Performance assessment and benchmarking of autologous peripheral blood stem cell collection with two different apheresis devices

Background Collection of peripheral blood stem cells (PBSCs) for autologous transplantation is a well-established process. As a new generation of leukapheresis (LP) machines has been launched, measures of benchmarking and quality control need to be defined in order to ensure consistent collection pe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wuchter, Patrick (VerfasserIn) , Hundemer, Michael (VerfasserIn) , Schmitt, Anita (VerfasserIn) , Witzens-Harig, Mathias (VerfasserIn) , Hillengaß, Jens (VerfasserIn) , Goldschmidt, Hartmut (VerfasserIn) , Ho, Anthony Dick (VerfasserIn) , Kriegsmann, Katharina (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2017
In: Transfusion medicine
Year: 2016, Jahrgang: 27, Heft: 1, Pages: 36-42
ISSN:1365-3148
DOI:10.1111/tme.12367
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1111/tme.12367
Verlag, Volltext: https://onlinelibrary-wiley-com.ezproxy.medma.uni-heidelberg.de/doi/abs/10.1111/tme.12367
Volltext
Verfasserangaben:P. Wuchter, M. Hundemer, A. Schmitt, M. Witzens‐Harig, P. Pavel, J. Hillengass, H. Goldschmidt, A.D. Ho and K. Lisenko

