Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy

ObjectiveTo achieve the fastest possible workflow in ischaemic stroke, we developed a CT/C-arm system, which allows imaging and endovascular treatment on the same patient table.MethodsThis prospective, monocentric trial was conducted between October 2014 and August 2016. Patients received stroke ima...

Full description

Saved in:
Bibliographic Details
Main Authors: Pfaff, Johannes (Author) , Schönenberger, Silvia (Author) , Herweh, Christian (Author) , Pham, Mirko (Author) , Nagel, Simon (Author) , Ringleb, Peter A. (Author) , Heiland, Sabine (Author) , Bendszus, Martin (Author) , Möhlenbruch, Markus Alfred (Author)
Format: Article (Journal)
Language:English
Published: 17 February 2017
In: European radiology
Year: 2017, Volume: 27, Issue: 9, Pages: 3966-3972
ISSN:1432-1084
DOI:10.1007/s00330-017-4762-7
Online Access:Verlag, Volltext: http://dx.doi.org/10.1007/s00330-017-4762-7
Verlag, Volltext: https://doi.org/10.1007/s00330-017-4762-7
Get full text
Author Notes:Johannes Pfaff, Silvia Schönenberger, Christian Herweh, Mirko Pham, Simon Nagel, Peter Arthur Ringleb, Sabine Heiland, Martin Bendszus, Markus Alfred Möhlenbruch

