Arterial spin labeling at 3.0 Tesla in subacute ischemia: comparison to dynamic susceptibility perfusion

PurposeArterial spin labeling (ASL) is a promising but clinically not established non-invasive method to assess cerebral perfusion. The purpose of this study was to compare perfusion imaging with pulsed ASL (pASL) to conventional dynamic susceptibility contrast (DSC) perfusion-weighted imaging (PWL)...

Full description

Saved in:
Bibliographic Details
Main Authors: Huck, Sonia (Author) , Kerl, Hans Ulrich (Author) , Al-Zghloul, Mansour (Author) , Groden, Christoph (Author) , Nölte, Ingo (Author)
Format: Article (Journal)
Language:English
Published: March 2012
In: Clinical neuroradiology
Year: 2012, Volume: 22, Issue: 1, Pages: 29-37
ISSN:1869-1447
DOI:10.1007/s00062-011-0126-x
Online Access:Verlag, Volltext: http://dx.doi.org/10.1007/s00062-011-0126-x
Verlag, Volltext: https://doi.org/10.1007/s00062-011-0126-x
Get full text
Author Notes:S. Huck, H.U. Kerl, M. Al-Zghloul, C. Groden, I. Nölte

MARC

LEADER 00000caa a2200000 c 4500
001 1583604278
003 DE-627
005 20250206100619.0
007 cr uuu---uuuuu
008 181112s2012 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00062-011-0126-x  |2 doi 
035 |a (DE-627)1583604278 
035 |a (DE-576)513604278 
035 |a (DE-599)BSZ513604278 
035 |a (OCoLC)1341022493 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Huck, Sonia  |d 1982-  |e VerfasserIn  |0 (DE-588)141668431  |0 (DE-627)630411948  |0 (DE-576)32504354X  |4 aut 
245 1 0 |a Arterial spin labeling at 3.0 Tesla in subacute ischemia  |b comparison to dynamic susceptibility perfusion  |c S. Huck, H.U. Kerl, M. Al-Zghloul, C. Groden, I. Nölte 
264 1 |c March 2012 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 12.11.2018 
520 |a PurposeArterial spin labeling (ASL) is a promising but clinically not established non-invasive method to assess cerebral perfusion. The purpose of this study was to compare perfusion imaging with pulsed ASL (pASL) to conventional dynamic susceptibility contrast (DSC) perfusion-weighted imaging (PWL) using commercially available equipment and postprocessing (3.0 Tesla, 32-channel head coil) in patients with subacute ischemia.MethodsThe pASL and DSC-PWI techniques were compared in 15 patients with subacute ischemia (age 49-88 years, 6 females and 9 males, time from onset to scan 4-161 h). Image inhomogeneity was assessed with the non-uniformity index. Image quality, delineation of hypoperfusion and degree of hypoperfusion were rated by two readers using a 5-scale grading system. The volume of hypoperfusion was quantified planimetrically.ResultsImage quality and image inhomogeneity were superior in DSC time-to-peak (TTP) compared to pASL cerebral brain flow (CBF; both p < 0.05). The delineation of hypoperfusion was better in DSC-TTP (p < 0.05) and the hypoperfusion was graded as more severe in DSC-TTP (p < 0.05). The volume of hypoperfusion did not differ between pASL-CBF and DSC-TTP, however, in pASL-CBF five cases with small infarctions (lacunar and pontine) were false negative compared to DSC-relative CBF. The mismatch frequency was lower in pASL (13%) than in DSC-rCBF (20%) and DSC-TTP (47%).ConclusionsUsing a commercially available sequence and a 32-channel head coil at 3.0 Tesla pASL-CBF is feasible but limited compared to DSC-PWI in the assessment of ischemic stroke. In its present form pASL has a reserve role in clinical practice for situations when gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) is contraindicated. 
650 4 |a Arterial spin labeling (ASL) 
650 4 |a Cerebral perfusion 
650 4 |a Dynamic susceptibility imaging 
650 4 |a Magnetic resonance imaging (MRI) 
650 4 |a Stroke 
650 4 |a Subacute ischemia 
700 1 |a Kerl, Hans Ulrich  |d 1977-  |e VerfasserIn  |0 (DE-588)130070742  |0 (DE-627)489616216  |0 (DE-576)297980823  |4 aut 
700 1 |a Al-Zghloul, Mansour  |d 1974-  |e VerfasserIn  |0 (DE-588)1028271263  |0 (DE-627)730505332  |0 (DE-576)375756876  |4 aut 
