Measurements of ion mobility in argon and neon based gas mixtures

As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC Run 3 with a substantial space charge density of positive ions i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Deisting, Alexander (VerfasserIn) , Vranic, Danilo (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 11 February 2017
In: Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2016, Jahrgang: 845, Pages: 215-217
ISSN:1872-9576
DOI:10.1016/j.nima.2016.06.093
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.nima.2016.06.093
Verlag, Volltext: https://linkinghub.elsevier.com/retrieve/pii/S016890021630660X
Volltext
Verfasserangaben:Alexander Deisting, Chilo Garabatos, Alexander Szabo, Danilo Vranic

MARC

LEADER 00000caa a2200000 c 4500
001 1581695047
003 DE-627
005 20220815025411.0
007 cr uuu---uuuuu
008 181009r20172016xx |||||o 00| ||eng c
024 7 |a 10.1016/j.nima.2016.06.093  |2 doi 
035 |a (DE-627)1581695047 
035 |a (DE-576)511695047 
035 |a (DE-599)BSZ511695047 
035 |a (OCoLC)1341019799 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Deisting, Alexander  |d 1989-  |e VerfasserIn  |0 (DE-588)1154513815  |0 (DE-627)1015806686  |0 (DE-576)501055851  |4 aut 
245 1 0 |a Measurements of ion mobility in argon and neon based gas mixtures  |c Alexander Deisting, Chilo Garabatos, Alexander Szabo, Danilo Vranic 
264 1 |c 11 February 2017 
300 |a 3 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 18 June 2016 
500 |a Gesehen am 09.10.2018 
520 |a As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC Run 3 with a substantial space charge density of positive ions in the drift volume. In order to properly simulate such space charges, knowledge of the ion mobility K is necessary. To this end, a small gaseous detector was constructed and the ion mobility of various gas mixtures was measured. To validate the corresponding signal analysis, simulations were performed. 
534 |c 2016 
700 1 |a Vranic, Danilo  |e VerfasserIn  |0 (DE-588)1168676703  |0 (DE-627)1032444916  |0 (DE-576)511696027  |4 aut 
773 0 8 |i Enthalten in  |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment  |d [Amsterdam] : Elsevier, 1984  |g 845(2017), Seite 215-217  |h Online-Ressource  |w (DE-627)266014666  |w (DE-600)1466532-3  |w (DE-576)074959743  |x 1872-9576  |7 nnas  |a Measurements of ion mobility in argon and neon based gas mixtures 
773 1 8 |g volume:845  |g year:2017  |g pages:215-217  |g extent:3  |a Measurements of ion mobility in argon and neon based gas mixtures 
856 4 0 |u http://dx.doi.org/10.1016/j.nima.2016.06.093  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://linkinghub.elsevier.com/retrieve/pii/S016890021630660X  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20181009 
993 |a Article 
994 |a 2017 
998 |g 1168676703  |a Vranic, Danilo  |m 1168676703:Vranic, Danilo  |d 130000  |d 130200  |e 130000PV1168676703  |e 130200PV1168676703  |k 0/130000/  |k 1/130000/130200/  |p 4  |y j 
998 |g 1154513815  |a Deisting, Alexander  |m 1154513815:Deisting, Alexander  |d 130000  |d 130200  |e 130000PD1154513815  |e 130200PD1154513815  |k 0/130000/  |k 1/130000/130200/  |p 1  |x j 
999 |a KXP-PPN1581695047  |e 302826059X 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedDisp":"1994-","publisher":"Elsevier ; North-Holland Publ. Co.","dateIssuedKey":"1994","publisherPlace":"[Amsterdam] ; Amsterdam"}],"id":{"eki":["266014666"],"zdb":["1466532-3"],"issn":["1872-9576"]},"disp":"Measurements of ion mobility in argon and neon based gas mixturesNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 24.05.23"],"recId":"266014666","language":["eng"],"pubHistory":["Nachgewiesen 226.1984 -"],"part":{"extent":"3","text":"845(2017), Seite 215-217","volume":"845","pages":"215-217","year":"2017"},"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"title":[{"partname":"Accelerators, spectrometers, detectors and associated equipment","title_sort":"Nuclear instruments & methods in physics research","subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics","title":"Nuclear instruments & methods in physics research"}]}],"physDesc":[{"extent":"3 S."}],"name":{"displayForm":["Alexander Deisting, Chilo Garabatos, Alexander Szabo, Danilo Vranic"]},"id":{"doi":["10.1016/j.nima.2016.06.093"],"eki":["1581695047"]},"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"11 February 2017"}],"recId":"1581695047","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Available online 18 June 2016","Gesehen am 09.10.2018"],"person":[{"display":"Deisting, Alexander","roleDisplay":"VerfasserIn","role":"aut","family":"Deisting","given":"Alexander"},{"family":"Vranic","given":"Danilo","roleDisplay":"VerfasserIn","display":"Vranic, Danilo","role":"aut"}],"title":[{"title_sort":"Measurements of ion mobility in argon and neon based gas mixtures","title":"Measurements of ion mobility in argon and neon based gas mixtures"}]} 
SRT |a DEISTINGALMEASUREMEN1120