Comparison of digital subtraction angiography, micro-computed tomography angiography and magnetic resonance angiography in the assessment of the cerebrovascular system in live mice

PurposeMice are often used as small animal models of brain ischemia, venous thrombosis, or vasospasm. This article aimed at providing an overview of the currently available methodologies for in vivo imaging of the murine cerebrovasculature and comparing the capabilities and limitations of the differ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Negrão de Figueiredo Miller, Giovanna (VerfasserIn) , Brockmann, Carolin (VerfasserIn) , Boll, Hanne (VerfasserIn) , Heilmann, Melanie (VerfasserIn) , Schambach, Sebastian Jobst (VerfasserIn) , Fiebig, Anna Teresa (VerfasserIn) , Groden, Christoph (VerfasserIn) , Brockmann, Marc Alexander (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: March 2012
In: Clinical neuroradiology
Year: 2012, Jahrgang: 22, Heft: 1, Pages: 21-28
ISSN:1869-1447
DOI:10.1007/s00062-011-0113-2
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1007/s00062-011-0113-2
Verlag, Volltext: https://doi.org/10.1007/s00062-011-0113-2
Volltext
Verfasserangaben:G. Figueiredo, C. Brockmann, H. Boll, M. Heilmann, S.J. Schambach, T. Fiebig, M. Kramer, C. Groden, M.A. Brockmann

MARC

LEADER 00000caa a2200000 c 4500
001 1583989307
003 DE-627
005 20220815063521.0
007 cr uuu---uuuuu
008 181123s2012 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00062-011-0113-2  |2 doi 
035 |a (DE-627)1583989307 
035 |a (DE-576)513989307 
035 |a (DE-599)BSZ513989307 
035 |a (OCoLC)1341024022 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Negrão de Figueiredo Miller, Giovanna  |d 1985-  |e VerfasserIn  |0 (DE-588)1038464072  |0 (DE-627)757451527  |0 (DE-576)392428741  |4 aut 
245 1 0 |a Comparison of digital subtraction angiography, micro-computed tomography angiography and magnetic resonance angiography in the assessment of the cerebrovascular system in live mice  |c G. Figueiredo, C. Brockmann, H. Boll, M. Heilmann, S.J. Schambach, T. Fiebig, M. Kramer, C. Groden, M.A. Brockmann 
264 1 |c March 2012 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online: 24 November 2011 
500 |a Gesehen am 30.11.2018 
520 |a PurposeMice are often used as small animal models of brain ischemia, venous thrombosis, or vasospasm. This article aimed at providing an overview of the currently available methodologies for in vivo imaging of the murine cerebrovasculature and comparing the capabilities and limitations of the different methods.MethodsMicro-computed tomography angiography (CTA) was performed during intra-arterial and intravenous administration of a contrast agent bolus. Digital subtraction angiography (DSA) was performed during intra-arterial administration of contrast agent using the micro-CT scanner. Time-of-flight (ToF) magnetic resonance (MR) angiography was performed using a small animal scanner (9.4 T) equipped with a cryogenic transceive quadrature coil. Datasets were compared for scan time, contrast-to-noise ratio (CNR), temporal and spatial resolution, radiation dose, contrast agent dose and detailed recognition of cerebrovascular structures.ResultsHighest spatial resolution was achieved using micro-CTA (16 ´ 16 ´ 16 µm) and DSA (14 ´ 14 µm). Compared to micro-CTA (20-40 s) and ToF-MRA (57 min), DSA provided highest temporal resolutions (30 fps) allowing analyses of the cerebrovascular blood flow. Highest mean CNR was reached using ToF-MRA (50.7 ± 15.0), while CNR of micro-CTA depended on the intra-arterial (19.0 ± 1.0) and intravenous (1.3 ± 0.4) use of agents. The CNR of DSA was 10.0 ± 1.8.ConclusionsThe use of dedicated small animal scanners allows cerebrovascular imaging in live animals as small as mice. As each of the methods analyzed has its advantages and limitations, choosing the best suited imaging modality for a defined question is of great importance. By this means the aforementioned methods offer a great potential for future projects in preclinical cerebrovascular research including ischemic stroke or vasospasm. 
