, Paolo Vinciguerra, Fabrizio Camesasca, Francoise Van Cauwenberge, Thierry Amzallag, Gysbert Van Setten, Mike P. Holzer 
264 1 |c 2017 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 23.08.2018 
520 |a PURPOSE: To compare the clinical performance and safety of 2 ophthalmic viscosurgical devices (OVDs)-Twinvisc (OVD 1) and Duovisc (OVD 2)-in cataract surgery. SETTING: European multicenter study. DESIGN: Prospective randomized controlled study. METHODS: Patients with cataract had phacoemulsification and intraocular lens implantation in 1 eye. They were randomly assigned to receive OVD 1 or OVD 2. Preoperative and postoperative examinations over 3 months included mean intraocular pressure (IOP), incidence of IOP peaks (≥30 mm Hg and ≥24 mm Hg), endothelial cell count (ECC), corneal thickness, and intraocular inflammation. A subjective evaluation of the OVDs was performed. RESULTS: The study comprised 220 patients. The incidence of IOP peaks and the mean IOP were not statistically significantly different between the 2 groups at any of the follow-up visits. At 6 hours, the incidence of IOP spikes 30 mm Hg or higher was 6.5% and 7.2% in the OVD 1 and the OVD 2 groups, respectively (P = .846). For the IOP spikes 24 mm Hg or higher, the incidence was 16.8% and 25.2%, respectively (P = .128). Three months postoperatively there was no statistically significant difference in ECC and pachymetry between the 2 groups. Mild inflammation was noticed up to 7 days postoperatively after which it resolved in both groups. Subjectively, the OVD 2 was easier to use, whereas the OVD 1 had better cohesive and dispersive properties. CONCLUSIONS: Both OVDs have similar performance and safety profiles in phacoemulsification cataract surgery. No clinically relevant differences were found between the 2 devices regarding transient IOP spikes, mean IOP, corneal endothelium injury, or inflammation. 
700 1 |a Auerbach, Florian Niklas  |d 1982-  |e VerfasserIn  |0 (DE-588)1072190079  |0 (DE-627)827016891  |0 (DE-576)433686073  |4 aut 
700 1 |a Rabsilber, Tanja Marina  |d 1977-  |e VerfasserIn  |0 (DE-588)128743271  |0 (DE-627)378689541  |0 (DE-576)297309609  |4 aut 
700 1 |a Holzer, Mike P.  |d 1973-  |e VerfasserIn  |0 (DE-588)122217527  |0 (DE-627)705818640  |0 (DE-576)293157812  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cataract and refractive surgery  |d Hagerstown, MD : Wolters Kluwer Health, 1986  |g 43(2017), 1, Seite 87-94  |h Online-Ressource  |w (DE-627)320594203  |w (DE-600)2019330-0  |w (DE-576)260773891  |x 1873-4502  |7 nnas  |a Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery 
773 1 8 |g volume:43  |g year:2017  |g number:1  |g pages:87-94  |g extent:8  |a Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery 
856 4 0 |u http://dx.doi.org/10.1016/j.jcrs.2016.10.025  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20180823 
993 |a Article 
994 |a 2017 
998 |g 122217527  |a Holzer, Mike P.  |m 122217527:Holzer, Mike P.  |d 910000  |d 910900  |e 910000PH122217527  |e 910900PH122217527  |k 0/910000/  |k 1/910000/910900/  |p 12  |y j 
998 |g 128743271  |a Rabsilber, Tanja Marina  |m 128743271:Rabsilber, Tanja Marina  |d 910000  |d 910900  |e 910000PR128743271  |e 910900PR128743271  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 1072190079  |a Auerbach, Florian Niklas  |m 1072190079:Auerbach, Florian Niklas  |d 910000  |d 910900  |e 910000PA1072190079  |e 910900PA1072190079  |k 0/910000/  |k 1/910000/910900/  |p 2 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1580340091  |e 302302670X 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"disp":"Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgeryJournal of cataract and refractive surgery","title":[{"title_sort":"Journal of cataract and refractive surgery","title":"Journal of cataract and refractive surgery"}],"name":{"displayForm":["American Society of Cataract and Refractive Surgery"]},"id":{"zdb":["2019330-0"],"eki":["320594203"],"issn":["1873-4502"]},"part":{"year":"2017","text":"43(2017), 1, Seite 87-94","pages":"87-94","issue":"1","extent":"8","volume":"43"},"origin":[{"dateIssuedDisp":"2020-","publisher":"Wolters Kluwer Health ; American Society of Cataract and Refractive Surgery ; Elsevier","publisherPlace":"Hagerstown, MD ; Fairfax, Va ; Amsterdam [u.a.]","dateIssuedKey":"2020"}],"pubHistory":["12.1986 -"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"titleAlt":[{"title":"Journal of cataract & refractive surgery"}],"note":["Gesehen am 02.08.24"],"recId":"320594203","physDesc":[{"extent":"Online-Ressource"}]}],"recId":"1580340091","physDesc":[{"extent":"8 S."}],"note":["Gesehen am 23.08.2018"],"language":["eng"],"origin":[{"dateIssuedDisp":"2017","dateIssuedKey":"2017"}],"person":[{"role":"aut","display":"Auffarth, Gerd U.","family":"Auffarth","given":"Gerd U."},{"family":"Auerbach","role":"aut","display":"Auerbach, Florian Niklas","given":"Florian Niklas"},{"given":"Tanja Marina","family":"Rabsilber","display":"Rabsilber, Tanja Marina","role":"aut"},{"family":"Holzer","display":"Holzer, Mike P.","role":"aut","given":"Mike P."}],"id":{"doi":["10.1016/j.jcrs.2016.10.025"],"eki":["1580340091"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"name":{"displayForm":["Gerd U. Auffarth, Florian N. Auerbach, Tanja Rabsilber, José A. Gegúndez, Ricardo Cuiña, Yves Renard, Paolo Vinciguerra, Fabrizio Camesasca, Francoise Van Cauwenberge, Thierry Amzallag, Gysbert Van Setten, Mike P. Holzer"]},"title":[{"title":"Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery","title_sort":"Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery"}]} 
SRT |a AUFFARTHGECOMPARISON2017