Imaging of patients with complex hemodialysis arterio-venous fistulas using time-resolved dynamic CT angiography: comparison with duplex ultrasound
To evaluate the feasibility and potential on therapy management of time-resolved dynamic computed tomography angiography (dCTA) in patients with forearm arterio-venous fistula (AVF)/arterio-venous grafts (AVG). Thirty-five patients with complex failing forearm AVF/AVGs were examined with ultrasound...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
02 October 2017
|
| In: |
Scientific reports
Year: 2017, Jahrgang: 7 |
| ISSN: | 2045-2322 |
| DOI: | 10.1038/s41598-017-12902-6 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1038/s41598-017-12902-6 Verlag, kostenfrei, Volltext: http://www-nature-com/articles/s41598-017-12902-6 |
| Verfasserangaben: | Mathias Meyer, Nicole Geiger, Urs Benck, Daniela Rose, Sonja Sudarski, Melissa M. Ong, Stefan O. Schoenberg and Thomas Henzler |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 158053886X | ||
| 003 | DE-627 | ||
| 005 | 20220814235751.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180830s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1038/s41598-017-12902-6 |2 doi | |
| 035 | |a (DE-627)158053886X | ||
| 035 | |a (DE-576)51053886X | ||
| 035 | |a (DE-599)BSZ51053886X | ||
| 035 | |a (OCoLC)1341017894 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Meyer, Mathias |d 1986- |e VerfasserIn |0 (DE-588)1025310306 |0 (DE-627)722026021 |0 (DE-576)370193059 |4 aut | |
| 245 | 1 | 0 | |a Imaging of patients with complex hemodialysis arterio-venous fistulas using time-resolved dynamic CT angiography |b comparison with duplex ultrasound |c Mathias Meyer, Nicole Geiger, Urs Benck, Daniela Rose, Sonja Sudarski, Melissa M. Ong, Stefan O. Schoenberg and Thomas Henzler |
| 264 | 1 | |c 02 October 2017 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 30.08.2018 | ||
| 520 | |a To evaluate the feasibility and potential on therapy management of time-resolved dynamic computed tomography angiography (dCTA) in patients with forearm arterio-venous fistula (AVF)/arterio-venous grafts (AVG). Thirty-five patients with complex failing forearm AVF/AVGs were examined with ultrasound and a dCTA protocol. Diagnosis and therapy management was evaluated versus duplex ultrasound (DUS) in three different readouts: 1. all dCTA datasets; 2. one arterial phase of the dCTA dataset; 3. one arterial and one venous dataset out of the dCTA dataset. All reads were performed >30 days apart from each other. Using all data of the dCTA examination, 20 patients were classified as having a stenosis >50%, 12 high-shunt flow, 11 partial thrombosis, 5 venous aneurysms and 5 complete thrombosis of their AVF/AVG grafts. This lead to 13 additional pathologic findings not visible on DUS and reclassification as normal in one patient with suspected AVF stenosis and complete thrombus on DUS. These additional findings lead to a direct change of therapeutic management in 8 patients. Compared to readout 1 (53 pathologies), readout number 2 and 3 revealed only 33 and 41 pathologies, respectively. dCTA provides additional information, improving diagnostic confidence and leading to changes in therapy management when compared to DUS alone. | ||
| 700 | 1 | |a Geiger, Nicole |d 1969- |e VerfasserIn |0 (DE-588)130519650 |0 (DE-627)503036544 |0 (DE-576)190002727 |4 aut | |
| 700 | 1 | |a Benck, Urs Tobias |d 1966- |e VerfasserIn |0 (DE-588)130899143 |0 (DE-627)707596653 |0 (DE-576)298403293 |4 aut | |
| 700 | 1 | |a Rose, Daniela |d 1975- |e VerfasserIn |0 (DE-588)124795455 |0 (DE-627)366424882 |0 (DE-576)29450673X |4 aut | |
| 700 | 1 | |a Janssen, Sonja |d 1987- |e VerfasserIn |0 (DE-588)1033103748 |0 (DE-627)74078871X |0 (DE-576)380756110 |4 aut | |
| 700 | 1 | |a Meyer, Melissa |d 1985- |e VerfasserIn |0 (DE-588)1056026561 |0 (DE-627)793161266 |0 (DE-576)412039613 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Henzler, Thomas |d 1980- |e VerfasserIn |0 (DE-588)134001486 |0 (DE-627)559468415 |0 (DE-576)276829948 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Scientific reports |d [London] : Springer Nature, 2011 |g 7(2017) Artikel-Nummer 12563, 11 Seiten |h Online-Ressource |w (DE-627)663366712 |w (DE-600)2615211-3 |w (DE-576)346641179 |x 2045-2322 |7 nnas |a Imaging of patients with complex hemodialysis arterio-venous fistulas using time-resolved dynamic CT angiography comparison with duplex ultrasound |
