A solution for the inner area of CBM-TOF with pad-MRPC
The Compressed Baryonic Matter (CBM) experiment has decided to use the Multi-gap Resistive Plate Chambers(MRPC) technology to build its Time-Of-Flight (TOF) wall. CBM-TOF requires a rate capability over 20kHz/cm2 for inner region. A 10-gap pad-MRPC assembled with low resistive glass is designed to c...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
11 February 2017
|
| In: |
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2017, Jahrgang: 845, Pages: 318-321 |
| ISSN: | 1872-9576 |
| DOI: | 10.1016/j.nima.2016.06.133 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1016/j.nima.2016.06.133 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0168900216307033 |
| Verfasserangaben: | Y. Wang, X.J. Huang, P F. Lyu, D. Han, B. Xie, Y.J. Li, N. Herrmann, I. Deppner, P. Loizeau, C. Simon, J. Frühauf, M. Kiš |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1584426462 | ||
| 003 | DE-627 | ||
| 005 | 20220815064456.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 181126s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.nima.2016.06.133 |2 doi | |
| 035 | |a (DE-627)1584426462 | ||
| 035 | |a (DE-576)514426462 | ||
| 035 | |a (DE-599)BSZ514426462 | ||
| 035 | |a (OCoLC)1341024244 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Wang, Yifei |e VerfasserIn |0 (DE-588)1047562111 |0 (DE-627)778558371 |0 (DE-576)401162338 |4 aut | |
| 245 | 1 | 2 | |a A solution for the inner area of CBM-TOF with pad-MRPC |c Y. Wang, X.J. Huang, P F. Lyu, D. Han, B. Xie, Y.J. Li, N. Herrmann, I. Deppner, P. Loizeau, C. Simon, J. Frühauf, M. Kiš |
| 264 | 1 | |c 11 February 2017 | |
| 300 | |a 4 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 30 June 2016 | ||
| 500 | |a Gesehen am 26.11.2018 | ||
| 520 | |a The Compressed Baryonic Matter (CBM) experiment has decided to use the Multi-gap Resistive Plate Chambers(MRPC) technology to build its Time-Of-Flight (TOF) wall. CBM-TOF requires a rate capability over 20kHz/cm2 for inner region. A 10-gap pad-MRPC assembled with low resistive glass is designed to construct this area. The prototypes, which consist of 10×0.22mm gas gaps and 2×8 20mm×20mm readout pads, require fewer electronic channels compared to the strip design. A timing resolution of around 60ps and an efficiency above 98% were obtained in a cosmic test and a beam test taken in 2014 October GSI beam time. The results show that the real-size prototypes fulfill the requirements of the CBM-TOF. | ||
| 650 | 4 | |a Beam test | |
| 650 | 4 | |a CBM-TOF | |
| 650 | 4 | |a High rate | |
| 650 | 4 | |a Pad-MRPC | |
| 650 | 4 | |a Timing resolution | |
| 700 | 1 | |a Herrmann, Norbert |e VerfasserIn |0 (DE-588)104952098X |0 (DE-627)782234399 |0 (DE-576)403514886 |4 aut | |
| 700 | 1 | |a Deppner, Ingo Martin |d 1974- |e VerfasserIn |0 (DE-588)1045034665 |0 (DE-627)773537198 |0 (DE-576)398347158 |4 aut | |
| 700 | 1 | |a Loizeau, Pierre-Alain |d 1985- |e VerfasserIn |0 (DE-588)1054162530 |0 (DE-627)791115208 |0 (DE-576)410044814 |4 aut | |
| 700 | 1 | |a Simon, Christian |d 1987- |e VerfasserIn |0 (DE-588)1139497197 |0 (DE-627)897225694 |0 (DE-576)493321152 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment |d [Amsterdam] : Elsevier, 1984 |g 845(2017), Seite 318-321 |h Online-Ressource |w (DE-627)266014666 |w (DE-600)1466532-3 |w (DE-576)074959743 |x 1872-9576 |7 nnas |a A solution for the inner area of CBM-TOF with pad-MRPC |
