Femoral rotation in total knee arthroplasty: a comparison of patient individualized jigs with gap balancing in relation to anatomic landmarks
Purpose The purpose of our study was to compare the accuracy of the rotational position of the femoral component in total knee arthroplasty aligned with patient individualized jigs (PSJ) to a gap balancing technique (GBT).MethodsA consecutive series of 21 osteoarthritic patients were treated with 22...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2017
|
| In: |
Knee surgery, sports traumatology, arthroscopy
Year: 2015, Jahrgang: 25, Heft: 6, Pages: 1712-1719 |
| ISSN: | 1433-7347 |
| DOI: | 10.1007/s00167-015-3836-9 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1007/s00167-015-3836-9 |
| Verfasserangaben: | W. Fitz, S. Jäger, J.S. Rieger, E. Seebach, R.G. Bitsch |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1581082827 | ||
| 003 | DE-627 | ||
| 005 | 20220815013231.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180918r20172015xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00167-015-3836-9 |2 doi | |
| 035 | |a (DE-627)1581082827 | ||
| 035 | |a (DE-576)511082827 | ||
| 035 | |a (DE-599)BSZ511082827 | ||
| 035 | |a (OCoLC)1341018471 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Fitz, Wolfgang |e VerfasserIn |0 (DE-588)1167282299 |0 (DE-627)1030949743 |0 (DE-576)511082819 |4 aut | |
| 245 | 1 | 0 | |a Femoral rotation in total knee arthroplasty |b a comparison of patient individualized jigs with gap balancing in relation to anatomic landmarks |c W. Fitz, S. Jäger, J.S. Rieger, E. Seebach, R.G. Bitsch |
| 264 | 1 | |c 2017 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Published online: 24 October 2015 | ||
| 500 | |a Gesehen am 21.08.2019 | ||
| 520 | |a Purpose The purpose of our study was to compare the accuracy of the rotational position of the femoral component in total knee arthroplasty aligned with patient individualized jigs (PSJ) to a gap balancing technique (GBT).MethodsA consecutive series of 21 osteoarthritic patients were treated with 22 cruciate-retaining total knee prostheses. During surgery, the rotation of the femoral component pinholes was recorded for all knees using PSJ and GBT and transferred to computer tomograms (CT). The rotational differences between PSJ and GBT relative to the transepicondylar axis were analysed.ResultsThe medium rotation of the femoral component pinholes was 1.3° ± 5.1° (min = −6.3°; max = 14.4°) for PSJ and 0.1 ± 1.4° (min = −1.6°; max = 3.4°) for GBT. Outliers of more than 3° were found more frequently with PSJ in 12 cases but only in one for GBT.ConclusionBased on our study, we would not recommend relying intra-operatively solely on the CT-based PSJ without the option to adjust or control femoral rotation.Level of evidenceII. | ||
| 534 | |c 2015 | ||
| 650 | 4 | |a Femoral rotation | |
| 650 | 4 | |a Gap balancing | |
| 650 | 4 | |a Patient-specific jigs | |
| 650 | 4 | |a Total knee arthroplasty | |
| 650 | 4 | |a Transepicondylar axis | |
| 700 | 1 | |a Jäger, Sebastian |d 1975- |e VerfasserIn |0 (DE-588)1059313731 |0 (DE-627)79828238X |0 (DE-576)415306647 |4 aut | |
| 700 | 1 | |a Rieger, Johannes Sebastian |d 1984- |e VerfasserIn |0 (DE-588)111862887X |0 (DE-627)872125459 |0 (DE-576)479541531 |4 aut | |
| 700 | 1 | |a Seebach, Elisabeth |d 1984- |e VerfasserIn |0 (DE-588)1075771412 |0 (DE-627)833831488 |0 (DE-576)444648844 |4 aut | |
| 700 | 1 | |a Bitsch, Rudi G. |d 1970- |e VerfasserIn |0 (DE-588)131490060 |0 (DE-627)50981378X |0 (DE-576)298541726 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Knee surgery, sports traumatology, arthroscopy |d Berlin : Springer, 1993 |g 25(2017), 6, Seite 1712-1719 |h Online-Ressource |w (DE-627)268761787 |w (DE-600)1473170-8 |w (DE-576)094425191 |x 1433-7347 |7 nnas |a Femoral rotation in total knee arthroplasty a comparison of patient individualized jigs with gap balancing in relation to anatomic landmarks |
