3D dosimetric validation of motion compensation concepts in radiotherapy using an anthropomorphic dynamic lung phantom

In this study, we developed a new setup for the validation of clinical workflows in adaptive radiation therapy, which combines a dynamic ex vivo porcine lung phantom and three-dimensional (3D) polymer gel dosimetry. The phantom consists of an artificial PMMA-thorax and contains a post mortem explant...

Full description

Saved in:
Bibliographic Details
Main Authors: Mann, Philipp (Author) , Witte, Maximilian (Author) , Moser, Torsten (Author) , Lang, Clemens (Author) , Runz, Armin (Author) , Johnen, Wibke (Author) , Biederer, Jürgen (Author) , Karger, Christian (Author)
Format: Article (Journal)
Language:English
Published: 2017
In: Physics in medicine and biology
Year: 2016, Volume: 62, Issue: 2, Pages: 573-595
ISSN:1361-6560
DOI:10.1088/1361-6560/aa51b1
Online Access:Verlag, Volltext: http://dx.doi.org/10.1088/1361-6560/aa51b1
Verlag, Volltext: http://stacks.iop.org/0031-9155/62/i=2/a=573
Get full text
Author Notes:P. Mann, M. Witte, T. Moser, C. Lang, A. Runz, W. Johnen, M. Berger, J. Biederer and C.P. Karger

