Comparison of immediately loaded flapless-placed one-piece implants and flapped-placed conventionally loaded two-piece implants, both fitted with all-ceramic single crowns, in the posterior mandible: 3-year results from a randomised controlled pilot trial

Purpose: To compare outcomes for immediately loaded one-piece implants (OPI), placed flapless, and conventionally loaded two-piece implants (TPI), placed after two-stage flapped surgery. Materials and methods: Thirty-eight participants were randomised to receive either one OPI (19 participants, OPI gr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bömicke, Wolfgang (VerfasserIn) , Gabbert, Olaf (VerfasserIn) , Koob, Andreas (VerfasserIn) , Krisam, Johannes (VerfasserIn) , Rammelsberg, Peter (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 29.05.2017
In: European journal of oral implantology
Year: 2017, Jahrgang: 10, Heft: 2, Pages: 179-195
ISSN:1756-2414
Online-Zugang:Verlag, Volltext: https://www.quintessence-publishing.com/deu/en/journal/international-journal-of-oral-implantology/2017/02
Volltext
Verfasserangaben:Wolfgang Bömicke, Olaf Gabbert, Andreas Koob, Johannes Krisam, Peter Rammelsberg

MARC

LEADER 00000caa a2200000 c 4500
001 1581072872
003 DE-627
005 20220815012947.0
007 cr uuu---uuuuu
008 180918s2017 xx |||||o 00| ||eng c
035 |a (DE-627)1581072872 
035 |a (DE-576)511072872 
035 |a (DE-599)BSZ511072872 
035 |a (OCoLC)1341018906 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Bömicke, Wolfgang  |d 1981-  |e VerfasserIn  |0 (DE-588)1015022146  |0 (DE-627)668338792  |0 (DE-576)349947651  |4 aut 
245 1 0 |a Comparison of immediately loaded flapless-placed one-piece implants and flapped-placed conventionally loaded two-piece implants, both fitted with all-ceramic single crowns, in the posterior mandible  |b 3-year results from a randomised controlled pilot trial  |c Wolfgang Bömicke, Olaf Gabbert, Andreas Koob, Johannes Krisam, Peter Rammelsberg 
246 3 0 |a three-year 
264 1 |c 29.05.2017 
300 |a 17 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 18.09.2018 
500 |a Keine DOI vorhanden 
520 |a Purpose: To compare outcomes for immediately loaded one-piece implants (OPI), placed flapless, and conventionally loaded two-piece implants (TPI), placed after two-stage flapped surgery. Materials and methods: Thirty-eight participants were randomised to receive either one OPI (19 participants, OPI group) or one TPI (19 participants, TPI group) inserted in the posterior mandible with a torque of at least 35 Ncm according to a parallel group design. OPI were immediately loaded with non-occluding temporary crowns. After 3 months, TPI were exposed and implants in both groups were occlusally loaded with zirconia crowns. Outcome measures were implant failure, prosthesis failure, any complication and changes of probing pocket depth (PPD), plaque index (PI), gingiva index (GI), and peri-implant marginal bone level, recorded by unblinded assessors. Results: Three years after occlusal loading, three participants dropped out from the TPI group. There were no statistically significant differences between the groups with regard to participants with implant failure (OPI group 1/19; TPI group 0/16; difference in proportions (DIP), −5.3%; 95% confidence interval (CI) −15.3 to 4.8; P = 1.000), prosthesis failure (OPI group 3/19, TPI group 5/16; DIP, 15.5%; 95% CI −12.6 to 43.5; P = 0.424), any complication (OPI group 6/19, TPI group 5/16; DIP, −0.3%; 95% CI −31.2 to 30.5; P = 1.000), or changes of PPD (P =0.174), PI (P = 0.222), or GI (P = 0.415). Veneer chipping accounted for most prosthesis failures and complications. On average OPI and TPI lost 1.34 mm and 0.67 mm of marginal bone, respectively, the difference between groups being statistically significant (mean difference, 0.66 mm; 95% CI −0.02 to 1.34; P = 0.024) in favour of TPI implants. Conclusions: Both implant procedures might be viable in the short term, but statistically significantly more bone loss might be indicative of future problems with OPI. Because of the high incidence of chipping, veneered zirconia crowns cannot be recommended on posterior implants. 
700 1 |a Gabbert, Olaf  |d 1966-  |e VerfasserIn  |0 (DE-588)133292517  |0 (DE-627)539938289  |0 (DE-576)29975314X  |4 aut 
700 1 |a Koob, Andreas  |d 1974-  |e VerfasserIn  |0 (DE-588)124251137  |0 (DE-627)085737542  |0 (DE-576)294088342  |4 aut 