| 773 | 1 | 8 | |g volume:7 |g year:2017 |g extent:11 |a Imaging of patients with complex hemodialysis arterio-venous fistulas using time-resolved dynamic CT angiography comparison with duplex ultrasound |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1038/s41598-017-12902-6 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u http://www-nature-com/articles/s41598-017-12902-6 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180830 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 134001486 |a Henzler, Thomas |m 134001486:Henzler, Thomas |d 60000 |e 60000PH134001486 |k 0/60000/ |p 8 |y j | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 7 | ||
| 998 | |g 1056026561 |a Meyer, Melissa |m 1056026561:Meyer, Melissa |d 60000 |d 62900 |e 60000PM1056026561 |e 62900PM1056026561 |k 0/60000/ |k 1/60000/62900/ |p 6 | ||
| 998 | |g 1033103748 |a Janssen, Sonja |m 1033103748:Janssen, Sonja |d 60000 |d 62900 |e 60000PJ1033103748 |e 62900PJ1033103748 |k 0/60000/ |k 1/60000/62900/ |p 5 | ||
| 998 | |g 124795455 |a Rose, Daniela |m 124795455:Rose, Daniela |d 60000 |d 61400 |e 60000PR124795455 |e 61400PR124795455 |k 0/60000/ |k 1/60000/61400/ |p 4 | ||
| 998 | |g 130899143 |a Benck, Urs Tobias |m 130899143:Benck, Urs Tobias |d 60000 |d 61400 |e 60000PB130899143 |e 61400PB130899143 |k 0/60000/ |k 1/60000/61400/ |p 3 | ||
| 998 | |g 130519650 |a Geiger, Nicole |m 130519650:Geiger, Nicole |p 2 | ||
| 998 | |g 1025310306 |a Meyer, Mathias |m 1025310306:Meyer, Mathias |d 60000 |d 62900 |e 60000PM1025310306 |e 62900PM1025310306 |k 0/60000/ |k 1/60000/62900/ |p 1 |x j | ||
| 999 | |a KXP-PPN158053886X |e 3024191933 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"physDesc":[{"extent":"11 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["158053886X"],"doi":["10.1038/s41598-017-12902-6"]},"relHost":[{"recId":"663366712","disp":"Imaging of patients with complex hemodialysis arterio-venous fistulas using time-resolved dynamic CT angiography comparison with duplex ultrasoundScientific reports","language":["eng"],"pubHistory":["1, article number 1 (2011)-"],"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"publisherPlace":"[London] ; London","dateIssuedKey":"2011","dateIssuedDisp":"2011-","publisher":"Springer Nature ; Nature Publishing Group"}],"title":[{"title":"Scientific reports","title_sort":"Scientific reports"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["663366712"],"zdb":["2615211-3"],"issn":["2045-2322"]},"part":{"extent":"11","year":"2017","volume":"7","text":"7(2017) Artikel-Nummer 12563, 11 Seiten"},"note":["Gesehen am 12.07.24"]}],"note":["Gesehen am 30.08.2018"],"person":[{"given":"Mathias","display":"Meyer, Mathias","family":"Meyer","role":"aut"},{"given":"Nicole","display":"Geiger, Nicole","family":"Geiger","role":"aut"},{"given":"Urs Tobias","display":"Benck, Urs Tobias","family":"Benck","role":"aut"},{"role":"aut","given":"Daniela","display":"Rose, Daniela","family":"Rose"},{"role":"aut","family":"Janssen","display":"Janssen, Sonja","given":"Sonja"},{"family":"Meyer","given":"Melissa","display":"Meyer, Melissa","role":"aut"},{"role":"aut","display":"Schönberg, Stefan","given":"Stefan","family":"Schönberg"},{"family":"Henzler","display":"Henzler, Thomas","given":"Thomas","role":"aut"}],"recId":"158053886X","origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"02 October 2017"}],"name":{"displayForm":["Mathias Meyer, Nicole Geiger, Urs Benck, Daniela Rose, Sonja Sudarski, Melissa M. Ong, Stefan O. Schoenberg and Thomas Henzler"]},"language":["eng"],"title":[{"subtitle":"comparison with duplex ultrasound","title_sort":"Imaging of patients with complex hemodialysis arterio-venous fistulas using time-resolved dynamic CT angiography","title":"Imaging of patients with complex hemodialysis arterio-venous fistulas using time-resolved dynamic CT angiography"}]} | ||
| SRT | |a MEYERMATHIIMAGINGOFP0220 | ||