Iterative image reconstruction improves the accuracy of automated plaque burden assessment in coronary CT angiography: a comparison with intravascular ultrasound

Abstract: The purpose of this study was to determine whether use of iterative image reconstruction algorithms improves the accuracy of coronary CT angiography (CCTA) compared with intravascular ultrasound (IVUS) in semiautomated plaque burden assessment. MATERIALS AND METHODS. CCTA and IVUS images o...

Full description

Saved in:
Bibliographic Details
Main Authors: Puchner, Stefan B. (Author) , Kauczor, Hans-Ulrich (Author) , Schlett, Christopher L. (Author)
Format: Article (Journal)
Language:English
Published: April 2017
In: American journal of roentgenology
Year: 2017, Volume: 208, Issue: 4, Pages: 777-784
ISSN:1546-3141
DOI:10.2214/AJR.16.17187
Online Access:Verlag, Volltext: http://dx.doi.org/10.2214/AJR.16.17187
Verlag, Volltext: https://www.ajronline.org/doi/10.2214/AJR.16.17187
Get full text
Author Notes:Stefan B. Puchner, Maros Ferencik, Akiko Maehara, Paul Stolzmann, Shixin Ma, Synho Do, Hans-Ulrich Kauczor, Gary S. Mintz, Udo Hoffmann, Christopher L. Schlett