650 4 |a Cerebrovascular circulation 
650 4 |a Digital subtraction angiography 
650 4 |a Magnetic resonance imaging 
650 4 |a Mice 
650 4 |a Tomography 
650 4 |a X-ray computed 
700 1 |a Brockmann, Carolin  |d 1977-  |e VerfasserIn  |0 (DE-588)1022165038  |0 (DE-627)716932806  |0 (DE-576)360612350  |4 aut 
700 1 |a Boll, Hanne  |d 1983-  |e VerfasserIn  |0 (DE-588)1025834739  |0 (DE-627)724883207  |0 (DE-576)370821408  |4 aut 
700 1 |a Heilmann, Melanie  |e VerfasserIn  |0 (DE-588)1021211362  |0 (DE-627)689759347  |0 (DE-576)362753199  |4 aut 
700 1 |a Schambach, Sebastian Jobst  |d 1979-  |e VerfasserIn  |0 (DE-588)140930795  |0 (DE-627)70383214X  |0 (DE-576)321270169  |4 aut 
700 1 |a Fiebig, Anna Teresa  |e VerfasserIn  |0 (DE-588)1050701593  |0 (DE-627)784655065  |0 (DE-576)404955592  |4 aut 
700 1 |a Groden, Christoph  |d 1959-  |e VerfasserIn  |0 (DE-588)11292641X  |0 (DE-627)691165742  |0 (DE-576)331358948  |4 aut 
700 1 |a Brockmann, Marc Alexander  |d 1974-  |e VerfasserIn  |0 (DE-588)128367334  |0 (DE-627)706967704  |0 (DE-576)297104489  |4 aut 
773 0 8 |i Enthalten in  |t Clinical neuroradiology  |d München : Urban & Vogel, 2006  |g 22(2012), 1, Seite 21-28  |h Online-Ressource  |w (DE-627)510935257  |w (DE-600)2232347-8  |w (DE-576)252954327  |x 1869-1447  |7 nnas  |a Comparison of digital subtraction angiography, micro-computed tomography angiography and magnetic resonance angiography in the assessment of the cerebrovascular system in live mice 
773 1 8 |g volume:22  |g year:2012  |g number:1  |g pages:21-28  |g extent:8  |a Comparison of digital subtraction angiography, micro-computed tomography angiography and magnetic resonance angiography in the assessment of the cerebrovascular system in live mice 
856 4 0 |u http://dx.doi.org/10.1007/s00062-011-0113-2  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://doi.org/10.1007/s00062-011-0113-2  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20181123 
993 |a Article 
994 |a 2012 
998 |g 128367334  |a Brockmann, Marc Alexander  |m 128367334:Brockmann, Marc Alexander  |d 60000  |d 63000  |e 60000PB128367334  |e 63000PB128367334  |k 0/60000/  |k 1/60000/63000/  |p 9  |y j 
998 |g 11292641X  |a Groden, Christoph  |m 11292641X:Groden, Christoph  |d 60000  |d 63000  |e 60000PG11292641X  |e 63000PG11292641X  |k 0/60000/  |k 1/60000/63000/  |p 8 
998 |g 1050701593  |a Fiebig, Anna Teresa  |m 1050701593:Fiebig, Anna Teresa  |d 60000  |d 63000  |e 60000PF1050701593  |e 63000PF1050701593  |k 0/60000/  |k 1/60000/63000/  |p 6 
998 |g 140930795  |a Schambach, Sebastian Jobst  |m 140930795:Schambach, Sebastian Jobst  |d 60000  |d 63000  |e 60000PS140930795  |e 63000PS140930795  |k 0/60000/  |k 1/60000/63000/  |p 5 
998 |g 1021211362  |a Heilmann, Melanie  |m 1021211362:Heilmann, Melanie  |d 60000  |d 63000  |e 60000PH1021211362  |e 63000PH1021211362  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 1025834739  |a Boll, Hanne  |m 1025834739:Boll, Hanne  |d 60000  |d 63000  |e 60000PB1025834739  |e 63000PB1025834739  |k 0/60000/  |k 1/60000/63000/  |p 3 
