New bone post-processing tools in forensic imaging: a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment
PurposeThe aim of this multi-reader feasibility study was to evaluate new post-processing CT imaging tools in rib fracture assessment of forensic cases by analyzing detection time and diagnostic accuracy.Materials and methodsThirty autopsy cases (20 with and 10 without rib fractures in autopsy) were...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2017
|
| In: |
International journal of legal medicine
Year: 2017, Jahrgang: 131, Heft: 2, Pages: 489-496 |
| ISSN: | 1437-1596 |
| DOI: | 10.1007/s00414-016-1412-6 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1007/s00414-016-1412-6 Verlag, Volltext: https://link.springer.com/article/10.1007%2Fs00414-016-1412-6 |
| Verfasserangaben: | Philip A. Glemser, Michael Pfleiderer, Anna Heger, Jan Tremper, Astrid Krauskopf, Heinz-Peter Schlemmer, Kathrin Yen, David Simons |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1580447872 | ||
| 003 | DE-627 | ||
| 005 | 20230427065700.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180828s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00414-016-1412-6 |2 doi | |
| 035 | |a (DE-627)1580447872 | ||
| 035 | |a (DE-576)510447872 | ||
| 035 | |a (DE-599)BSZ510447872 | ||
| 035 | |a (OCoLC)1341017727 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Glemser, Philip |e VerfasserIn |0 (DE-588)1029777756 |0 (DE-627)734092520 |0 (DE-576)377624667 |4 aut | |
| 245 | 1 | 0 | |a New bone post-processing tools in forensic imaging |b a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment |c Philip A. Glemser, Michael Pfleiderer, Anna Heger, Jan Tremper, Astrid Krauskopf, Heinz-Peter Schlemmer, Kathrin Yen, David Simons |
| 264 | 1 | |c 2017 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Published online: 22 July 2016 | ||
| 520 | |a PurposeThe aim of this multi-reader feasibility study was to evaluate new post-processing CT imaging tools in rib fracture assessment of forensic cases by analyzing detection time and diagnostic accuracy.Materials and methodsThirty autopsy cases (20 with and 10 without rib fractures in autopsy) were randomly selected and included in this study. All cases received a native whole body CT scan prior to the autopsy procedure, which included dissection and careful evaluation of each rib. In addition to standard transverse sections (modality A), CT images were subjected to a reconstruction algorithm to compute axial labelling of the ribs (modality B) as well as “unfolding” visualizations of the rib cage (modality C, “eagle tool”). Three radiologists with different clinical and forensic experience who were blinded to autopsy results evaluated all cases in a random manner of modality and case.ResultsRib fracture assessment of each reader was evaluated compared to autopsy and a CT consensus read as radiologic reference. A detailed evaluation of relevant test parameters revealed a better accordance to the CT consensus read as to the autopsy. Modality C was the significantly quickest rib fracture detection modality despite slightly reduced statistic test parameters compared to modalities A and B.ConclusionModern CT post-processing software is able to shorten reading time and to increase sensitivity and specificity compared to standard autopsy alone. The eagle tool as an easy to use tool is suited for an initial rib fracture screening prior to autopsy and can therefore be beneficial for forensic pathologists. | ||
| 650 | 4 | |a Computed tomography | |
| 650 | 4 | |a Forensic imaging | |
| 650 | 4 | |a Post-processing software | |
| 650 | 4 | |a Rib fractures | |
| 700 | 1 | |a Pfleiderer, Michael |e VerfasserIn |0 (DE-588)1165792583 |0 (DE-627)1029856982 |0 (DE-576)51044721X |4 aut | |
| 700 | 1 | |a Heger, Anna |e VerfasserIn |0 (DE-588)1165801183 |0 (DE-627)1029864551 |0 (DE-576)510447503 |4 aut | |
| 700 | 1 | |a Krauskopf, Astrid |e VerfasserIn |0 (DE-588)1115376047 |0 (DE-627)86976232X |0 (DE-576)477776094 |4 aut | |
| 700 | 1 | |a Schlemmer, Heinz-Peter |d 1961- |e VerfasserIn |0 (DE-588)1025559967 |0 (DE-627)722927142 |0 (DE-576)17334805X |4 aut | |
| 700 | 1 | |a Yen, Kathrin |e VerfasserIn |0 (DE-588)106866066X |0 (DE-627)82057869X |0 (DE-576)427995957 |4 aut | |
