Stand-alone mapping using different transluminal mapping catheters: an accurate and safe way to isolate all pulmonary veins with the cryoballoon?
Purpose: Cryoballoon isolation of the pulmonary veins (PVI) is an effective and safe method in the treatment of patients with paroxysmal atrial fibrillation (PAF). The circular mapping catheter Achieve (Medtronic Inc., Minneapolis, USA) can be introduced into the pulmonary vein (PV) through the inne...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
January 2015
|
| In: |
Journal of interventional cardiac electrophysiology
Year: 2015, Volume: 42, Issue: 1, Pages: 33-41 |
| ISSN: | 1572-8595 |
| DOI: | 10.1007/s10840-014-9957-0 |
| Online Access: | Verlag, Volltext: http://dx.doi.org/10.1007/s10840-014-9957-0 Verlag, Volltext: https://doi.org/10.1007/s10840-014-9957-0 |
| Author Notes: | Anja Schade, Burghard Schumacher, Johannes W. Dietrich, Anke Langbein, Guido Groschup, Katrin Koucky, Joachim Krug, Carsten Stahl, Patrick Müller, Karin Nentwich, Markus Roos, Thomas Deneke |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1583821597 | ||
| 003 | DE-627 | ||
| 005 | 20220815060312.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 181119s2015 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s10840-014-9957-0 |2 doi | |
| 035 | |a (DE-627)1583821597 | ||
| 035 | |a (DE-576)513821597 | ||
| 035 | |a (DE-599)BSZ513821597 | ||
| 035 | |a (OCoLC)1341023658 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Schade, Anja |d 1973- |e VerfasserIn |0 (DE-588)131403176 |0 (DE-627)707620015 |0 (DE-576)298455137 |4 aut | |
| 245 | 1 | 0 | |a Stand-alone mapping using different transluminal mapping catheters |b an accurate and safe way to isolate all pulmonary veins with the cryoballoon? |c Anja Schade, Burghard Schumacher, Johannes W. Dietrich, Anke Langbein, Guido Groschup, Katrin Koucky, Joachim Krug, Carsten Stahl, Patrick Müller, Karin Nentwich, Markus Roos, Thomas Deneke |
| 264 | 1 | |c January 2015 | |
| 300 | |a 9 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 19.11.2018 | ||
| 500 | |a Published online: 13 December 2014 | ||
| 520 | |a Purpose: Cryoballoon isolation of the pulmonary veins (PVI) is an effective and safe method in the treatment of patients with paroxysmal atrial fibrillation (PAF). The circular mapping catheter Achieve (Medtronic Inc., Minneapolis, USA) can be introduced into the pulmonary vein (PV) through the inner lumen of the balloon catheter, allowing online mapping of the PV electrograms during ablation. We prospectively compared the accuracy of this catheter in both available sizes to a standard circular mapping catheter (SCMC) in order to determine bidirectional PV block. Methods: Patients with symptomatic PAF underwent cryoballoon ablation using either the Achieve 15-mm catheter (group 1, 15 patients) or the Achieve 20 mm (group 2, 15 patients). PV potentials were recorded using Achieve before, during, and after ablation, and exit block was obtained by pacing from inside the PV. Accuracy of PV potential detection was controlled by a SCMC before and after ablation. Results: Rate of PV which could be isolated exclusively using the Achieve as guidewire was 98 % (59/60) in group 1 and 93 % (57/60) in group 2. Online signal recording during ablation was possible in 40 and 60 % of PV (p = 0.037), respectively. Final Achieve diagnosis was accurate in 55/60 (92 %) of the PVs and 12/15 (80 %) of patients in group 1 and 60/60 (100 %) of PV and 15/15 (100 %) of patients in group 2. Conclusion: Stand-alone mapping using Achieve 15 mm resulted in a significant lack of diagnostic accuracy. Achieve 20 mm provided excellent diagnostic accuracy comparable to a SCMC and should be preferentially used. | ||