MARC

LEADER 00000caa a2200000 c 4500
001 1581037643
003 DE-627
005 20220815012406.0
007 cr uuu---uuuuu
008 180917s2017 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00330-017-4762-7  |2 doi 
035 |a (DE-627)1581037643 
035 |a (DE-576)511037643 
035 |a (DE-599)BSZ511037643 
035 |a (OCoLC)1341018698 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Pfaff, Johannes  |d 1983-  |e VerfasserIn  |0 (DE-588)14226718X  |0 (DE-627)704185598  |0 (DE-576)329375318  |4 aut 
245 1 0 |a Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy  |c Johannes Pfaff, Silvia Schönenberger, Christian Herweh, Mirko Pham, Simon Nagel, Peter Arthur Ringleb, Sabine Heiland, Martin Bendszus, Markus Alfred Möhlenbruch 
264 1 |c 17 February 2017 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 17.09.2018 
520 |a ObjectiveTo achieve the fastest possible workflow in ischaemic stroke, we developed a CT/C-arm system, which allows imaging and endovascular treatment on the same patient table.MethodsThis prospective, monocentric trial was conducted between October 2014 and August 2016. Patients received stroke imaging and mechanical thrombectomy under general anaesthesia (GA) or conscious sedation (CS) using our combined setup comprising a CT-scanner and a mobile C-arm X-ray device. Primary endpoint was time between stroke imaging and groin puncture. We compared periprocedural workflow and procedure times with the literature and a matched patient cohort treated with a biplane angiographic system before installation of the CT/C-arm system.ResultsIn 50 patients with acute ischaemic stroke due to large-vessel occlusion in the anterior circulation, comparable recanalization rates were achieved by using the CT/C-arm setup (TICI2b-3:CT/C-arm-GA: 85.7%; CT/C-arm-CS: 90.9%; Angiosuite: 78.6%; p = 0.269) without increasing periprocedural complications. Elimination of patient transport resulted in a significant reduction of the time between stroke imaging and groin puncture: median, min (IQR): CT/C-arm-GA: 43 (35-52); CT/C-arm-CS: 39 (28-49); Angiosuite: 64 (48-74); p < 0.0001.ConclusionThe combined CT/C-arm system allows comparable recanalization rates as a biplane angiographic system and accelerates the start of the endovascular stroke treatment. Key Points • The CT/C-arm setup reduces median time from stroke imaging to groin puncture.• Mechanical thrombectomy using a C-arm device is feasible without increasing peri-interventional complications.• The CT/C-arm setup might be a valuable fallback solution for emergency procedures.• The CT/C-arm setup allows immediate control CT images during and after treatment. 
650 4 |a Acute ischaemic stroke 
650 4 |a Combined CT/C-arm system 
650 4 |a Mechanical thrombectomy 
650 4 |a Periprocedural workflow 
650 4 |a Procedure times 
700 1 |a Schönenberger, Silvia  |d 1980-  |e VerfasserIn  |0 (DE-588)13925627X  |0 (DE-627)703267191  |0 (DE-576)310920094  |4 aut 
700 1 |a Herweh, Christian  |d 1974-  |e VerfasserIn  |0 (DE-588)129014567  |0 (DE-627)387770038  |0 (DE-576)297447394  |4 aut 
700 1 |a Pham, Mirko  |d 1978-  |e VerfasserIn  |0 (DE-588)132435241  |0 (DE-627)522697763  |0 (DE-576)252667034  |4 aut 
700 1 |a Nagel, Simon  |d 1974-  |e VerfasserIn  |0 (DE-588)129036072  |0 (DE-627)38788775X  |0 (DE-576)297460218  |4 aut 
700 1 |a Ringleb, Peter A.  |e VerfasserIn  |0 (DE-588)1032676175  |0 (DE-627)73863364X  |0 (DE-576)172917743  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Möhlenbruch, Markus Alfred  |d 1979-  |e VerfasserIn  |0 (DE-588)137693591  |0 (DE-627)594845041  |0 (DE-576)304845655  |4 aut 
773 0 8 |i Enthalten in  |t European radiology  |d Berlin : Springer, 1991  |g 27(2017), 9, Seite 3966-3972  |h Online-Ressource  |w (DE-627)268757526  |w (DE-600)1472718-3  |w (DE-576)103868070  |x 1432-1084  |7 nnas  |a Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy 
773 1 8 |g volume:27  |g year:2017  |g number:9  |g pages:3966-3972  |g extent:7  |a Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy 
856 4 0 |u http://dx.doi.org/10.1007/s00330-017-4762-7  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://doi.org/10.1007/s00330-017-4762-7  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180917 
993 |a Article 
994 |a 2017 
998 |g 137693591  |a Möhlenbruch, Markus Alfred  |m 137693591:Möhlenbruch, Markus Alfred  |d 910000  |d 911100  |e 910000PM137693591  |e 911100PM137693591  |k 0/910000/  |k 1/910000/911100/  |p 9  |y j 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 8 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 60000  |d 62700  |e 60000PH106732626X  |e 62700PH106732626X  |k 0/60000/  |k 1/60000/62700/  |p 7 
998 |g 1032676175  |a Ringleb, Peter A.  |m 1032676175:Ringleb, Peter A.  |d 910000  |d 911100  |e 910000PR1032676175  |e 911100PR1032676175  |k 0/910000/  |k 1/910000/911100/  |p 6 
998 |g 129036072  |a Nagel, Simon  |m 129036072:Nagel, Simon  |d 910000  |d 911100  |e 910000PN129036072  |e 911100PN129036072  |k 0/910000/  |k 1/910000/911100/  |p 5 
998 |g 132435241  |a Pham, Mirko  |m 132435241:Pham, Mirko  |d 910000  |d 911100  |e 910000PP132435241  |e 911100PP132435241  |k 0/910000/  |k 1/910000/911100/  |p 4 
998 |g 129014567  |a Herweh, Christian  |m 129014567:Herweh, Christian  |d 910000  |d 911100  |e 910000PH129014567  |e 911100PH129014567  |k 0/910000/  |k 1/910000/911100/  |p 3 
998 |g 13925627X  |a Schönenberger, Silvia  |m 13925627X:Schönenberger, Silvia  |d 910000  |d 911100  |e 910000PS13925627X  |e 911100PS13925627X  |k 0/910000/  |k 1/910000/911100/  |p 2 
998 |g 14226718X  |a Pfaff, Johannes  |m 14226718X:Pfaff, Johannes  |d 910000  |d 911100  |e 910000PP14226718X  |e 911100PP14226718X  |k 0/910000/  |k 1/910000/911100/  |p 1  |x j 
999 |a KXP-PPN1581037643  |e 3025728175 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1581037643"],"doi":["10.1007/s00330-017-4762-7"]},"title":[{"title":"Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy","title_sort":"Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy"}],"recId":"1581037643","note":["Gesehen am 17.09.2018"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"17 February 2017"}],"person":[{"given":"Johannes","role":"aut","display":"Pfaff, Johannes","family":"Pfaff","roleDisplay":"VerfasserIn"},{"given":"Silvia","role":"aut","display":"Schönenberger, Silvia","family":"Schönenberger","roleDisplay":"VerfasserIn"},{"family":"Herweh","roleDisplay":"VerfasserIn","role":"aut","display":"Herweh, Christian","given":"Christian"},{"family":"Pham","roleDisplay":"VerfasserIn","role":"aut","display":"Pham, Mirko","given":"Mirko"},{"display":"Nagel, Simon","role":"aut","given":"Simon","roleDisplay":"VerfasserIn","family":"Nagel"},{"family":"Ringleb","roleDisplay":"VerfasserIn","display":"Ringleb, Peter A.","role":"aut","given":"Peter A."},{"family":"Heiland","roleDisplay":"VerfasserIn","given":"Sabine","role":"aut","display":"Heiland, Sabine"},{"given":"Martin","role":"aut","display":"Bendszus, Martin","family":"Bendszus","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Möhlenbruch","role":"aut","display":"Möhlenbruch, Markus Alfred","given":"Markus Alfred"}],"name":{"displayForm":["Johannes Pfaff, Silvia Schönenberger, Christian Herweh, Mirko Pham, Simon Nagel, Peter Arthur Ringleb, Sabine Heiland, Martin Bendszus, Markus Alfred Möhlenbruch"]},"physDesc":[{"extent":"7 S."}],"relHost":[{"pubHistory":["1.1991 -"],"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}],"corporate":[{"roleDisplay":"Herausgebendes Organ","role":"isb","display":"European Association of Radiology"}],"recId":"268757526","id":{"issn":["1432-1084","1613-3757"],"zdb":["1472718-3"],"eki":["268757526"]},"title":[{"subtitle":"official organ of the European Association of Radiology","title":"European radiology","title_sort":"European radiology"}],"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"disp":"Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomyEuropean radiology","part":{"extent":"7","year":"2017","pages":"3966-3972","text":"27(2017), 9, Seite 3966-3972","issue":"9","volume":"27"},"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"],"origin":[{"dateIssuedDisp":"1991-","publisherPlace":"Berlin ; Heidelberg","dateIssuedKey":"1991","publisher":"Springer"}],"type":{"bibl":"periodical","media":"Online-Ressource"}}]} 
SRT |a PFAFFJOHANINFLUENCEO1720