700 1 |a Groden, Christoph  |d 1959-  |e VerfasserIn  |0 (DE-588)11292641X  |0 (DE-627)691165742  |0 (DE-576)331358948  |4 aut 
700 1 |a Nölte, Ingo  |d 1974-  |e VerfasserIn  |0 (DE-588)1028271778  |0 (DE-627)73050669X  |0 (DE-576)375758046  |4 aut 
773 0 8 |i Enthalten in  |t Clinical neuroradiology  |d München : Urban & Vogel, 2006  |g 22(2012), 1, Seite 29-37  |h Online-Ressource  |w (DE-627)510935257  |w (DE-600)2232347-8  |w (DE-576)252954327  |x 1869-1447  |7 nnas  |a Arterial spin labeling at 3.0 Tesla in subacute ischemia comparison to dynamic susceptibility perfusion 
773 1 8 |g volume:22  |g year:2012  |g number:1  |g pages:29-37  |g extent:9  |a Arterial spin labeling at 3.0 Tesla in subacute ischemia comparison to dynamic susceptibility perfusion 
856 4 0 |u http://dx.doi.org/10.1007/s00062-011-0126-x  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://doi.org/10.1007/s00062-011-0126-x  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20181112 
993 |a Article 
994 |a 2012 
998 |g 1028271778  |a Nölte, Ingo  |m 1028271778:Nölte, Ingo  |d 60000  |d 63000  |e 60000PN1028271778  |e 63000PN1028271778  |k 0/60000/  |k 1/60000/63000/  |p 5  |y j 
998 |g 11292641X  |a Groden, Christoph  |m 11292641X:Groden, Christoph  |d 60000  |d 63000  |e 60000PG11292641X  |e 63000PG11292641X  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 1028271263  |a Al-Zghloul, Mansour  |m 1028271263:Al-Zghloul, Mansour  |d 60000  |e 60000PA1028271263  |k 0/60000/  |p 3 
998 |g 130070742  |a Kerl, Hans Ulrich  |m 130070742:Kerl, Hans Ulrich  |d 60000  |d 63000  |e 60000PK130070742  |e 63000PK130070742  |k 0/60000/  |k 1/60000/63000/  |p 2 
998 |g 141668431  |a Huck, Sonia  |m 141668431:Huck, Sonia  |d 60000  |d 63000  |e 60000PH141668431  |e 63000PH141668431  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN1583604278  |e 3032016258 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1583604278","language":["eng"],"note":["Gesehen am 12.11.2018"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"role":"aut","display":"Huck, Sonia","roleDisplay":"VerfasserIn","given":"Sonia","family":"Huck"},{"family":"Kerl","given":"Hans Ulrich","display":"Kerl, Hans Ulrich","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Al-Zghloul","given":"Mansour","display":"Al-Zghloul, Mansour","roleDisplay":"VerfasserIn","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Groden, Christoph","role":"aut","family":"Groden","given":"Christoph"},{"display":"Nölte, Ingo","roleDisplay":"VerfasserIn","role":"aut","family":"Nölte","given":"Ingo"}],"title":[{"title_sort":"Arterial spin labeling at 3.0 Tesla in subacute ischemia","subtitle":"comparison to dynamic susceptibility perfusion","title":"Arterial spin labeling at 3.0 Tesla in subacute ischemia"}],"relHost":[{"title":[{"title_sort":"Clinical neuroradiology","title":"Clinical neuroradiology","subtitle":"official publication of the German, Austrian and Swiss societies of neuroradiology"}],"part":{"volume":"22","text":"22(2012), 1, Seite 29-37","extent":"9","year":"2012","issue":"1","pages":"29-37"},"pubHistory":["16.2006 -"],"language":["eng"],"recId":"510935257","disp":"Arterial spin labeling at 3.0 Tesla in subacute ischemia comparison to dynamic susceptibility perfusionClinical neuroradiology","note":["Gesehen am 27.09.2018"],"type":{"media":"Online-Ressource","bibl":"periodical"},"id":{"eki":["510935257"],"zdb":["2232347-8"],"issn":["1869-1447","1615-6706"]},"origin":[{"dateIssuedDisp":"2006-","publisher":"Urban & Vogel","dateIssuedKey":"2006","publisherPlace":"München"}],"physDesc":[{"extent":"Online-Ressource"}]}],"physDesc":[{"extent":"9 S."}],"name":{"displayForm":["S. Huck, H.U. Kerl, M. Al-Zghloul, C. Groden, I. Nölte"]},"id":{"eki":["1583604278"],"doi":["10.1007/s00062-011-0126-x"]},"origin":[{"dateIssuedDisp":"March 2012","dateIssuedKey":"2012"}]} 
SRT |a HUCKSONIAKARTERIALSP2012