DCE‐MRI of the human kidney using BLADE: a feasibility study in healthy volunteers

Purpose: To evaluate the degree of motion compensation in the kidney using two different sampling methods, each in their optimized settings: A BLADE k‐space acquisition technique and a routinely used kidney perfusion acquisition scheme (TurboFLASH). Materials and Methods: Dynamic contrast enhanced m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Lietzmann, Florian (VerfasserIn) , Zöllner, Frank G. (VerfasserIn) , Attenberger, Ulrike (VerfasserIn) , Haneder, Stefan (VerfasserIn) , Michaely, Henrik J. M. (VerfasserIn) , Schad, Lothar R. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2012
In: Journal of magnetic resonance imaging
Year: 2012, Jahrgang: 35, Heft: 4, Pages: 868-874
ISSN:1522-2586
DOI:10.1002/jmri.23509
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1002/jmri.23509
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.23509
Volltext
Verfasserangaben:Florian Lietzmann, Frank G. Zöllner, Ulrike I. Attenberger, Stefan Haneder, Henrik J. Michaely, and Lothar R. Schad

MARC

LEADER 00000caa a2200000 c 4500
001 158359499X
003 DE-627
005 20220815052159.0
007 cr uuu---uuuuu
008 181110s2012 xx |||||o 00| ||eng c
024 7 |a 10.1002/jmri.23509  |2 doi 
035 |a (DE-627)158359499X 
035 |a (DE-576)51359499X 
035 |a (DE-599)BSZ51359499X 
035 |a (OCoLC)1341022529 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Lietzmann, Florian  |e VerfasserIn  |0 (DE-588)1029176574  |0 (DE-627)732555590  |0 (DE-576)377058092  |4 aut 
245 1 0 |a DCE‐MRI of the human kidney using BLADE  |b a feasibility study in healthy volunteers  |c Florian Lietzmann, Frank G. Zöllner, Ulrike I. Attenberger, Stefan Haneder, Henrik J. Michaely, and Lothar R. Schad 
264 1 |c 2012 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published: 29 November 2011 
500 |a Gesehen am 10.11.2019 
520 |a Purpose: To evaluate the degree of motion compensation in the kidney using two different sampling methods, each in their optimized settings: A BLADE k‐space acquisition technique and a routinely used kidney perfusion acquisition scheme (TurboFLASH). Materials and Methods: Dynamic contrast enhanced magnetic resonance examinations were performed in 16 healthy volunteers on a 3 Tesla MR‐system with two parameterizations of the BLADE sequence and the standard reference acquisition scheme. Signal intensity enhanced time curves were analyzed with a mathematical model and a widely published separable compartment model on cortex regions to assess robustness versus motion artifacts. Results: BLADE‐measurements with a strip‐width of 32 lines constituted the smallest mean values for the sum of squared errors (6065 ± 4996) compared with the measurement with a strip‐width of 64 lines (13849 ± 14079) or the standard TurboFLASH (11884 ± 8076). Calculations concerning goodness of the fit of the applied compartment model yielded an overall average of the Akaike Fit Error of 732 ± 141 for BLADE (646 ± 149 for a strip‐width of 32 lines, 816 ± 53 for 64 lines) and 1626 ± 303 for the TurboFLASH (TFL) sequence. Conclusion: We demonstrated that renal dynamic contrast enhanced magnetic resonance imaging using BLADE k‐space sampling with a strip‐width of 32 is significantly less sensitive to motion than a widely published Turbo‐Flash sequence with nearly similar parameters. 
700 1 |a Zöllner, Frank G.  |d 1976-  |e VerfasserIn  |0 (DE-588)129580015  |0 (DE-627)473357054  |0 (DE-576)297732587  |4 aut 
700 1 |a Attenberger, Ulrike  |d 1980-  |e VerfasserIn  |0 (DE-588)131554859  |0 (DE-627)510698557  |0 (DE-576)298582775  |4 aut 
700 1 |a Haneder, Stefan  |d 1981-  |e VerfasserIn  |0 (DE-588)136678335  |0 (DE-627)585462097  |0 (DE-576)287960943  |4 aut 
700 1 |a Michaely, Henrik J. M.  |d 1976-  |e VerfasserIn  |0 (DE-588)128817283  |0 (DE-627)381568407  |0 (DE-576)297347624  |4 aut 