700 1 |a Krisam, Johannes  |d 1986-  |e VerfasserIn  |0 (DE-588)1016031343  |0 (DE-627)705475034  |0 (DE-576)351438696  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
773 0 8 |i Enthalten in  |t European journal of oral implantology  |d Berlin : Quintessenz Verlags-GmbH, 2008  |g 10(2017), 2, Seite 179-195  |h Online-Ressource  |w (DE-627)56658557X  |w (DE-600)2426048-4  |w (DE-576)494390972  |x 1756-2414  |7 nnas  |a Comparison of immediately loaded flapless-placed one-piece implants and flapped-placed conventionally loaded two-piece implants, both fitted with all-ceramic single crowns, in the posterior mandible 3-year results from a randomised controlled pilot trial 
773 1 8 |g volume:10  |g year:2017  |g number:2  |g pages:179-195  |g extent:17  |a Comparison of immediately loaded flapless-placed one-piece implants and flapped-placed conventionally loaded two-piece implants, both fitted with all-ceramic single crowns, in the posterior mandible 3-year results from a randomised controlled pilot trial 
856 4 0 |u https://www.quintessence-publishing.com/deu/en/journal/international-journal-of-oral-implantology/2017/02  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180918 
993 |a Article 
994 |a 2017 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 5  |y j 
998 |g 1016031343  |a Krisam, Johannes  |m 1016031343:Krisam, Johannes  |d 910000  |d 999701  |e 910000PK1016031343  |e 999701PK1016031343  |k 0/910000/  |k 1/910000/999701/  |p 4 
998 |g 124251137  |a Koob, Andreas  |m 124251137:Koob, Andreas  |d 910000  |d 910800  |e 910000PK124251137  |e 910800PK124251137  |k 0/910000/  |k 1/910000/910800/  |p 3 
998 |g 133292517  |a Gabbert, Olaf  |m 133292517:Gabbert, Olaf  |d 910000  |d 910800  |e 910000PG133292517  |e 910800PG133292517  |k 0/910000/  |k 1/910000/910800/  |p 2 
998 |g 1015022146  |a Bömicke, Wolfgang  |m 1015022146:Bömicke, Wolfgang  |d 910000  |d 910800  |e 910000PB1015022146  |e 910800PB1015022146  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1581072872  |e 3025787473 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Wolfgang Bömicke, Olaf Gabbert, Andreas Koob, Johannes Krisam, Peter Rammelsberg"]},"note":["Gesehen am 18.09.2018","Keine DOI vorhanden"],"recId":"1581072872","origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"29.05.2017"}],"id":{"eki":["1581072872"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"person":[{"role":"aut","given":"Wolfgang","display":"Bömicke, Wolfgang","family":"Bömicke"},{"role":"aut","given":"Olaf","family":"Gabbert","display":"Gabbert, Olaf"},{"family":"Koob","display":"Koob, Andreas","given":"Andreas","role":"aut"},{"role":"aut","display":"Krisam, Johannes","family":"Krisam","given":"Johannes"},{"given":"Peter","display":"Rammelsberg, Peter","family":"Rammelsberg","role":"aut"}],"physDesc":[{"extent":"17 S."}],"title":[{"title":"Comparison of immediately loaded flapless-placed one-piece implants and flapped-placed conventionally loaded two-piece implants, both fitted with all-ceramic single crowns, in the posterior mandible","subtitle":"3-year results from a randomised controlled pilot trial","title_sort":"Comparison of immediately loaded flapless-placed one-piece implants and flapped-placed conventionally loaded two-piece implants, both fitted with all-ceramic single crowns, in the posterior mandible"}],"relHost":[{"disp":"Comparison of immediately loaded flapless-placed one-piece implants and flapped-placed conventionally loaded two-piece implants, both fitted with all-ceramic single crowns, in the posterior mandible 3-year results from a randomised controlled pilot trialEuropean journal of oral implantology","pubHistory":["1.2008-11, no. 4 (2018)"],"recId":"56658557X","id":{"zdb":["2426048-4"],"issn":["1756-2414"],"eki":["56658557X"]},"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2008","publisher":"Quintessenz Verlags-GmbH","publisherPlace":"Berlin","dateIssuedDisp":"2008-2018"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"European journal of oral implantology","title":"European journal of oral implantology","subtitle":"official publication of the British Society of Oral Implantology (BSOI) and the Dutch Society of Oral Implantology (NVOI)"}],"part":{"year":"2017","extent":"17","issue":"2","volume":"10","pages":"179-195","text":"10(2017), 2, Seite 179-195"}}]} 
SRT |a BOEMICKEWOCOMPARISON2905