MARC

LEADER 00000caa a2200000 c 4500
001 1580994067
003 DE-627
005 20220815011720.0
007 cr uuu---uuuuu
008 180914r20172016xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/aa51b1  |2 doi 
035 |a (DE-627)1580994067 
035 |a (DE-576)510994067 
035 |a (DE-599)BSZ510994067 
035 |a (OCoLC)1341018366 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mann, Philipp  |e VerfasserIn  |0 (DE-588)1133588158  |0 (DE-627)889511675  |0 (DE-576)489523056  |4 aut 
245 1 0 |a 3D dosimetric validation of motion compensation concepts in radiotherapy using an anthropomorphic dynamic lung phantom  |c P. Mann, M. Witte, T. Moser, C. Lang, A. Runz, W. Johnen, M. Berger, J. Biederer and C.P. Karger 
264 1 |c 2017 
300 |a 23 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published 29 December 2016 
500 |a Gesehen am 14.09.2018 
520 |a In this study, we developed a new setup for the validation of clinical workflows in adaptive radiation therapy, which combines a dynamic ex vivo porcine lung phantom and three-dimensional (3D) polymer gel dosimetry. The phantom consists of an artificial PMMA-thorax and contains a post mortem explanted porcine lung to which arbitrary breathing patterns can be applied. A lung tumor was simulated using the PAGAT (polyacrylamide gelatin gel fabricated at atmospheric conditions) dosimetry gel, which was evaluated in three dimensions by magnetic resonance imaging (MRI). To avoid bias by reaction with oxygen and other materials, the gel was collocated inside a BAREX ™ container. For calibration purposes, the same containers with eight gel samples were irradiated with doses from 0 to 7 Gy. To test the technical feasibility of the system, a small spherical dose distribution located completely within the gel volume was planned. Dose delivery was performed under static and dynamic conditions of the phantom with and without motion compensation by beam gating. To verify clinical target definition and motion compensation concepts, the entire gel volume was homogeneously irradiated applying adequate margins in case of the static phantom and an additional internal target volume in case of dynamically operated phantom without and with gated beam delivery. MR-evaluation of the gel samples and comparison of the resulting 3D dose distribution with the planned dose distribution revealed a good agreement for the static phantom. In case of the dynamically operated phantom without motion compensation, agreement was very poor while additional application of motion compensation techniques restored the good agreement between measured and planned dose. From these experiments it was concluded that the set up with the dynamic and anthropomorphic lung phantom together with 3D-gel dosimetry provides a valuable and versatile tool for geometrical and dosimetrical validation of motion compensated treatment concepts in adaptive radiotherapy. 
534 |c 2016 
700 1 |a Witte, Maximilian  |e VerfasserIn  |0 (DE-588)1167001206  |0 (DE-627)1030847797  |0 (DE-576)510994806  |4 aut 
700 1 |a Moser, Torsten  |d 1970-  |e VerfasserIn  |0 (DE-588)1013138104  |0 (DE-627)704967111  |0 (DE-576)346071933  |4 aut 
700 1 |a Lang, Clemens  |e VerfasserIn  |0 (DE-588)1166999858  |0 (DE-627)1030846715  |0 (DE-576)510993885  |4 aut 
700 1 |a Runz, Armin  |e VerfasserIn  |0 (DE-588)116699953X  |0 (DE-627)1030846480  |0 (DE-576)510993516  |4 aut 
700 1 |a Johnen, Wibke  |e VerfasserIn  |0 (DE-588)1166999270  |0 (DE-627)1030846324  |0 (DE-576)510993192  |4 aut 
700 1 |a Biederer, Jürgen  |d 1969-  |e VerfasserIn  |0 (DE-588)141247282  |0 (DE-627)625830857  |0 (DE-576)322978122  |4 aut 
700 1 |a Karger, Christian  |e VerfasserIn  |0 (DE-588)1077113641  |0 (DE-627)836027280  |0 (DE-576)170866459  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 62(2017), 2, Seite 573-595  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a 3D dosimetric validation of motion compensation concepts in radiotherapy using an anthropomorphic dynamic lung phantom 
773 1 8 |g volume:62  |g year:2017  |g number:2  |g pages:573-595  |g extent:23  |a 3D dosimetric validation of motion compensation concepts in radiotherapy using an anthropomorphic dynamic lung phantom 
856 4 0 |u http://dx.doi.org/10.1088/1361-6560/aa51b1  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://stacks.iop.org/0031-9155/62/i=2/a=573  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180914 
993 |a Article 
994 |a 2017 
998 |g 1077113641  |a Karger, Christian  |m 1077113641:Karger, Christian  |d 50000  |e 50000PK1077113641  |k 0/50000/  |p 9  |y j 
998 |g 141247282  |a Biederer, Jürgen  |m 141247282:Biederer, Jürgen  |d 910000  |d 911400  |e 910000PB141247282  |e 911400PB141247282  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 1166999270  |a Johnen, Wibke  |m 1166999270:Johnen, Wibke  |d 910000  |e 910000PJ1166999270  |k 0/910000/  |p 6 
998 |g 116699953X  |a Runz, Armin  |m 116699953X:Runz, Armin  |p 5 
998 |g 1166999858  |a Lang, Clemens  |m 1166999858:Lang, Clemens  |p 4 
998 |g 1013138104  |a Moser, Torsten  |m 1013138104:Moser, Torsten  |d 910000  |e 910000PM1013138104  |k 0/910000/  |p 3 
998 |g 1167001206  |a Witte, Maximilian  |m 1167001206:Witte, Maximilian  |d 910000  |e 910000PW1167001206  |k 0/910000/  |p 2 
998 |g 1133588158  |a Mann, Philipp  |m 1133588158:Mann, Philipp  |p 1  |x j 
999 |a KXP-PPN1580994067  |e 3025578572 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["P. Mann, M. Witte, T. Moser, C. Lang, A. Runz, W. Johnen, M. Berger, J. Biederer and C.P. Karger"]},"id":{"doi":["10.1088/1361-6560/aa51b1"],"eki":["1580994067"]},"relHost":[{"origin":[{"dateIssuedKey":"1956","publisherPlace":"Bristol","dateIssuedDisp":"1956-","publisher":"IOP Publ."}],"pubHistory":["1.1956 -"],"id":{"eki":["269016163"],"issn":["1361-6560"],"zdb":["1473501-5"]},"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title_sort":"Physics in medicine and biology","title":"Physics in medicine and biology"}],"part":{"issue":"2","text":"62(2017), 2, Seite 573-595","extent":"23","pages":"573-595","volume":"62","year":"2017"},"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"recId":"269016163","physDesc":[{"extent":"Online-Ressource"}],"disp":"3D dosimetric validation of motion compensation concepts in radiotherapy using an anthropomorphic dynamic lung phantomPhysics in medicine and biology"}],"person":[{"family":"Mann","role":"aut","given":"Philipp","display":"Mann, Philipp"},{"display":"Witte, Maximilian","family":"Witte","role":"aut","given":"Maximilian"},{"given":"Torsten","role":"aut","family":"Moser","display":"Moser, Torsten"},{"role":"aut","given":"Clemens","family":"Lang","display":"Lang, Clemens"},{"display":"Runz, Armin","family":"Runz","given":"Armin","role":"aut"},{"display":"Johnen, Wibke","family":"Johnen","given":"Wibke","role":"aut"},{"role":"aut","given":"Jürgen","family":"Biederer","display":"Biederer, Jürgen"},{"display":"Karger, Christian","family":"Karger","role":"aut","given":"Christian"}],"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"2017"}],"title":[{"title":"3D dosimetric validation of motion compensation concepts in radiotherapy using an anthropomorphic dynamic lung phantom","title_sort":"3D dosimetric validation of motion compensation concepts in radiotherapy using an anthropomorphic dynamic lung phantom"}],"note":["Published 29 December 2016","Gesehen am 14.09.2018"],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1580994067","physDesc":[{"extent":"23 S."}]} 
SRT |a MANNPHILIP3DDOSIMETR2017