| 700 | 1 | |a Simons, David |e VerfasserIn |0 (DE-588)142618438 |0 (DE-627)638043085 |0 (DE-576)332397521 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t International journal of legal medicine |d Berlin : Springer, 1990 |g 131(2017), 2, Seite 489-496 |h Online-Ressource |w (DE-627)253724295 |w (DE-600)1459222-8 |w (DE-576)072373148 |x 1437-1596 |7 nnas |a New bone post-processing tools in forensic imaging a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment |
| 773 | 1 | 8 | |g volume:131 |g year:2017 |g number:2 |g pages:489-496 |g extent:8 |a New bone post-processing tools in forensic imaging a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00414-016-1412-6 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://link.springer.com/article/10.1007%2Fs00414-016-1412-6 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180828 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 142618438 |a Simons, David |m 142618438:Simons, David |d 50000 |e 50000PS142618438 |k 0/50000/ |p 8 |y j | ||
| 998 | |g 106866066X |a Yen, Kathrin |m 106866066X:Yen, Kathrin |d 910000 |d 912100 |e 910000PY106866066X |e 912100PY106866066X |k 0/910000/ |k 1/910000/912100/ |p 7 | ||
| 998 | |g 1025559967 |a Schlemmer, Heinz-Peter |m 1025559967:Schlemmer, Heinz-Peter |d 50000 |e 50000PS1025559967 |k 0/50000/ |p 6 | ||
| 998 | |g 1115376047 |a Krauskopf, Astrid |m 1115376047:Krauskopf, Astrid |d 910000 |d 912100 |e 910000PK1115376047 |e 912100PK1115376047 |k 0/910000/ |k 1/910000/912100/ |p 5 | ||
| 998 | |g 1165801183 |a Heger, Anna |m 1165801183:Heger, Anna |d 910000 |d 912100 |e 910000PH1165801183 |e 912100PH1165801183 |k 0/910000/ |k 1/910000/912100/ |p 3 | ||
| 998 | |g 1165792583 |a Pfleiderer, Michael |m 1165792583:Pfleiderer, Michael |p 2 | ||
| 998 | |g 1029777756 |a Glemser, Philip |m 1029777756:Glemser, Philip |d 910000 |d 911400 |e 910000PG1029777756 |e 911400PG1029777756 |k 0/910000/ |k 1/910000/911400/ |p 1 |x j | ||
| 999 | |a KXP-PPN1580447872 |e 3024048553 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"display":"Glemser, Philip","family":"Glemser","given":"Philip","role":"aut"},{"display":"Pfleiderer, Michael","family":"Pfleiderer","role":"aut","given":"Michael"},{"family":"Heger","display":"Heger, Anna","given":"Anna","role":"aut"},{"given":"Astrid","role":"aut","family":"Krauskopf","display":"Krauskopf, Astrid"},{"given":"Heinz-Peter","role":"aut","family":"Schlemmer","display":"Schlemmer, Heinz-Peter"},{"display":"Yen, Kathrin","family":"Yen","role":"aut","given":"Kathrin"},{"display":"Simons, David","family":"Simons","role":"aut","given":"David"}],"language":["eng"],"title":[{"title":"New bone post-processing tools in forensic imaging","title_sort":"New bone post-processing tools in forensic imaging","subtitle":"a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment"}],"note":["Published online: 22 July 2016"],"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"2017"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"8 S."}],"name":{"displayForm":["Philip A. Glemser, Michael Pfleiderer, Anna Heger, Jan Tremper, Astrid Krauskopf, Heinz-Peter Schlemmer, Kathrin Yen, David Simons"]},"recId":"1580447872","relHost":[{"origin":[{"dateIssuedDisp":"1990-","publisher":"Springer ; HeinOnline ; Springer","dateIssuedKey":"1990","publisherPlace":"Berlin ; Heidelberg ; Getzville, NY ; Berlin ; Heidelberg ; New York, NY"}],"note":["Gesehen am 06.03.25","Volltext auch als Teil einer Datenbank verfügbar"],"pubHistory":["Volume 104, issue 1 (January 1990)-"],"title":[{"title_sort":"International journal of legal medicine","subtitle":"official publication of the International Academy of Legal Medicine","title":"International journal of legal medicine"}],"disp":"New bone post-processing tools in forensic imaging a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessmentInternational journal of legal medicine","type":{"media":"Online-Ressource","bibl":"periodical"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"253724295","id":{"eki":["253724295"],"zdb":["1459222-8"],"issn":["1437-1596"]},"language":["eng","ger"],"titleAlt":[{"title":"Legal medicine"}],"part":{"text":"131(2017), 2, Seite 489-496","issue":"2","year":"2017","pages":"489-496","extent":"8","volume":"131"}}],"id":{"eki":["1580447872"],"doi":["10.1007/s00414-016-1412-6"]}} | ||
| SRT | |a GLEMSERPHINEWBONEPOS2017 | ||