Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery
PURPOSE: To compare the clinical performance and safety of 2 ophthalmic viscosurgical devices (OVDs)-Twinvisc (OVD 1) and Duovisc (OVD 2)-in cataract surgery. SETTING: European multicenter study. DESIGN: Prospective randomized controlled study. METHODS: Patients with cataract had phacoemulsification...
Gespeichert in:
| Hauptverfasser: | , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2017
|
| In: |
Journal of cataract and refractive surgery
Year: 2017, Jahrgang: 43, Heft: 1, Pages: 87-94 |
| ISSN: | 1873-4502 |
| DOI: | 10.1016/j.jcrs.2016.10.025 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1016/j.jcrs.2016.10.025 |
| Verfasserangaben: | Gerd U. Auffarth, Florian N. Auerbach, Tanja Rabsilber, José A. Gegúndez, Ricardo Cuiña, Yves Renard, Paolo Vinciguerra, Fabrizio Camesasca, Francoise Van Cauwenberge, Thierry Amzallag, Gysbert Van Setten, Mike P. Holzer |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1580340091 | ||
| 003 | DE-627 | ||
| 005 | 20240316100513.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180823s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jcrs.2016.10.025 |2 doi | |
| 035 | |a (DE-627)1580340091 | ||
| 035 | |a (DE-576)510340091 | ||
| 035 | |a (DE-599)BSZ510340091 | ||
| 035 | |a (OCoLC)1341017590 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Auffarth, Gerd U. |d 1964- |e VerfasserIn |0 (DE-588)123385261 |0 (DE-627)577130420 |0 (DE-576)293687277 |4 aut | |
| 245 | 1 | 0 | |a Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery |c Gerd U. Auffarth, Florian N. Auerbach, Tanja Rabsilber, José A. Gegúndez, Ricardo Cuiña, Yves Renard, Paolo Vinciguerra, Fabrizio Camesasca, Francoise Van Cauwenberge, Thierry Amzallag, Gysbert Van Setten, Mike P. Holzer |
| 264 | 1 | |c 2017 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 23.08.2018 | ||
| 520 | |a PURPOSE: To compare the clinical performance and safety of 2 ophthalmic viscosurgical devices (OVDs)-Twinvisc (OVD 1) and Duovisc (OVD 2)-in cataract surgery. SETTING: European multicenter study. DESIGN: Prospective randomized controlled study. METHODS: Patients with cataract had phacoemulsification and intraocular lens implantation in 1 eye. They were randomly assigned to receive OVD 1 or OVD 2. Preoperative and postoperative examinations over 3 months included mean intraocular pressure (IOP), incidence of IOP peaks (≥30 mm Hg and ≥24 mm Hg), endothelial cell count (ECC), corneal thickness, and intraocular inflammation. A subjective evaluation of the OVDs was performed. RESULTS: The study comprised 220 patients. The incidence of IOP peaks and the mean IOP were not statistically significantly different between the 2 groups at any of the follow-up visits. At 6 hours, the incidence of IOP spikes 30 mm Hg or higher was 6.5% and 7.2% in the OVD 1 and the OVD 2 groups, respectively (P = .846). For the IOP spikes 24 mm Hg or higher, the incidence was 16.8% and 25.2%, respectively (P = .128). Three months postoperatively there was no statistically significant difference in ECC and pachymetry between the 2 groups. Mild inflammation was noticed up to 7 days postoperatively after which it resolved in both groups. Subjectively, the OVD 2 was easier to use, whereas the OVD 1 had better cohesive and dispersive properties. CONCLUSIONS: Both OVDs have similar performance and safety profiles in phacoemulsification cataract surgery. No clinically relevant differences were found between the 2 devices regarding transient IOP spikes, mean IOP, corneal endothelium injury, or inflammation. | ||
| 700 | 1 | |a Auerbach, Florian Niklas |d 1982- |e VerfasserIn |0 (DE-588)1072190079 |0 (DE-627)827016891 |0 (DE-576)433686073 |4 aut | |