700 1 |a Schad, Lothar R.  |d 1956-  |e VerfasserIn  |0 (DE-588)1028817630  |0 (DE-627)731640241  |0 (DE-576)376271221  |4 aut 
773 0 8 |i Enthalten in  |t Journal of magnetic resonance imaging  |d New York, NY : Wiley-Liss, 1991  |g 35(2012), 4, Seite 868-874  |h Online-Ressource  |w (DE-627)306360039  |w (DE-600)1497154-9  |w (DE-576)114617252  |x 1522-2586  |7 nnas  |a DCE‐MRI of the human kidney using BLADE a feasibility study in healthy volunteers 
773 1 8 |g volume:35  |g year:2012  |g number:4  |g pages:868-874  |g extent:7  |a DCE‐MRI of the human kidney using BLADE a feasibility study in healthy volunteers 
787 0 8 |i Forschungsdaten  |a Zöllner, Frank G., 1976 -   |t DCE-MRI of the human kidney using BLADE  |d Heidelberg : Universität, 2019  |h 1 Online-Ressource (1 File)  |w (DE-627)165576750X  |w (DE-576)518326616 
856 4 0 |u http://dx.doi.org/10.1002/jmri.23509  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.23509  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20181110 
993 |a Article 
994 |a 2012 
998 |g 1028817630  |a Schad, Lothar R.  |m 1028817630:Schad, Lothar R.  |p 6  |y j 
998 |g 128817283  |a Michaely, Henrik J. M.  |m 128817283:Michaely, Henrik J. M.  |d 60000  |d 62900  |e 60000PM128817283  |e 62900PM128817283  |k 0/60000/  |k 1/60000/62900/  |p 5 
998 |g 136678335  |a Haneder, Stefan  |m 136678335:Haneder, Stefan  |d 60000  |d 62900  |e 60000PH136678335  |e 62900PH136678335  |k 0/60000/  |k 1/60000/62900/  |p 4 
998 |g 131554859  |a Attenberger, Ulrike  |m 131554859:Attenberger, Ulrike  |d 60000  |d 62900  |e 60000PA131554859  |e 62900PA131554859  |k 0/60000/  |k 1/60000/62900/  |p 3 
998 |g 129580015  |a Zöllner, Frank G.  |m 129580015:Zöllner, Frank G.  |p 2 
998 |g 1029176574  |a Lietzmann, Florian  |m 1029176574:Lietzmann, Florian  |p 1  |x j 
999 |a KXP-PPN158359499X  |e 3031910435 
BIB |a Y 
SER |a journal 
JSO |a {"note":["First published: 29 November 2011","Gesehen am 10.11.2019"],"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2012"}],"title":[{"title":"DCE‐MRI of the human kidney using BLADE","title_sort":"DCE‐MRI of the human kidney using BLADE","subtitle":"a feasibility study in healthy volunteers"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"158359499X","relHost":[{"part":{"year":"2012","pages":"868-874","text":"35(2012), 4, Seite 868-874","issue":"4","extent":"7","volume":"35"},"titleAlt":[{"title":"JMRI"}],"language":["eng"],"id":{"eki":["306360039"],"doi":["10.1002/(ISSN)1522-2586"],"issn":["1522-2586"],"zdb":["1497154-9"]},"recId":"306360039","physDesc":[{"extent":"Online-Ressource"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"DCE‐MRI of the human kidney using BLADE a feasibility study in healthy volunteersJournal of magnetic resonance imaging","pubHistory":["1.1991 -"],"origin":[{"publisherPlace":"New York, NY","dateIssuedDisp":"1991-","dateIssuedKey":"1991","publisher":"Wiley-Liss"}],"note":["Gesehen am 28.02.08","Fortsetzung der CD-ROM-Ausgabe"],"title":[{"title":"Journal of magnetic resonance imaging","subtitle":"JMRI ; an official journal of the International Society for Magnetic Resonance in Medicine","title_sort":"Journal of magnetic resonance imaging"}]}],"name":{"displayForm":["Florian Lietzmann, Frank G. Zöllner, Ulrike I. Attenberger, Stefan Haneder, Henrik J. Michaely, and Lothar R. Schad"]},"physDesc":[{"extent":"7 S."}],"id":{"doi":["10.1002/jmri.23509"],"eki":["158359499X"]},"person":[{"given":"Florian","role":"aut","family":"Lietzmann","display":"Lietzmann, Florian"},{"display":"Zöllner, Frank G.","family":"Zöllner","role":"aut","given":"Frank G."},{"display":"Attenberger, Ulrike","family":"Attenberger","role":"aut","given":"Ulrike"},{"given":"Stefan","role":"aut","family":"Haneder","display":"Haneder, Stefan"},{"role":"aut","given":"Henrik J. M.","family":"Michaely","display":"Michaely, Henrik J. M."},{"given":"Lothar R.","role":"aut","display":"Schad, Lothar R.","family":"Schad"}],"language":["eng"]} 
SRT |a LIETZMANNFDCEMRIOFTH2012