Implementation of dual-source RF excitation in 3 T MR-scanners allows for nearly identical ADC values compared to 1.5 T MR scanners in the abdomen
Background To retrospectively and prospectively compare abdominal apparent diffusion coefficient (ADC) values obtained within in a 1.5 T system and 3 T systems with and without dual-source parallel RF excitation techniques. Methodology/Principal Findings After IRB approval, diffusion-weighted (DW) i...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
February 29, 2012
|
| In: |
PLOS ONE
Year: 2012, Jahrgang: 7, Heft: 2 |
| ISSN: | 1932-6203 |
| DOI: | 10.1371/journal.pone.0032613 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1371/journal.pone.0032613 Verlag, kostenfrei, Volltext: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0032613 |
| Verfasserangaben: | Raghuram K. Rao, Philipp Riffel, Mathias Meyer, Paul J. Kettnaker, Andreas Lemke, Stefan Haneder, Stefan O. Schoenberg, Henrik J. Michaely |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1583903836 | ||
| 003 | DE-627 | ||
| 005 | 20220815061930.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 181121s2012 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1371/journal.pone.0032613 |2 doi | |
| 035 | |a (DE-627)1583903836 | ||
| 035 | |a (DE-576)513903836 | ||
| 035 | |a (DE-599)BSZ513903836 | ||
| 035 | |a (OCoLC)1341023670 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Rao, Raghuram K. |e VerfasserIn |0 (DE-588)117190892X |0 (DE-627)1041697198 |0 (DE-576)513903046 |4 aut | |
| 245 | 1 | 0 | |a Implementation of dual-source RF excitation in 3 T MR-scanners allows for nearly identical ADC values compared to 1.5 T MR scanners in the abdomen |c Raghuram K. Rao, Philipp Riffel, Mathias Meyer, Paul J. Kettnaker, Andreas Lemke, Stefan Haneder, Stefan O. Schoenberg, Henrik J. Michaely |
| 264 | 1 | |c February 29, 2012 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 21.11.2018 | ||
| 520 | |a Background To retrospectively and prospectively compare abdominal apparent diffusion coefficient (ADC) values obtained within in a 1.5 T system and 3 T systems with and without dual-source parallel RF excitation techniques. Methodology/Principal Findings After IRB approval, diffusion-weighted (DW) images of the abdomen were obtained on three different MR systems (1.5 T, a first generation 3 T, and a second generation 3 T which incorporates dual-source parallel RF excitation) on 150 patients retrospectively and 19 volunteers (57 examinations total) prospectively. Seven regions of interest (ROI) were throughout the abdomen were selected to measure the ADC. Statistical analysis included independent two-sided t-tests, Mann-Whitney U tests and correlation analysis. In the DW images of the abdomen, mean ADC values were nearly identical with nonsignificant differences when comparing the 1.5 T and second generation 3 T systems in all seven anatomical regions in the patient population and six of the seven in the volunteer population (p>0.05 in all distributions). The strength of correlation measured in the volunteer population between the two scanners in the kidneys ranged from r = 0.64-0.88 and in the remaining regions (besides the spleen), r>0.85. In the patient population the first generation 3 T scanner had different mean ADC values with significant differences (p<0.05) compared to the other two scanners in each of the seven distributions. In the volunteer population, the kidneys shared similar ADC mean values in comparison to the other two scanners with nonsignificant differences. Conclusions/Significance A second generation 3 T scanner with dual-source parallel RF excitation provides nearly identical ADC values compared with the 1.5 T imaging system in abdominal imaging. | ||
| 650 | 4 | |a Abdomen | |
| 650 | 4 | |a Adenocarcinomas | |
| 650 | 4 | |a Diffusion weighted imaging | |
| 650 | 4 | |a Kidneys | |
| 650 | 4 | |a Liver and spleen scan | |
| 650 | 4 | |a Magnetic resonance imaging | |
| 650 | 4 | |a Pancreas | |
| 650 | 4 | |a Spleen | |
| 700 | 1 | |a Riffel, Philipp |d 1982- |e VerfasserIn |0 (DE-588)1055978860 |0 (DE-627)793010756 |0 (DE-576)358923433 |4 aut | |
| 700 | 1 | |a Meyer, Mathias |d 1986- |e VerfasserIn |0 (DE-588)1025310306 |0 (DE-627)722026021 |0 (DE-576)370193059 |4 aut | |
| 700 | 1 | |a Kettnaker, Paul |d 1985- |e VerfasserIn |0 (DE-588)1048347753 |0 (DE-627)780144198 |0 (DE-576)402158075 |4 aut | |
| 700 | 1 | |a Lemke, Andreas |e VerfasserIn |0 (DE-588)1014144787 |0 (DE-627)705174360 |0 (DE-576)348356862 |4 aut | |