| 700 | 1 | |a Rabsilber, Tanja Marina |d 1977- |e VerfasserIn |0 (DE-588)128743271 |0 (DE-627)378689541 |0 (DE-576)297309609 |4 aut | |
| 700 | 1 | |a Holzer, Mike P. |d 1973- |e VerfasserIn |0 (DE-588)122217527 |0 (DE-627)705818640 |0 (DE-576)293157812 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of cataract and refractive surgery |d Hagerstown, MD : Wolters Kluwer Health, 1986 |g 43(2017), 1, Seite 87-94 |h Online-Ressource |w (DE-627)320594203 |w (DE-600)2019330-0 |w (DE-576)260773891 |x 1873-4502 |7 nnas |a Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery |
| 773 | 1 | 8 | |g volume:43 |g year:2017 |g number:1 |g pages:87-94 |g extent:8 |a Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jcrs.2016.10.025 |x Verlag |x Resolving-System |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180823 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 122217527 |a Holzer, Mike P. |m 122217527:Holzer, Mike P. |d 910000 |d 910900 |e 910000PH122217527 |e 910900PH122217527 |k 0/910000/ |k 1/910000/910900/ |p 12 |y j | ||
| 998 | |g 128743271 |a Rabsilber, Tanja Marina |m 128743271:Rabsilber, Tanja Marina |d 910000 |d 910900 |e 910000PR128743271 |e 910900PR128743271 |k 0/910000/ |k 1/910000/910900/ |p 3 | ||
| 998 | |g 1072190079 |a Auerbach, Florian Niklas |m 1072190079:Auerbach, Florian Niklas |d 910000 |d 910900 |e 910000PA1072190079 |e 910900PA1072190079 |k 0/910000/ |k 1/910000/910900/ |p 2 | ||
| 998 | |g 123385261 |a Auffarth, Gerd U. |m 123385261:Auffarth, Gerd U. |d 910000 |d 910900 |e 910000PA123385261 |e 910900PA123385261 |k 0/910000/ |k 1/910000/910900/ |p 1 |x j | ||
| 999 | |a KXP-PPN1580340091 |e 302302670X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"disp":"Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgeryJournal of cataract and refractive surgery","title":[{"title_sort":"Journal of cataract and refractive surgery","title":"Journal of cataract and refractive surgery"}],"name":{"displayForm":["American Society of Cataract and Refractive Surgery"]},"id":{"zdb":["2019330-0"],"eki":["320594203"],"issn":["1873-4502"]},"part":{"year":"2017","text":"43(2017), 1, Seite 87-94","pages":"87-94","issue":"1","extent":"8","volume":"43"},"origin":[{"dateIssuedDisp":"2020-","publisher":"Wolters Kluwer Health ; American Society of Cataract and Refractive Surgery ; Elsevier","publisherPlace":"Hagerstown, MD ; Fairfax, Va ; Amsterdam [u.a.]","dateIssuedKey":"2020"}],"pubHistory":["12.1986 -"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"titleAlt":[{"title":"Journal of cataract & refractive surgery"}],"note":["Gesehen am 02.08.24"],"recId":"320594203","physDesc":[{"extent":"Online-Ressource"}]}],"recId":"1580340091","physDesc":[{"extent":"8 S."}],"note":["Gesehen am 23.08.2018"],"language":["eng"],"origin":[{"dateIssuedDisp":"2017","dateIssuedKey":"2017"}],"person":[{"role":"aut","display":"Auffarth, Gerd U.","family":"Auffarth","given":"Gerd U."},{"family":"Auerbach","role":"aut","display":"Auerbach, Florian Niklas","given":"Florian Niklas"},{"given":"Tanja Marina","family":"Rabsilber","display":"Rabsilber, Tanja Marina","role":"aut"},{"family":"Holzer","display":"Holzer, Mike P.","role":"aut","given":"Mike P."}],"id":{"doi":["10.1016/j.jcrs.2016.10.025"],"eki":["1580340091"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"name":{"displayForm":["Gerd U. Auffarth, Florian N. Auerbach, Tanja Rabsilber, José A. Gegúndez, Ricardo Cuiña, Yves Renard, Paolo Vinciguerra, Fabrizio Camesasca, Francoise Van Cauwenberge, Thierry Amzallag, Gysbert Van Setten, Mike P. Holzer"]},"title":[{"title":"Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery","title_sort":"Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery"}]} | ||
| SRT | |a AUFFARTHGECOMPARISON2017 | ||