MARC

LEADER 00000caa a2200000 c 4500
001 1582132135
003 DE-627
005 20220815034439.0
007 cr uuu---uuuuu
008 181019s2017 xx |||||o 00| ||eng c
024 7 |a 10.2214/AJR.16.17187  |2 doi 
035 |a (DE-627)1582132135 
035 |a (DE-576)512132135 
035 |a (DE-599)BSZ512132135 
035 |a (OCoLC)1341020362 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Puchner, Stefan B.  |e VerfasserIn  |0 (DE-588)116945805X  |0 (DE-627)1034661337  |0 (DE-576)512132151  |4 aut 
245 1 0 |a Iterative image reconstruction improves the accuracy of automated plaque burden assessment in coronary CT angiography  |b a comparison with intravascular ultrasound  |c Stefan B. Puchner, Maros Ferencik, Akiko Maehara, Paul Stolzmann, Shixin Ma, Synho Do, Hans-Ulrich Kauczor, Gary S. Mintz, Udo Hoffmann, Christopher L. Schlett 
264 1 |c April 2017 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 19.10.2018 
520 |a Abstract: The purpose of this study was to determine whether use of iterative image reconstruction algorithms improves the accuracy of coronary CT angiography (CCTA) compared with intravascular ultrasound (IVUS) in semiautomated plaque burden assessment. MATERIALS AND METHODS. CCTA and IVUS images of seven coronary arteries were acquired ex vivo. CT images were reconstructed with filtered back projection (FBP) and adaptive statistical (ASIR) and model-based (MBIR) iterative reconstruction algorithms. Cross-sectional images of the arteries were coregistered between CCTA and IVUS in 1-mm increments. In CCTA, fully automated (without manual corrections) and semiautomated (allowing manual corrections of vessel wall boundaries) plaque burden assessments were performed for each of the reconstruction algorithms with commercially available software. In IVUS, plaque burden was measured manually. Agreement between CCTA and IVUS was determined with Pearson correlation. RESULTS. A total of 173 corresponding cross sections were included. The mean plaque burden measured with IVUS was 63.39% ± 10.63%. With CCTA and the fully automated technique, it was 54.90% ± 11.70% with FBP, 53.34% ± 13.11% with ASIR, and 55.35% ± 12.22% with MBIR. With CCTA and the semiautomated technique mean plaque burden was 54.90% ± 11.76%, 53.40% ± 12.85%, 57.09% ± 11.05%. Manual correction of the semiautomated assessments was performed in 39% of all cross sections and improved plaque burden correlation with the IVUS assessment independently of reconstruction algorithm (p < 0.0001). Furthermore, MBIR was superior to FBP and ASIR independently of assessment method (semiautomated, r = 0.59 for FBP, r = 0.52 for ASIR, r = 0.78 for MBIR, all p < 0.001; fully automated, r = 0.40 for FBP, r = 0.37 for ASIR, r = 0.53 for MBIR, all p < 0.001). CONCLUSION. For the quantification of plaque burden with CCTA, MBIR led to better correlation with IVUS than did traditional reconstruction algorithms such as FBP, independently of the use of a fully automated or semiautomated assessment approach. The highest accuracy for quantifying plaque burden with CCTA can be achieved by using MBIR data with semiautomated assessment. 
650 4 |a accuracy 
650 4 |a coronary CT angiography 
650 4 |a coronary plaque burden 
650 4 |a intravascular ultrasound 
650 4 |a iterative image reconstruction algorithms 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Schlett, Christopher L.  |d 1983-  |e VerfasserIn  |0 (DE-588)1022729977  |0 (DE-627)717033945  |0 (DE-576)36586398X  |4 aut 
773 0 8 |i Enthalten in  |t American journal of roentgenology  |d Leesburg, Va. : American Roentgen Ray Society, 1965  |g 208(2017), 4, Seite 777-784  |h Online-Ressource  |w (DE-627)320501086  |w (DE-600)2012224-X  |w (DE-576)094113602  |x 1546-3141  |7 nnas  |a Iterative image reconstruction improves the accuracy of automated plaque burden assessment in coronary CT angiography a comparison with intravascular ultrasound 
773 1 8 |g volume:208  |g year:2017  |g number:4  |g pages:777-784  |g extent:8  |a Iterative image reconstruction improves the accuracy of automated plaque burden assessment in coronary CT angiography a comparison with intravascular ultrasound 
856 4 0 |u http://dx.doi.org/10.2214/AJR.16.17187  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://www.ajronline.org/doi/10.2214/AJR.16.17187  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20181019 
993 |a Article 
994 |a 2017 
998 |g 1022729977  |a Schlett, Christopher L.  |m 1022729977:Schlett, Christopher L.  |d 910000  |d 911400  |e 910000PS1022729977  |e 911400PS1022729977  |k 0/910000/  |k 1/910000/911400/  |p 10  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 910200  |e 910000PK139267123  |e 910200PK139267123  |k 0/910000/  |k 1/910000/910200/  |p 7 
999 |a KXP-PPN1582132135  |e 3029233510 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"pubHistory":["Nachgewiesen 95.1965 -"],"titleAlt":[{"title":"AJR"},{"title":"The American journal of roentgenology, radium therapy and nuclear medicine"}],"name":{"displayForm":["American Roentgen Ray Society"]},"part":{"pages":"777-784","issue":"4","extent":"8","text":"208(2017), 4, Seite 777-784","year":"2017","volume":"208"},"id":{"issn":["1546-3141"],"eki":["320501086"],"zdb":["2012224-X"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"320501086","disp":"Iterative image reconstruction improves the accuracy of automated plaque burden assessment in coronary CT angiography a comparison with intravascular ultrasoundAmerican journal of roentgenology","origin":[{"publisherPlace":"Leesburg, Va. ; Stanford, Calif.","dateIssuedDisp":"[1965?]-","publisher":"American Roentgen Ray Society ; Highwire Press"}],"note":["Gesehen am 27.08.2025","Fortsetzung der Druck-Ausgabe"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"title":[{"subtitle":"AJR","title_sort":"American journal of roentgenology","title":"American journal of roentgenology"}]}],"person":[{"display":"Puchner, Stefan B.","role":"aut","given":"Stefan B.","family":"Puchner"},{"display":"Kauczor, Hans-Ulrich","given":"Hans-Ulrich","role":"aut","family":"Kauczor"},{"family":"Schlett","role":"aut","given":"Christopher L.","display":"Schlett, Christopher L."}],"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"April 2017"}],"note":["Gesehen am 19.10.2018"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title":"Iterative image reconstruction improves the accuracy of automated plaque burden assessment in coronary CT angiography","title_sort":"Iterative image reconstruction improves the accuracy of automated plaque burden assessment in coronary CT angiography","subtitle":"a comparison with intravascular ultrasound"}],"physDesc":[{"extent":"8 S."}],"recId":"1582132135","name":{"displayForm":["Stefan B. Puchner, Maros Ferencik, Akiko Maehara, Paul Stolzmann, Shixin Ma, Synho Do, Hans-Ulrich Kauczor, Gary S. Mintz, Udo Hoffmann, Christopher L. Schlett"]},"id":{"eki":["1582132135"],"doi":["10.2214/AJR.16.17187"]}} 