Comparative Monte Carlo study on the performance of integration- and list-mode detector configurations for carbon ion computed tomography

Ion beam therapy offers the possibility of a highly conformal tumor-dose distribution; however, this technique is extremely sensitive to inaccuracies in the treatment procedures. Ambiguities in the conversion of Hounsfield units of the treatment planning x-ray CT to relative stopping power (RSP) can...

Full description

Saved in:
Bibliographic Details
Main Authors: Meyer, Sebastian (Author) , Magallanes Herńandez, Lorena (Author) , Kopp, Benedikt (Author) , Tessonnier, Thomas (Author) , Parodi, Katia (Author)
Format: Article (Journal)
Language:English
Published: 16 January 2017
In: Physics in medicine and biology
Year: 2017, Volume: 62, Issue: 3, Pages: 1096-1112
ISSN:1361-6560
DOI:10.1088/1361-6560/aa5602
Online Access:Verlag, Volltext: http://dx.doi.org/10.1088/1361-6560/aa5602
Verlag, Volltext: http://stacks.iop.org/0031-9155/62/i=3/a=1096
Get full text
Author Notes:Sebastian Meyer, Chiara Gianoli, Lorena Magallanes, Benedikt Kopp, Thomas Tessonnier, Guillaume Landry, George Dedes, Bernd Voss and Katia Parodi
Description
Summary:Ion beam therapy offers the possibility of a highly conformal tumor-dose distribution; however, this technique is extremely sensitive to inaccuracies in the treatment procedures. Ambiguities in the conversion of Hounsfield units of the treatment planning x-ray CT to relative stopping power (RSP) can cause uncertainties in the estimated ion range of up to several millimeters. Ion CT (iCT) represents a favorable solution allowing to directly assess the RSP. In this simulation study we investigate the performance of the integration-mode configuration for carbon iCT, in comparison with a single-particle approach under the same set-up. The experimental detector consists of a stack of 61 air-filled parallel-plate ionization chambers, interleaved with 3 mm thick PMMA absorbers. By means of Monte Carlo simulations, this design was applied to acquire iCTs of phantoms of tissue-equivalent materials. An optimization of the acquisition parameters was performed to reduce the dose exposure, and the implications of a reduced absorber thickness were assessed. In order to overcome limitations of integration-mode detection in the presence of lateral tissue heterogeneities a dedicated post-processing method using a linear decomposition of the detector signal was developed and its performance was compared to the list-mode acquisition. For the current set-up, the phantom dose could be reduced to below 30 mGy with only minor image quality degradation. By using the decomposition method a correct identification of the components and a RSP accuracy improvement of around 2.0% was obtained. The comparison of integration- and list-mode indicated a slightly better image quality of the latter, with an average median RSP error below 1.8% and 1.0%, respectively. With a decreased absorber thickness a reduced RSP error was observed. Overall, these findings support the potential of iCT for low dose RSP estimation, showing that integration-mode detectors with dedicated post-processing strategies can provide a RSP accuracy comparable to list-mode configurations.
Item Description:Gesehen am 29.10.2018
Physical Description:Online Resource
ISSN:1361-6560
DOI:10.1088/1361-6560/aa5602