Use of the pCONus as an adjunct to coil embolization of acutely ruptured aneurysms

Introduction: Coil embolization of ruptured aneurysms has become the standard treatment in many situations. However, certain aneurysm morphologies pose technical difficulties and may require the use of adjunctive devices. Objective: To present our experience with the pCONus, a new neck bridging devi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Aguilar Pérez, Marta (VerfasserIn) , Bäzner, Hansjörg (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2017
In: Journal of neuroInterventional surgery
Year: 2016, Jahrgang: 9, Heft: 1, Pages: 39-44
ISSN:1759-8486
DOI:10.1136/neurintsurg-2016-012508
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1136/neurintsurg-2016-012508
Verlag, Volltext: https://jnis-bmj-com.ezproxy.medma.uni-heidelberg.de/content/9/1/39
Volltext
Verfasserangaben:M. Aguilar Pérez, P. Bhogal, R. Martinez Moreno, C. Wendl, H. Bäzner, O. Ganslandt, H. Henkes

MARC

LEADER 00000caa a2200000 c 4500
001 1581040814
003 DE-627
005 20220815012550.0
007 cr uuu---uuuuu
008 180917r20172016xx |||||o 00| ||eng c
024 7 |a 10.1136/neurintsurg-2016-012508  |2 doi 
035 |a (DE-627)1581040814 
035 |a (DE-576)511040814 
035 |a (DE-599)BSZ511040814 
035 |a (OCoLC)1341018602 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Aguilar Pérez, Marta  |d 1981-  |e VerfasserIn  |0 (DE-588)1077257465  |0 (DE-627)836178831  |0 (DE-576)446143464  |4 aut 
245 1 0 |a Use of the pCONus as an adjunct to coil embolization of acutely ruptured aneurysms  |c M. Aguilar Pérez, P. Bhogal, R. Martinez Moreno, C. Wendl, H. Bäzner, O. Ganslandt, H. Henkes 
264 1 |c 2017 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 17.09.2018 
500 |a Published online first 13 July 2016 
520 |a Introduction: Coil embolization of ruptured aneurysms has become the standard treatment in many situations. However, certain aneurysm morphologies pose technical difficulties and may require the use of adjunctive devices. Objective: To present our experience with the pCONus, a new neck bridging device, as an adjunct to coil embolization for acutely ruptured aneurysms and discuss the technical success, angiographic and clinical outcomes. Methods: We conducted a retrospective review of our database of prospectively collected data to identify all patients who presented with acute subarachnoid hemorrhage that required adjunctive treatment with the pCONus in the acute stage. We searched the database between April 2011 and April 2016. Results: 21 patients were identified (13 male, 8 female) with an average age of 54.6 years (range 31-73). 8 aneurysms were located at the basilar artery tip, 7 at the anterior communicating artery, 4 at the middle cerebral artery bifurcation, 1 pericallosal, and 1 basilar fenestration. 61.8% patients achieved modified Raymond-Roy classification I or II at immediate angiography, with 75% of patients having completely occluded aneurysms or stable appearance at initial follow-up. There were no repeat aneurysmal ruptures and two device-related complications (no permanent morbidity). Four patients in our cohort died. Conclusions: Use of the pCONus is safe and effective in patients with acutely ruptured aneurysms and carries a high rate of technical success. 
534 |c 2016 
650 4 |a Aneurysm 
650 4 |a Stent 
650 4 |a Subarachnoid 
700 1 |a Bäzner, Hansjörg  |e VerfasserIn  |0 (DE-588)1031161775  |0 (DE-627)735747873  |0 (DE-576)174519311  |4 aut 
773 0 8 |i Enthalten in  |t Journal of neuroInterventional surgery  |d London : BMJ Journals, 2009  |g 9(2017), 1, Seite 39-44  |h Online-Ressource  |w (DE-627)605217548  |w (DE-600)2506028-4  |w (DE-576)308906721  |x 1759-8486  |7 nnas  |a Use of the pCONus as an adjunct to coil embolization of acutely ruptured aneurysms 
773 1 8 |g volume:9  |g year:2017  |g number:1  |g pages:39-44  |g extent:7  |a Use of the pCONus as an adjunct to coil embolization of acutely ruptured aneurysms 
856 4 0 |u http://dx.doi.org/10.1136/neurintsurg-2016-012508  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://jnis-bmj-com.ezproxy.medma.uni-heidelberg.de/content/9/1/39  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180917 
993 |a Article 
994 |a 2017 
998 |g 1031161775  |a Bäzner, Hansjörg  |m 1031161775:Bäzner, Hansjörg  |d 60000  |e 60000PB1031161775  |k 0/60000/  |p 5 
999 |a KXP-PPN1581040814  |e 3025732466 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Use of the pCONus as an adjunct to coil embolization of acutely ruptured aneurysms","title_sort":"Use of the pCONus as an adjunct to coil embolization of acutely ruptured aneurysms"}],"person":[{"family":"Aguilar Pérez","given":"Marta","display":"Aguilar Pérez, Marta","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Hansjörg","family":"Bäzner","role":"aut","roleDisplay":"VerfasserIn","display":"Bäzner, Hansjörg"}],"note":["Gesehen am 17.09.2018","Published online first 13 July 2016"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"recId":"1581040814","origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"2017"}],"id":{"doi":["10.1136/neurintsurg-2016-012508"],"eki":["1581040814"]},"name":{"displayForm":["M. Aguilar Pérez, P. Bhogal, R. Martinez Moreno, C. Wendl, H. Bäzner, O. Ganslandt, H. Henkes"]},"physDesc":[{"extent":"7 S."}],"relHost":[{"title":[{"title":"Journal of neuroInterventional surgery","subtitle":"JNIS ; the journal of the Society of NeuroInterventional Surgery","title_sort":"Journal of neuroInterventional surgery"}],"disp":"Use of the pCONus as an adjunct to coil embolization of acutely ruptured aneurysmsJournal of neuroInterventional surgery","type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 03.01.11"],"language":["eng"],"recId":"605217548","pubHistory":["1.2009 -"],"part":{"year":"2017","pages":"39-44","issue":"1","volume":"9","text":"9(2017), 1, Seite 39-44","extent":"7"},"titleAlt":[{"title":"JNIS"}],"origin":[{"dateIssuedDisp":"2009-","dateIssuedKey":"2009","publisher":"BMJ Journals","publisherPlace":"London"}],"id":{"issn":["1759-8486"],"zdb":["2506028-4"],"eki":["605217548"]},"physDesc":[{"extent":"Online-Ressource"}]}]} 
SRT |a AGUILARPERUSEOFTHEPC2017