MARC

LEADER 00000caa a2200000 c 4500
001 1581265042
003 DE-627
005 20220815020057.0
007 cr uuu---uuuuu
008 180925r20172016xx |||||o 00| ||eng c
024 7 |a 10.1111/tme.12367  |2 doi 
035 |a (DE-627)1581265042 
035 |a (DE-576)511265042 
035 |a (DE-599)BSZ511265042 
035 |a (OCoLC)1341019236 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Wuchter, Patrick  |d 1975-  |e VerfasserIn  |0 (DE-588)123450284  |0 (DE-627)082563624  |0 (DE-576)184642574  |4 aut 
245 1 0 |a Performance assessment and benchmarking of autologous peripheral blood stem cell collection with two different apheresis devices  |c P. Wuchter, M. Hundemer, A. Schmitt, M. Witzens‐Harig, P. Pavel, J. Hillengass, H. Goldschmidt, A.D. Ho and K. Lisenko 
264 1 |c 2017 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.09.2018 
500 |a First published online 11 October 2016 
520 |a Background Collection of peripheral blood stem cells (PBSCs) for autologous transplantation is a well-established process. As a new generation of leukapheresis (LP) machines has been launched, measures of benchmarking and quality control need to be defined in order to ensure consistent collection performance. Objectives The goal of this project was to establish and evaluate a benchmarking system for autologous PBSC collection. Methods This retrospective study evaluated PBSC collection data of 198 patients with symptomatic multiple myeloma in first-line therapy who underwent LP in 2013 and 2014 at our institution. Half the patients in 2014 were assigned randomly to undergo LP with the new Terumo BCT Spectra Optia (Terumo BCT, Garching, Germany), while the COBE Spectra (Terumo BCT) was used in all other cases. In 2014, we implemented a previously described formula for predicting daily CD34+ cell collection. As a benchmark, we developed the performance ratio: collected/predicted CD34+ cells. Results There was no significant difference in the number of collected CD34+ cells, the collection efficiency (collected/processed CD34+ cells) and performance ratio between the two collection devices and between LP procedures in 2013 and 2014. Conclusions We present a comprehensive benchmarking tool that is easy to implement, requires minimal expense and allows specific adjustment of LP parameters for optimisation of LP performance. With this approach, we could confirm the equal efficiency of the two compared apheresis systems. 
534 |c 2016 
650 4 |a apheresis 
650 4 |a apheresis technologies 
650 4 |a peripheral blood stem cells 
650 4 |a quality control 
700 1 |a Hundemer, Michael  |d 1972-  |e VerfasserIn  |0 (DE-588)128390549  |0 (DE-627)372634001  |0 (DE-576)297117998  |4 aut 
700 1 |a Schmitt, Anita  |d 1969-  |e VerfasserIn  |0 (DE-588)141722495  |0 (DE-627)630587752  |0 (DE-576)325593892  |4 aut 
700 1 |a Witzens-Harig, Mathias  |e VerfasserIn  |0 (DE-588)1050736516  |0 (DE-627)784812322  |0 (DE-576)404988970  |4 aut 
700 1 |a Hillengaß, Jens  |d 1974-  |e VerfasserIn  |0 (DE-588)124918549  |0 (DE-627)368073823  |0 (DE-576)294568298  |4 aut 
700 1 |a Goldschmidt, Hartmut  |d 1956-  |e VerfasserIn  |0 (DE-588)102258023X  |0 (DE-627)717003809  |0 (DE-576)365637386  |4 aut 
700 1 |a Ho, Anthony Dick  |d 1948-  |e VerfasserIn  |0 (DE-588)108692477  |0 (DE-627)504904205  |0 (DE-576)19010466X  |4 aut 
700 1 |a Kriegsmann, Katharina  |d 1986-  |e VerfasserIn  |0 (DE-588)1049422449  |0 (DE-627)781924006  |0 (DE-576)40339774X  |4 aut 
773 0 8 |i Enthalten in  |t Transfusion medicine  |d Oxford [u.a.] : Wiley-Blackwell, 1991  |g 27(2017), 1, Seite 36-42  |h Online-Ressource  |w (DE-627)320489981  |w (DE-600)2010901-5  |w (DE-576)091169763  |x 1365-3148  |7 nnas  |a Performance assessment and benchmarking of autologous peripheral blood stem cell collection with two different apheresis devices 
773 1 8 |g volume:27  |g year:2017  |g number:1  |g pages:36-42  |g extent:7  |a Performance assessment and benchmarking of autologous peripheral blood stem cell collection with two different apheresis devices 
856 4 0 |u http://dx.doi.org/10.1111/tme.12367  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary-wiley-com.ezproxy.medma.uni-heidelberg.de/doi/abs/10.1111/tme.12367  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180925 
993 |a Article 
994 |a 2017 
998 |g 1049422449  |a Kriegsmann, Katharina  |m 1049422449:Kriegsmann, Katharina  |d 910000  |d 910100  |e 910000PK1049422449  |e 910100PK1049422449  |k 0/910000/  |k 1/910000/910100/  |p 9  |y j 
998 |g 108692477  |a Ho, Anthony Dick  |m 108692477:Ho, Anthony Dick  |d 910000  |d 910100  |e 910000PH108692477  |e 910100PH108692477  |k 0/910000/  |k 1/910000/910100/  |p 8 
998 |g 102258023X  |a Goldschmidt, Hartmut  |m 102258023X:Goldschmidt, Hartmut  |d 910000  |d 910100  |d 50000  |e 910000PG102258023X  |e 910100PG102258023X  |e 50000PG102258023X  |k 0/910000/  |k 1/910000/910100/  |k 0/50000/  |p 7 
998 |g 124918549  |a Hillengaß, Jens  |m 124918549:Hillengaß, Jens  |d 910000  |d 910100  |e 910000PH124918549  |e 910100PH124918549  |k 0/910000/  |k 1/910000/910100/  |p 6 
998 |g 1050736516  |a Witzens-Harig, Mathias  |m 1050736516:Witzens-Harig, Mathias  |d 910000  |d 910100  |e 910000PW1050736516  |e 910100PW1050736516  |k 0/910000/  |k 1/910000/910100/  |p 4 
998 |g 141722495  |a Schmitt, Anita  |m 141722495:Schmitt, Anita  |d 910000  |d 910100  |e 910000PS141722495  |e 910100PS141722495  |k 0/910000/  |k 1/910000/910100/  |p 3 
998 |g 128390549  |a Hundemer, Michael  |m 128390549:Hundemer, Michael  |d 910000  |d 910100  |e 910000PH128390549  |e 910100PH128390549  |k 0/910000/  |k 1/910000/910100/  |p 2 
998 |g 123450284  |a Wuchter, Patrick  |m 123450284:Wuchter, Patrick  |d 60000  |d 63500  |e 60000PW123450284  |e 63500PW123450284  |k 0/60000/  |k 1/60000/63500/  |p 1  |x j 
999 |a KXP-PPN1581265042  |e 3027110764 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1111/tme.12367"],"eki":["1581265042"]},"name":{"displayForm":["P. Wuchter, M. Hundemer, A. Schmitt, M. Witzens‐Harig, P. Pavel, J. Hillengass, H. Goldschmidt, A.D. Ho and K. Lisenko"]},"physDesc":[{"extent":"7 S."}],"recId":"1581265042","note":["Gesehen am 25.09.2018","First published online 11 October 2016"],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"Performance assessment and benchmarking of autologous peripheral blood stem cell collection with two different apheresis devices","title":"Performance assessment and benchmarking of autologous peripheral blood stem cell collection with two different apheresis devices"}],"person":[{"display":"Wuchter, Patrick","family":"Wuchter","role":"aut","given":"Patrick"},{"display":"Hundemer, Michael","role":"aut","given":"Michael","family":"Hundemer"},{"role":"aut","given":"Anita","family":"Schmitt","display":"Schmitt, Anita"},{"display":"Witzens-Harig, Mathias","role":"aut","given":"Mathias","family":"Witzens-Harig"},{"display":"Hillengaß, Jens","family":"Hillengaß","role":"aut","given":"Jens"},{"family":"Goldschmidt","role":"aut","given":"Hartmut","display":"Goldschmidt, Hartmut"},{"display":"Ho, Anthony Dick","family":"Ho","given":"Anthony Dick","role":"aut"},{"family":"Kriegsmann","role":"aut","given":"Katharina","display":"Kriegsmann, Katharina"}],"relHost":[{"part":{"year":"2017","volume":"27","pages":"36-42","extent":"7","text":"27(2017), 1, Seite 36-42","issue":"1"},"id":{"issn":["1365-3148"],"eki":["320489981"],"doi":["10.1111/(ISSN)1365-3148"],"zdb":["2010901-5"]},"pubHistory":["1.1991 -"],"name":{"displayForm":["publ. for the British Blood Transfusion Society"]},"note":["Gesehen am 28.05.08"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"subtitle":"an international journal","title":"Transfusion medicine","title_sort":"Transfusion medicine"}],"origin":[{"dateIssuedKey":"1991","publisherPlace":"Oxford [u.a.] ; Oxford [u.a.] ; Oxford [u.a.]","dateIssuedDisp":"1991-","publisher":"Wiley-Blackwell ; Blackwell Science ; Blackwell"}],"disp":"Performance assessment and benchmarking of autologous peripheral blood stem cell collection with two different apheresis devicesTransfusion medicine","physDesc":[{"extent":"Online-Ressource"}],"recId":"320489981"}],"origin":[{"dateIssuedDisp":"2017","dateIssuedKey":"2017"}]} 
SRT |a WUCHTERPATPERFORMANC2017