998 |g 1022165038  |a Brockmann, Carolin  |m 1022165038:Brockmann, Carolin  |d 60000  |d 63000  |e 60000PB1022165038  |e 63000PB1022165038  |k 0/60000/  |k 1/60000/63000/  |p 2 
998 |g 1038464072  |a Negrão de Figueiredo, Giovanna  |m 1038464072:Negrão de Figueiredo, Giovanna  |d 60000  |d 63000  |e 60000PN1038464072  |e 63000PN1038464072  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN1583989307  |e 3032945941 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Published online: 24 November 2011","Gesehen am 30.11.2018"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"recId":"1583989307","person":[{"display":"Negrão de Figueiredo Miller, Giovanna","roleDisplay":"VerfasserIn","role":"aut","family":"Negrão de Figueiredo Miller","given":"Giovanna"},{"role":"aut","display":"Brockmann, Carolin","roleDisplay":"VerfasserIn","given":"Carolin","family":"Brockmann"},{"family":"Boll","given":"Hanne","display":"Boll, Hanne","roleDisplay":"VerfasserIn","role":"aut"},{"display":"Heilmann, Melanie","roleDisplay":"VerfasserIn","role":"aut","family":"Heilmann","given":"Melanie"},{"roleDisplay":"VerfasserIn","display":"Schambach, Sebastian Jobst","role":"aut","family":"Schambach","given":"Sebastian Jobst"},{"family":"Fiebig","given":"Anna Teresa","display":"Fiebig, Anna Teresa","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Groden","given":"Christoph","roleDisplay":"VerfasserIn","display":"Groden, Christoph","role":"aut"},{"family":"Brockmann","given":"Marc Alexander","roleDisplay":"VerfasserIn","display":"Brockmann, Marc Alexander","role":"aut"}],"title":[{"title":"Comparison of digital subtraction angiography, micro-computed tomography angiography and magnetic resonance angiography in the assessment of the cerebrovascular system in live mice","title_sort":"Comparison of digital subtraction angiography, micro-computed tomography angiography and magnetic resonance angiography in the assessment of the cerebrovascular system in live mice"}],"physDesc":[{"extent":"8 S."}],"relHost":[{"id":{"issn":["1869-1447","1615-6706"],"zdb":["2232347-8"],"eki":["510935257"]},"origin":[{"dateIssuedKey":"2006","publisher":"Urban & Vogel","dateIssuedDisp":"2006-","publisherPlace":"München"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Clinical neuroradiology","title":"Clinical neuroradiology","subtitle":"official publication of the German, Austrian and Swiss societies of neuroradiology"}],"language":["eng"],"recId":"510935257","disp":"Comparison of digital subtraction angiography, micro-computed tomography angiography and magnetic resonance angiography in the assessment of the cerebrovascular system in live miceClinical neuroradiology","note":["Gesehen am 27.09.2018"],"type":{"media":"Online-Ressource","bibl":"periodical"},"part":{"text":"22(2012), 1, Seite 21-28","volume":"22","extent":"8","year":"2012","issue":"1","pages":"21-28"},"pubHistory":["16.2006 -"]}],"name":{"displayForm":["G. Figueiredo, C. Brockmann, H. Boll, M. Heilmann, S.J. Schambach, T. Fiebig, M. Kramer, C. Groden, M.A. Brockmann"]},"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"March 2012"}],"id":{"doi":["10.1007/s00062-011-0113-2"],"eki":["1583989307"]}} 
SRT |a NEGRAODEFICOMPARISON2012