| 650 | 4 | |a Achieve catheter | |
| 650 | 4 | |a Atrial fibrillation | |
| 650 | 4 | |a Cryoballoon ablation | |
| 650 | 4 | |a Inner lumen mapping catheter | |
| 650 | 4 | |a Pulmonary vein isolation | |
| 700 | 1 | |a Schumacher, Burghard |d 1965- |e VerfasserIn |0 (DE-588)1068294590 |0 (DE-627)820030481 |0 (DE-576)427619793 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of interventional cardiac electrophysiology |d New York, USA : Springer Science + Business Media, 1997 |g 42(2015), 1, Seite 33-41 |h Online-Ressource |w (DE-627)320457869 |w (DE-600)2006887-6 |w (DE-576)121465578 |x 1572-8595 |7 nnas |a Stand-alone mapping using different transluminal mapping catheters an accurate and safe way to isolate all pulmonary veins with the cryoballoon? |
| 773 | 1 | 8 | |g volume:42 |g year:2015 |g number:1 |g pages:33-41 |g extent:9 |a Stand-alone mapping using different transluminal mapping catheters an accurate and safe way to isolate all pulmonary veins with the cryoballoon? |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1007/s10840-014-9957-0 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s10840-014-9957-0 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20181119 | ||
| 993 | |a Article | ||
| 994 | |a 2015 | ||
| 998 | |g 1068294590 |a Schumacher, Burghard |m 1068294590:Schumacher, Burghard |d 60000 |e 60000PS1068294590 |k 0/60000/ |p 2 | ||
| 999 | |a KXP-PPN1583821597 |e 3032663482 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"physDesc":[{"extent":"9 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["320457869"],"zdb":["2006887-6"],"issn":["1572-8595"]},"origin":[{"dateIssuedKey":"1997","publisher":"Springer Science + Business Media ; Kluwer ; Springer Science + Business Media B.V.","dateIssuedDisp":"1997-","publisherPlace":"New York, USA ; Dordrecht [u.a.] ; Dordrecht [u.a.]"}],"recId":"320457869","language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Stand-alone mapping using different transluminal mapping catheters an accurate and safe way to isolate all pulmonary veins with the cryoballoon?Journal of interventional cardiac electrophysiology","note":["Gesehen am 09.03.05","Fortsetzung der Druck-Ausgabe"],"part":{"text":"42(2015), 1, Seite 33-41","volume":"42","extent":"9","year":"2015","pages":"33-41","issue":"1"},"titleAlt":[{"title":"An international journal of arrhythmias and pacing"}],"pubHistory":["1.1997 -"],"title":[{"title_sort":"Journal of interventional cardiac electrophysiology","title":"Journal of interventional cardiac electrophysiology","subtitle":"an international journal of cardiac arrhythmias and rhythm management"}]}],"origin":[{"dateIssuedDisp":"January 2015","dateIssuedKey":"2015"}],"id":{"eki":["1583821597"],"doi":["10.1007/s10840-014-9957-0"]},"name":{"displayForm":["Anja Schade, Burghard Schumacher, Johannes W. Dietrich, Anke Langbein, Guido Groschup, Katrin Koucky, Joachim Krug, Carsten Stahl, Patrick Müller, Karin Nentwich, Markus Roos, Thomas Deneke"]},"note":["Gesehen am 19.11.2018","Published online: 13 December 2014"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1583821597","language":["eng"],"title":[{"title":"Stand-alone mapping using different transluminal mapping catheters","subtitle":"an accurate and safe way to isolate all pulmonary veins with the cryoballoon?","title_sort":"Stand-alone mapping using different transluminal mapping catheters"}],"person":[{"display":"Schade, Anja","roleDisplay":"VerfasserIn","role":"aut","family":"Schade","given":"Anja"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Schumacher, Burghard","given":"Burghard","family":"Schumacher"}]} | ||
| SRT | |a SCHADEANJASTANDALONE2015 | ||