Measurements of ion mobility in argon and neon based gas mixtures
As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC Run 3 with a substantial space charge density of positive ions i...
Gespeichert in:
| Hauptverfasser: | , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
11 February 2017
|
| In: |
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2016, Jahrgang: 845, Pages: 215-217 |
| ISSN: | 1872-9576 |
| DOI: | 10.1016/j.nima.2016.06.093 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1016/j.nima.2016.06.093 Verlag, Volltext: https://linkinghub.elsevier.com/retrieve/pii/S016890021630660X |
| Verfasserangaben: | Alexander Deisting, Chilo Garabatos, Alexander Szabo, Danilo Vranic |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1581695047 | ||
| 003 | DE-627 | ||
| 005 | 20220815025411.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 181009r20172016xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.nima.2016.06.093 |2 doi | |
| 035 | |a (DE-627)1581695047 | ||
| 035 | |a (DE-576)511695047 | ||
| 035 | |a (DE-599)BSZ511695047 | ||
| 035 | |a (OCoLC)1341019799 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Deisting, Alexander |d 1989- |e VerfasserIn |0 (DE-588)1154513815 |0 (DE-627)1015806686 |0 (DE-576)501055851 |4 aut | |
| 245 | 1 | 0 | |a Measurements of ion mobility in argon and neon based gas mixtures |c Alexander Deisting, Chilo Garabatos, Alexander Szabo, Danilo Vranic |
| 264 | 1 | |c 11 February 2017 | |
| 300 | |a 3 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 18 June 2016 | ||
| 500 | |a Gesehen am 09.10.2018 | ||
| 520 | |a As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC Run 3 with a substantial space charge density of positive ions in the drift volume. In order to properly simulate such space charges, knowledge of the ion mobility K is necessary. To this end, a small gaseous detector was constructed and the ion mobility of various gas mixtures was measured. To validate the corresponding signal analysis, simulations were performed. | ||
| 534 | |c 2016 | ||
| 700 | 1 | |a Vranic, Danilo |e VerfasserIn |0 (DE-588)1168676703 |0 (DE-627)1032444916 |0 (DE-576)511696027 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment |d [Amsterdam] : Elsevier, 1984 |g 845(2017), Seite 215-217 |h Online-Ressource |w (DE-627)266014666 |w (DE-600)1466532-3 |w (DE-576)074959743 |x 1872-9576 |7 nnas |a Measurements of ion mobility in argon and neon based gas mixtures |
| 773 | 1 | 8 | |g volume:845 |g year:2017 |g pages:215-217 |g extent:3 |a Measurements of ion mobility in argon and neon based gas mixtures |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.nima.2016.06.093 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://linkinghub.elsevier.com/retrieve/pii/S016890021630660X |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20181009 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 1168676703 |a Vranic, Danilo |m 1168676703:Vranic, Danilo |d 130000 |d 130200 |e 130000PV1168676703 |e 130200PV1168676703 |k 0/130000/ |k 1/130000/130200/ |p 4 |y j | ||
| 998 | |g 1154513815 |a Deisting, Alexander |m 1154513815:Deisting, Alexander |d 130000 |d 130200 |e 130000PD1154513815 |e 130200PD1154513815 |k 0/130000/ |k 1/130000/130200/ |p 1 |x j | ||
| 999 | |a KXP-PPN1581695047 |e 302826059X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedDisp":"1994-","publisher":"Elsevier ; North-Holland Publ. Co.","dateIssuedKey":"1994","publisherPlace":"[Amsterdam] ; Amsterdam"}],"id":{"eki":["266014666"],"zdb":["1466532-3"],"issn":["1872-9576"]},"disp":"Measurements of ion mobility in argon and neon based gas mixturesNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 24.05.23"],"recId":"266014666","language":["eng"],"pubHistory":["Nachgewiesen 226.1984 -"],"part":{"extent":"3","text":"845(2017), Seite 215-217","volume":"845","pages":"215-217","year":"2017"},"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"title":[{"partname":"Accelerators, spectrometers, detectors and associated equipment","title_sort":"Nuclear instruments & methods in physics research","subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics","title":"Nuclear instruments & methods in physics research"}]}],"physDesc":[{"extent":"3 S."}],"name":{"displayForm":["Alexander Deisting, Chilo Garabatos, Alexander Szabo, Danilo Vranic"]},"id":{"doi":["10.1016/j.nima.2016.06.093"],"eki":["1581695047"]},"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"11 February 2017"}],"recId":"1581695047","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Available online 18 June 2016","Gesehen am 09.10.2018"],"person":[{"display":"Deisting, Alexander","roleDisplay":"VerfasserIn","role":"aut","family":"Deisting","given":"Alexander"},{"family":"Vranic","given":"Danilo","roleDisplay":"VerfasserIn","display":"Vranic, Danilo","role":"aut"}],"title":[{"title_sort":"Measurements of ion mobility in argon and neon based gas mixtures","title":"Measurements of ion mobility in argon and neon based gas mixtures"}]} | ||
| SRT | |a DEISTINGALMEASUREMEN1120 | ||