| 773 | 1 | 8 | |g volume:845 |g year:2017 |g pages:318-321 |g extent:4 |a A solution for the inner area of CBM-TOF with pad-MRPC |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.nima.2016.06.133 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0168900216307033 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20181126 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 1139497197 |a Simon, Christian |m 1139497197:Simon, Christian |d 130000 |d 130200 |e 130000PS1139497197 |e 130200PS1139497197 |k 0/130000/ |k 1/130000/130200/ |p 10 | ||
| 998 | |g 1054162530 |a Loizeau, Pierre-Alain |m 1054162530:Loizeau, Pierre-Alain |d 130000 |d 130200 |e 130000PL1054162530 |e 130200PL1054162530 |k 0/130000/ |k 1/130000/130200/ |p 9 | ||
| 998 | |g 1045034665 |a Deppner, Ingo Martin |m 1045034665:Deppner, Ingo Martin |d 130000 |d 130200 |e 130000PD1045034665 |e 130200PD1045034665 |k 0/130000/ |k 1/130000/130200/ |p 8 | ||
| 998 | |g 104952098X |a Herrmann, Norbert |m 104952098X:Herrmann, Norbert |d 130000 |d 130200 |e 130000PH104952098X |e 130200PH104952098X |k 0/130000/ |k 1/130000/130200/ |p 7 | ||
| 999 | |a KXP-PPN1584426462 |e 3034043554 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"title":[{"subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics","title_sort":"Nuclear instruments & methods in physics research","partname":"Accelerators, spectrometers, detectors and associated equipment","title":"Nuclear instruments & methods in physics research"}],"origin":[{"publisherPlace":"[Amsterdam] ; Amsterdam","dateIssuedKey":"1994","dateIssuedDisp":"1994-","publisher":"Elsevier ; North-Holland Publ. Co."}],"note":["Gesehen am 24.05.23"],"id":{"issn":["1872-9576"],"zdb":["1466532-3"],"eki":["266014666"]},"part":{"text":"845(2017), Seite 318-321","volume":"845","extent":"4","year":"2017","pages":"318-321"},"physDesc":[{"extent":"Online-Ressource"}],"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"language":["eng"],"disp":"A solution for the inner area of CBM-TOF with pad-MRPCNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","recId":"266014666","pubHistory":["Nachgewiesen 226.1984 -"],"type":{"media":"Online-Ressource","bibl":"periodical"}}],"note":["Available online 30 June 2016","Gesehen am 26.11.2018"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1584426462"],"doi":["10.1016/j.nima.2016.06.133"]},"physDesc":[{"extent":"4 S."}],"language":["eng"],"title":[{"title":"A solution for the inner area of CBM-TOF with pad-MRPC","title_sort":"solution for the inner area of CBM-TOF with pad-MRPC"}],"recId":"1584426462","origin":[{"dateIssuedDisp":"11 February 2017","dateIssuedKey":"2017"}],"name":{"displayForm":["Y. Wang, X.J. Huang, P F. Lyu, D. Han, B. Xie, Y.J. Li, N. Herrmann, I. Deppner, P. Loizeau, C. Simon, J. Frühauf, M. Kiš"]},"person":[{"role":"aut","given":"Yifei","display":"Wang, Yifei","family":"Wang"},{"given":"Norbert","display":"Herrmann, Norbert","family":"Herrmann","role":"aut"},{"role":"aut","family":"Deppner","given":"Ingo Martin","display":"Deppner, Ingo Martin"},{"role":"aut","family":"Loizeau","given":"Pierre-Alain","display":"Loizeau, Pierre-Alain"},{"role":"aut","family":"Simon","display":"Simon, Christian","given":"Christian"}]} | ||
| SRT | |a WANGYIFEIHSOLUTIONFO1120 | ||