Microwave SQUID multiplexing of metallic magnetic calorimeters: status of multiplexer performance and room-temperature readout electronics development

To our present best knowledge, microwave SQUID multiplexing (μμ\mu MUXing) is the most suitable technique for reading out large-scale low-temperature microcalorimeter arrays that consist of hundreds or thousands of individual pixels which require a large readout bandwidth per pixel. For this reason,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wegner, Mathias (VerfasserIn) , Richter, Daniel Philipp (VerfasserIn) , Ahrens, Felix (VerfasserIn) , Sander, Oliver (VerfasserIn) , Kempf, Sebastian (VerfasserIn) , Weber, Marc (VerfasserIn) , Enss, Christian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 26 February 2018
In: Journal of low temperature physics
Year: 2018, Jahrgang: 193, Heft: 3, Pages: 462-475
ISSN:1573-7357
DOI:10.1007/s10909-018-1878-3
Online-Zugang:Verlag, Volltext: https://doi.org/10.1007/s10909-018-1878-3
Volltext
Verfasserangaben:M. Wegner, N. Karcher, O. Krömer, D. Richter, F. Ahrens, O. Sander, S. Kempf, M. Weber, C. Enss

MARC

LEADER 00000caa a2200000 c 4500
001 1581289790
003 DE-627
005 20220815020522.0
007 cr uuu---uuuuu
008 180925s2018 xx |||||o 00| ||eng c
024 7 |a 10.1007/s10909-018-1878-3  |2 doi 
035 |a (DE-627)1581289790 
035 |a (DE-576)511289790 
035 |a (DE-599)BSZ511289790 
035 |a (OCoLC)1341019034 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Wegner, Mathias  |d 1986-  |e VerfasserIn  |0 (DE-588)1176685597  |0 (DE-627)1047656418  |0 (DE-576)516756893  |4 aut 
245 1 0 |a Microwave SQUID multiplexing of metallic magnetic calorimeters  |b status of multiplexer performance and room-temperature readout electronics development  |c M. Wegner, N. Karcher, O. Krömer, D. Richter, F. Ahrens, O. Sander, S. Kempf, M. Weber, C. Enss 
264 1 |c 26 February 2018 
300 |a 14 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.09.2018 
520 |a To our present best knowledge, microwave SQUID multiplexing (μμ\mu MUXing) is the most suitable technique for reading out large-scale low-temperature microcalorimeter arrays that consist of hundreds or thousands of individual pixels which require a large readout bandwidth per pixel. For this reason, the present readout strategy for metallic magnetic calorimeter (MMC) arrays combining an intrinsic fast signal rise time, an excellent energy resolution, a large energy dynamic range, a quantum efficiency close to 100%100%100\% as well as a highly linear detector response is based on μμ\mu MUXing. Within this paper, we summarize the state of the art in MMC μμ\mu MUXing and discuss the most recent results. This particularly includes the discussion of the performance of a 64-pixel detector array with integrated, on-chip microwave SQUID multiplexer, the progress in flux ramp modulation of MMCs as well as the status of the development of a software-defined radio-based room-temperature electronics which is specifically optimized for MMC readout. 
650 4 |a Flux ramp modulation 
650 4 |a Metallic magnetic calorimeters 
650 4 |a Microwave SQUID multiplexer 
650 4 |a MMC 
650 4 |a Software-defined radio 
700 1 |a Richter, Daniel Philipp  |d 1992-  |e VerfasserIn  |0 (DE-588)115518372X  |0 (DE-627)1016516797  |0 (DE-576)501425225  |4 aut 
700 1 |a Ahrens, Felix  |d 1990-  |e VerfasserIn  |0 (DE-588)112775646X  |0 (DE-627)882210068  |0 (DE-576)485370379  |4 aut 
700 1 |a Sander, Oliver  |e VerfasserIn  |0 (DE-588)1012081397  |0 (DE-627)704830353  |0 (DE-576)341326550  |4 aut 
700 1 |a Kempf, Sebastian  |d 1983-  |e VerfasserIn  |0 (DE-588)1020440449  |0 (DE-627)69122143X  |0 (DE-576)360448690  |4 aut 
700 1 |a Weber, Marc  |e VerfasserIn  |0 (DE-588)1036677060  |0 (DE-627)750757175  |0 (DE-576)385241585  |4 aut 
700 1 |a Enss, Christian  |d 1960-  |e VerfasserIn  |0 (DE-588)1020467878  |0 (DE-627)691227020  |0 (DE-576)360449530  |4 aut 
773 0 8 |i Enthalten in  |t Journal of low temperature physics  |d Dordrecht : Springer Science + Business Media B.V., 1969  |g 193(2018), 3, Seite 462-475  |h Online-Ressource  |w (DE-627)320575411  |w (DE-600)2016984-X  |w (DE-576)094505616  |x 1573-7357  |7 nnas  |a Microwave SQUID multiplexing of metallic magnetic calorimeters status of multiplexer performance and room-temperature readout electronics development 