| 773 | 1 | 8 | |g volume:25 |g year:2017 |g number:6 |g pages:1712-1719 |g extent:8 |a Femoral rotation in total knee arthroplasty a comparison of patient individualized jigs with gap balancing in relation to anatomic landmarks |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00167-015-3836-9 |x Verlag |x Resolving-System |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180918 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 131490060 |a Bitsch, Rudi G. |m 131490060:Bitsch, Rudi G. |d 910000 |d 911460 |d 50000 |e 910000PB131490060 |e 911460PB131490060 |e 50000PB131490060 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 5 |y j | ||
| 998 | |g 1075771412 |a Seebach, Elisabeth |m 1075771412:Seebach, Elisabeth |d 910000 |d 911700 |e 910000PS1075771412 |e 911700PS1075771412 |k 0/910000/ |k 1/910000/911700/ |p 4 | ||
| 998 | |g 111862887X |a Rieger, Johannes Sebastian |m 111862887X:Rieger, Johannes Sebastian |d 910000 |d 911460 |e 910000PR111862887X |e 911460PR111862887X |k 0/910000/ |k 1/910000/911460/ |p 3 | ||
| 998 | |g 1059313731 |a Jäger, Sebastian |m 1059313731:Jäger, Sebastian |d 910000 |d 911460 |e 910000PJ1059313731 |e 911460PJ1059313731 |k 0/910000/ |k 1/910000/911460/ |p 2 | ||
| 999 | |a KXP-PPN1581082827 |e 3025801840 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["W. Fitz, S. Jäger, J.S. Rieger, E. Seebach, R.G. Bitsch"]},"person":[{"family":"Fitz","given":"Wolfgang","role":"aut","display":"Fitz, Wolfgang"},{"role":"aut","given":"Sebastian","display":"Jäger, Sebastian","family":"Jäger"},{"role":"aut","given":"Johannes Sebastian","display":"Rieger, Johannes Sebastian","family":"Rieger"},{"family":"Seebach","role":"aut","given":"Elisabeth","display":"Seebach, Elisabeth"},{"display":"Bitsch, Rudi G.","role":"aut","given":"Rudi G.","family":"Bitsch"}],"recId":"1581082827","origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"2017"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"8 S."}],"id":{"doi":["10.1007/s00167-015-3836-9"],"eki":["1581082827"]},"note":["Published online: 24 October 2015","Gesehen am 21.08.2019"],"relHost":[{"titleAlt":[{"title":"KSSTA"},{"title":"official journal of the ESSKA ; organ of ESSKA, European Society of Sports Traumatology, Knee Surgery and Arthroscopy"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"publisherPlace":"Berlin ; Heidelberg ; Berlin ; Heidelberg ; New York, NY","publisher":"Springer ; Springer","dateIssuedDisp":"1993-","dateIssuedKey":"1993"}],"recId":"268761787","physDesc":[{"extent":"Online-Ressource"}],"disp":"Femoral rotation in total knee arthroplasty a comparison of patient individualized jigs with gap balancing in relation to anatomic landmarksKnee surgery, sports traumatology, arthroscopy","id":{"eki":["268761787"],"issn":["1433-7347"],"zdb":["1473170-8"]},"corporate":[{"role":"isb","display":"European Society of Sports Traumatology, Knee Surgery and Arthroscopy"}],"note":["Erscheint unregelmäßig","Gesehen am 26.09.2024","Teils ungezählte Beil.: Supplement"],"title":[{"title_sort":"Knee surgery, sports traumatology, arthroscopy","subtitle":"KSSTA ; official journal of the European Society of Sports Traumatology, Knee Surgery and Arthroscopy (ESSKA)","title":"Knee surgery, sports traumatology, arthroscopy"}],"part":{"volume":"25","text":"25(2017), 6, Seite 1712-1719","year":"2017","issue":"6","pages":"1712-1719","extent":"8"},"language":["eng"],"pubHistory":["1.1993 -"]}],"title":[{"subtitle":"a comparison of patient individualized jigs with gap balancing in relation to anatomic landmarks","title":"Femoral rotation in total knee arthroplasty","title_sort":"Femoral rotation in total knee arthroplasty"}],"language":["eng"]} | ||
| SRT | |a FITZWOLFGAFEMORALROT2017 | ||