| 700 | 1 | |a Haneder, Stefan |d 1981- |e VerfasserIn |0 (DE-588)136678335 |0 (DE-627)585462097 |0 (DE-576)287960943 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Michaely, Henrik J. M. |d 1976- |e VerfasserIn |0 (DE-588)128817283 |0 (DE-627)381568407 |0 (DE-576)297347624 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t PLOS ONE |d San Francisco, California, US : PLOS, 2006 |g 7(2012), 2, Artikel-ID e32613 |h Online-Ressource |w (DE-627)523574592 |w (DE-600)2267670-3 |w (DE-576)281331979 |x 1932-6203 |7 nnas |a Implementation of dual-source RF excitation in 3 T MR-scanners allows for nearly identical ADC values compared to 1.5 T MR scanners in the abdomen |
| 773 | 1 | 8 | |g volume:7 |g year:2012 |g number:2 |g elocationid:e32613 |g extent:8 |a Implementation of dual-source RF excitation in 3 T MR-scanners allows for nearly identical ADC values compared to 1.5 T MR scanners in the abdomen |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1371/journal.pone.0032613 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0032613 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20181121 | ||
| 993 | |a Article | ||
| 994 | |a 2012 | ||
| 998 | |g 128817283 |a Michaely, Henrik J. M. |m 128817283:Michaely, Henrik J. M. |d 60000 |d 62900 |e 60000PM128817283 |e 62900PM128817283 |k 0/60000/ |k 1/60000/62900/ |p 8 |y j | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 7 | ||
| 998 | |g 136678335 |a Haneder, Stefan |m 136678335:Haneder, Stefan |d 60000 |d 62900 |e 60000PH136678335 |e 62900PH136678335 |k 0/60000/ |k 1/60000/62900/ |p 6 | ||
| 998 | |g 1014144787 |a Lemke, Andreas |m 1014144787:Lemke, Andreas |p 5 | ||
| 998 | |g 1048347753 |a Kettnaker, Paul |m 1048347753:Kettnaker, Paul |d 60000 |d 62900 |e 60000PK1048347753 |e 62900PK1048347753 |k 0/60000/ |k 1/60000/62900/ |p 4 | ||
| 998 | |g 1025310306 |a Meyer, Mathias |m 1025310306:Meyer, Mathias |d 60000 |d 62900 |e 60000PM1025310306 |e 62900PM1025310306 |k 0/60000/ |k 1/60000/62900/ |p 3 | ||
| 998 | |g 1055978860 |a Riffel, Philipp |m 1055978860:Riffel, Philipp |d 60000 |d 62900 |e 60000PR1055978860 |e 62900PR1055978860 |k 0/60000/ |k 1/60000/62900/ |p 2 | ||
| 998 | |g 117190892X |a Rao, Raghuram K. |m 117190892X:Rao, Raghuram K. |d 60000 |d 62900 |e 60000PR117190892X |e 62900PR117190892X |k 0/60000/ |k 1/60000/62900/ |p 1 |x j | ||
| 999 | |a KXP-PPN1583903836 |e 303282902X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"title":[{"title_sort":"PLOS ONE","title":"PLOS ONE"}],"corporate":[{"display":"Public Library of Science","role":"isb"}],"name":{"displayForm":["Public Library of Science"]},"origin":[{"publisher":"PLOS ; PLoS","dateIssuedDisp":"2006-","dateIssuedKey":"2006","publisherPlace":"San Francisco, California, US ; Lawrence, Kan."}],"note":["Schreibweise des Titels bis 2012: PLoS ONE","Gesehen am 20.03.19"],"physDesc":[{"extent":"Online-Ressource"}],"part":{"text":"7(2012), 2, Artikel-ID e32613","volume":"7","issue":"2","year":"2012","extent":"8"},"id":{"zdb":["2267670-3"],"issn":["1932-6203"],"eki":["523574592"]},"language":["eng"],"recId":"523574592","disp":"Implementation of dual-source RF excitation in 3 T MR-scanners allows for nearly identical ADC values compared to 1.5 T MR scanners in the abdomenPLOS ONE","type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.2006 -"]}],"note":["Gesehen am 21.11.2018"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"doi":["10.1371/journal.pone.0032613"],"eki":["1583903836"]},"physDesc":[{"extent":"8 S."}],"language":["eng"],"title":[{"title_sort":"Implementation of dual-source RF excitation in 3 T MR-scanners allows for nearly identical ADC values compared to 1.5 T MR scanners in the abdomen","title":"Implementation of dual-source RF excitation in 3 T MR-scanners allows for nearly identical ADC values compared to 1.5 T MR scanners in the abdomen"}],"recId":"1583903836","name":{"displayForm":["Raghuram K. Rao, Philipp Riffel, Mathias Meyer, Paul J. Kettnaker, Andreas Lemke, Stefan Haneder, Stefan O. Schoenberg, Henrik J. Michaely"]},"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"February 29, 2012"}],"person":[{"role":"aut","given":"Raghuram K.","display":"Rao, Raghuram K.","family":"Rao"},{"role":"aut","display":"Riffel, Philipp","given":"Philipp","family":"Riffel"},{"family":"Meyer","display":"Meyer, Mathias","given":"Mathias","role":"aut"},{"family":"Kettnaker","given":"Paul","display":"Kettnaker, Paul","role":"aut"},{"family":"Lemke","display":"Lemke, Andreas","given":"Andreas","role":"aut"},{"role":"aut","display":"Haneder, Stefan","given":"Stefan","family":"Haneder"},{"family":"Schönberg","display":"Schönberg, Stefan","given":"Stefan","role":"aut"},{"given":"Henrik J. M.","display":"Michaely, Henrik J. M.","family":"Michaely","role":"aut"}]} | ||
| SRT | |a RAORAGHURAIMPLEMENTA2920 | ||