Repositionable self-expanding aortic bioprosthesis

Introduction: Transcatheter aortic valve implantation/replacement (TAVI or TAVR) has been established as a first line therapy in patients with symptomatic severe aortic stenosis (AS) at high or prohibitive surgical risk and as an alternative in elderly patients with intermediate surgical risk. Since...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Gomes Botelho Quintas, Bruna (VerfasserIn) , Katus, Hugo (VerfasserIn) , Bekeredjian, Raffi (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 14 Jun 2017
In: Expert review of medical devices
Year: 2017, Jahrgang: 14, Heft: 7, Pages: 565-576
ISSN:1745-2422
DOI:10.1080/17434440.2017.1338136
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1080/17434440.2017.1338136
Verlag, Volltext: https://doi.org/10.1080/17434440.2017.1338136
Volltext
Verfasserangaben:Bruna Gomes, Hugo A. Katus & Raffi Bekeredjian

MARC

LEADER 00000caa a2200000 c 4500
001 1581488793
003 DE-627
005 20220815023104.0
007 cr uuu---uuuuu
008 181002s2017 xx |||||o 00| ||eng c
024 7 |a 10.1080/17434440.2017.1338136  |2 doi 
035 |a (DE-627)1581488793 
035 |a (DE-576)511488793 
035 |a (DE-599)BSZ511488793 
035 |a (OCoLC)1341019514 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Gomes Botelho Quintas, Bruna  |e VerfasserIn  |0 (DE-588)1160334218  |0 (DE-627)1023489570  |0 (DE-576)505861844  |4 aut 
245 1 0 |a Repositionable self-expanding aortic bioprosthesis  |c Bruna Gomes, Hugo A. Katus & Raffi Bekeredjian 
264 1 |c 14 Jun 2017 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 02.10.2018 
520 |a Introduction: Transcatheter aortic valve implantation/replacement (TAVI or TAVR) has been established as a first line therapy in patients with symptomatic severe aortic stenosis (AS) at high or prohibitive surgical risk and as an alternative in elderly patients with intermediate surgical risk. Since its first-in-human procedure in 2002, the past 15-years have shown rapid developments in TAVI technology with the introduction and further improvement of new transcatheter heart valves (THV).Areas covered: There are currently several THV systems available, based on balloon-expandable, self-expandable or other technologies. Some of these are repositionable and retrievable even after partial or full deployment, potentially reducing the risk of malpositioning. The aim of this review is to describe such repositionable self-expandable THV systems.Expert commentary: Repositionability potentially represents a crucial step towards higher safety and efficacy of TAVI. It is unclear if full self-expandability or a combination of self and mechanical expansion will be more advantageous. 
650 4 |a Aortic stenosis 
650 4 |a bioprosthesis 
650 4 |a repositionable 
650 4 |a retrievable 
650 4 |a self-expanding 
650 4 |a TAVI 
650 4 |a TAVR 
650 4 |a transcatheter 
700 1 |a Katus, Hugo  |d 1951-  |e VerfasserIn  |0 (DE-588)108916618  |0 (DE-627)577155040  |0 (DE-576)289625076  |4 aut 
700 1 |a Bekeredjian, Raffi  |d 1972-  |e VerfasserIn  |0 (DE-588)122088271  |0 (DE-627)705767930  |0 (DE-576)293085781  |4 aut 
773 0 8 |i Enthalten in  |t Expert review of medical devices  |d Abingdon : Taylor & Francis Group, 2004  |g 14(2017), 7, Seite 565-576  |h Online-Ressource  |w (DE-627)471684031  |w (DE-600)2167175-8  |w (DE-576)280458258  |x 1745-2422  |7 nnas  |a Repositionable self-expanding aortic bioprosthesis 
773 1 8 |g volume:14  |g year:2017  |g number:7  |g pages:565-576  |g extent:12  |a Repositionable self-expanding aortic bioprosthesis 
856 4 0 |u http://dx.doi.org/10.1080/17434440.2017.1338136  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://doi.org/10.1080/17434440.2017.1338136  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20181002 
993 |a Article 
994 |a 2017 
998 |g 122088271  |a Bekeredjian, Raffi  |m 122088271:Bekeredjian, Raffi  |d 910000  |d 910100  |e 910000PB122088271  |e 910100PB122088271  |k 0/910000/  |k 1/910000/910100/  |p 3  |y j 
998 |g 108916618  |a Katus, Hugo  |m 108916618:Katus, Hugo  |d 910000  |d 910100  |e 910000PK108916618  |e 910100PK108916618  |k 0/910000/  |k 1/910000/910100/  |p 2 
998 |g 1160334218  |a Gomes Botelho Quintas, Bruna  |m 1160334218:Gomes Botelho Quintas, Bruna  |d 910000  |d 910100  |e 910000PG1160334218  |e 910100PG1160334218  |k 0/910000/  |k 1/910000/910100/  |p 1  |x j 
999 |a KXP-PPN1581488793  |e 3027569406 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1581488793","person":[{"given":"Bruna","display":"Gomes Botelho Quintas, Bruna","role":"aut","family":"Gomes Botelho Quintas"},{"role":"aut","family":"Katus","display":"Katus, Hugo","given":"Hugo"},{"family":"Bekeredjian","role":"aut","display":"Bekeredjian, Raffi","given":"Raffi"}],"note":["Gesehen am 02.10.2018"],"language":["eng"],"name":{"displayForm":["Bruna Gomes, Hugo A. Katus & Raffi Bekeredjian"]},"relHost":[{"note":["Gesehen am 09.09.15"],"pubHistory":["1.2004 -"],"language":["eng"],"part":{"volume":"14","year":"2017","pages":"565-576","extent":"12","issue":"7","text":"14(2017), 7, Seite 565-576"},"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Repositionable self-expanding aortic bioprosthesisExpert review of medical devices","recId":"471684031","origin":[{"publisher":"Taylor & Francis Group ; Future Drugs ; Expert Reviews ; Informa Healthcare","dateIssuedDisp":"2004-","dateIssuedKey":"2004","publisherPlace":"Abingdon ; London ; London ; London"}],"title":[{"title":"Expert review of medical devices","title_sort":"Expert review of medical devices"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["471684031"],"issn":["1745-2422"],"zdb":["2167175-8"]}}],"origin":[{"dateIssuedDisp":"14 Jun 2017","dateIssuedKey":"2017"}],"title":[{"title_sort":"Repositionable self-expanding aortic bioprosthesis","title":"Repositionable self-expanding aortic bioprosthesis"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"12 S."}],"id":{"doi":["10.1080/17434440.2017.1338136"],"eki":["1581488793"]}} 
SRT |a GOMESBOTELREPOSITION1420