773 1 8 |g volume:193  |g year:2018  |g number:3  |g pages:462-475  |g extent:14  |a Microwave SQUID multiplexing of metallic magnetic calorimeters status of multiplexer performance and room-temperature readout electronics development 
856 4 0 |u https://doi.org/10.1007/s10909-018-1878-3  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20180925 
993 |a Article 
994 |a 2018 
998 |g 1020467878  |a Enss, Christian  |m 1020467878:Enss, Christian  |d 130000  |d 130700  |d 700000  |d 723000  |e 130000PE1020467878  |e 130700PE1020467878  |e 700000PE1020467878  |e 723000PE1020467878  |k 0/130000/  |k 1/130000/130700/  |k 0/700000/  |k 1/700000/723000/  |p 9  |y j 
998 |g 1036677060  |a Weber, Marc  |m 1036677060:Weber, Marc  |d 700000  |d 723000  |e 700000PW1036677060  |e 723000PW1036677060  |k 0/700000/  |k 1/700000/723000/  |p 8 
998 |g 1020440449  |a Kempf, Sebastian  |m 1020440449:Kempf, Sebastian  |d 130000  |d 130700  |d 700000  |d 723000  |e 130000PK1020440449  |e 130700PK1020440449  |e 700000PK1020440449  |e 723000PK1020440449  |k 0/130000/  |k 1/130000/130700/  |k 0/700000/  |k 1/700000/723000/  |p 7 
998 |g 1012081397  |a Sander, Oliver  |m 1012081397:Sander, Oliver  |d 700000  |d 723000  |e 700000PS1012081397  |e 723000PS1012081397  |k 0/700000/  |k 1/700000/723000/  |p 6 
998 |g 112775646X  |a Ahrens, Felix  |m 112775646X:Ahrens, Felix  |d 130000  |d 130700  |e 130000PA112775646X  |e 130700PA112775646X  |k 0/130000/  |k 1/130000/130700/  |p 5 
998 |g 115518372X  |a Richter, Daniel Philipp  |m 115518372X:Richter, Daniel Philipp  |d 130000  |d 130700  |e 130000PR115518372X  |e 130700PR115518372X  |k 0/130000/  |k 1/130000/130700/  |p 4 
998 |g 1176685597  |a Wegner, Mathias  |m 1176685597:Wegner, Mathias  |d 130000  |d 130700  |e 130000PW1176685597  |e 130700PW1176685597  |k 0/130000/  |k 1/130000/130700/  |p 1  |x j 
999 |a KXP-PPN1581289790  |e 302714989X 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"14 S."}],"person":[{"role":"aut","family":"Wegner","display":"Wegner, Mathias","given":"Mathias"},{"family":"Richter","display":"Richter, Daniel Philipp","given":"Daniel Philipp","role":"aut"},{"display":"Ahrens, Felix","family":"Ahrens","given":"Felix","role":"aut"},{"given":"Oliver","family":"Sander","display":"Sander, Oliver","role":"aut"},{"role":"aut","given":"Sebastian","display":"Kempf, Sebastian","family":"Kempf"},{"family":"Weber","display":"Weber, Marc","given":"Marc","role":"aut"},{"family":"Enss","display":"Enss, Christian","given":"Christian","role":"aut"}],"title":[{"title_sort":"Microwave SQUID multiplexing of metallic magnetic calorimeters","title":"Microwave SQUID multiplexing of metallic magnetic calorimeters","subtitle":"status of multiplexer performance and room-temperature readout electronics development"}],"relHost":[{"note":["Gesehen am 21.10.2020"],"pubHistory":["1.1969 -"],"recId":"320575411","disp":"Microwave SQUID multiplexing of metallic magnetic calorimeters status of multiplexer performance and room-temperature readout electronics developmentJournal of low temperature physics","part":{"issue":"3","year":"2018","extent":"14","pages":"462-475","text":"193(2018), 3, Seite 462-475","volume":"193"},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Journal of low temperature physics","title_sort":"Journal of low temperature physics"}],"language":["eng"],"id":{"issn":["1573-7357"],"zdb":["2016984-X"],"eki":["320575411"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"dateIssuedDisp":"1969-","publisherPlace":"Dordrecht ; New York, NY [u.a.] ; Dordrecht","publisher":"Springer Science + Business Media B.V. ; Plenum Press ; Kluwer Academic Publishers","dateIssuedKey":"1969"}]}],"id":{"eki":["1581289790"],"doi":["10.1007/s10909-018-1878-3"]},"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"26 February 2018"}],"name":{"displayForm":["M. Wegner, N. Karcher, O. Krömer, D. Richter, F. Ahrens, O. Sander, S. Kempf, M. Weber, C. Enss"]},"recId":"1581289790","note":["Gesehen am 25.09.2018"]} 
SRT |a WEGNERMATHMICROWAVES2620