A solution for the inner area of CBM-TOF with pad-MRPC

The Compressed Baryonic Matter (CBM) experiment has decided to use the Multi-gap Resistive Plate Chambers(MRPC) technology to build its Time-Of-Flight (TOF) wall. CBM-TOF requires a rate capability over 20kHz/cm2 for inner region. A 10-gap pad-MRPC assembled with low resistive glass is designed to c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wang, Yifei (VerfasserIn) , Herrmann, Norbert (VerfasserIn) , Deppner, Ingo Martin (VerfasserIn) , Loizeau, Pierre-Alain (VerfasserIn) , Simon, Christian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 11 February 2017
In: Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2017, Jahrgang: 845, Pages: 318-321
ISSN:1872-9576
DOI:10.1016/j.nima.2016.06.133
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.nima.2016.06.133
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0168900216307033
Volltext
Verfasserangaben:Y. Wang, X.J. Huang, P F. Lyu, D. Han, B. Xie, Y.J. Li, N. Herrmann, I. Deppner, P. Loizeau, C. Simon, J. Frühauf, M. Kiš

MARC

LEADER 00000caa a2200000 c 4500
001 1584426462
003 DE-627
005 20220815064456.0
007 cr uuu---uuuuu
008 181126s2017 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.nima.2016.06.133  |2 doi 
035 |a (DE-627)1584426462 
035 |a (DE-576)514426462 
035 |a (DE-599)BSZ514426462 
035 |a (OCoLC)1341024244 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Wang, Yifei  |e VerfasserIn  |0 (DE-588)1047562111  |0 (DE-627)778558371  |0 (DE-576)401162338  |4 aut 
245 1 2 |a A solution for the inner area of CBM-TOF with pad-MRPC  |c Y. Wang, X.J. Huang, P F. Lyu, D. Han, B. Xie, Y.J. Li, N. Herrmann, I. Deppner, P. Loizeau, C. Simon, J. Frühauf, M. Kiš 
264 1 |c 11 February 2017 
300 |a 4 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 30 June 2016 
500 |a Gesehen am 26.11.2018 
520 |a The Compressed Baryonic Matter (CBM) experiment has decided to use the Multi-gap Resistive Plate Chambers(MRPC) technology to build its Time-Of-Flight (TOF) wall. CBM-TOF requires a rate capability over 20kHz/cm2 for inner region. A 10-gap pad-MRPC assembled with low resistive glass is designed to construct this area. The prototypes, which consist of 10×0.22mm gas gaps and 2×8 20mm×20mm readout pads, require fewer electronic channels compared to the strip design. A timing resolution of around 60ps and an efficiency above 98% were obtained in a cosmic test and a beam test taken in 2014 October GSI beam time. The results show that the real-size prototypes fulfill the requirements of the CBM-TOF. 
650 4 |a Beam test 
650 4 |a CBM-TOF 
650 4 |a High rate 
650 4 |a Pad-MRPC 
650 4 |a Timing resolution 
700 1 |a Herrmann, Norbert  |e VerfasserIn  |0 (DE-588)104952098X  |0 (DE-627)782234399  |0 (DE-576)403514886  |4 aut 
700 1 |a Deppner, Ingo Martin  |d 1974-  |e VerfasserIn  |0 (DE-588)1045034665  |0 (DE-627)773537198  |0 (DE-576)398347158  |4 aut 
700 1 |a Loizeau, Pierre-Alain  |d 1985-  |e VerfasserIn  |0 (DE-588)1054162530  |0 (DE-627)791115208  |0 (DE-576)410044814  |4 aut 
700 1 |a Simon, Christian  |d 1987-  |e VerfasserIn  |0 (DE-588)1139497197  |0 (DE-627)897225694  |0 (DE-576)493321152  |4 aut 
773 0 8 |i Enthalten in  |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment  |d [Amsterdam] : Elsevier, 1984  |g 845(2017), Seite 318-321  |h Online-Ressource  |w (DE-627)266014666  |w (DE-600)1466532-3  |w (DE-576)074959743  |x 1872-9576  |7 nnas  |a A solution for the inner area of CBM-TOF with pad-MRPC 
773 1 8 |g volume:845  |g year:2017  |g pages:318-321  |g extent:4  |a A solution for the inner area of CBM-TOF with pad-MRPC 
856 4 0 |u http://dx.doi.org/10.1016/j.nima.2016.06.133  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0168900216307033  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20181126 
993 |a Article 
994 |a 2017 
998 |g 1139497197  |a Simon, Christian  |m 1139497197:Simon, Christian  |d 130000  |d 130200  |e 130000PS1139497197  |e 130200PS1139497197  |k 0/130000/  |k 1/130000/130200/  |p 10 
998 |g 1054162530  |a Loizeau, Pierre-Alain  |m 1054162530:Loizeau, Pierre-Alain  |d 130000  |d 130200  |e 130000PL1054162530  |e 130200PL1054162530  |k 0/130000/  |k 1/130000/130200/  |p 9 
998 |g 1045034665  |a Deppner, Ingo Martin  |m 1045034665:Deppner, Ingo Martin  |d 130000  |d 130200  |e 130000PD1045034665  |e 130200PD1045034665  |k 0/130000/  |k 1/130000/130200/  |p 8 
998 |g 104952098X  |a Herrmann, Norbert  |m 104952098X:Herrmann, Norbert  |d 130000  |d 130200  |e 130000PH104952098X  |e 130200PH104952098X  |k 0/130000/  |k 1/130000/130200/  |p 7 
999 |a KXP-PPN1584426462  |e 3034043554 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"title":[{"subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics","title_sort":"Nuclear instruments & methods in physics research","partname":"Accelerators, spectrometers, detectors and associated equipment","title":"Nuclear instruments & methods in physics research"}],"origin":[{"publisherPlace":"[Amsterdam] ; Amsterdam","dateIssuedKey":"1994","dateIssuedDisp":"1994-","publisher":"Elsevier ; North-Holland Publ. Co."}],"note":["Gesehen am 24.05.23"],"id":{"issn":["1872-9576"],"zdb":["1466532-3"],"eki":["266014666"]},"part":{"text":"845(2017), Seite 318-321","volume":"845","extent":"4","year":"2017","pages":"318-321"},"physDesc":[{"extent":"Online-Ressource"}],"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"language":["eng"],"disp":"A solution for the inner area of CBM-TOF with pad-MRPCNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","recId":"266014666","pubHistory":["Nachgewiesen 226.1984 -"],"type":{"media":"Online-Ressource","bibl":"periodical"}}],"note":["Available online 30 June 2016","Gesehen am 26.11.2018"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1584426462"],"doi":["10.1016/j.nima.2016.06.133"]},"physDesc":[{"extent":"4 S."}],"language":["eng"],"title":[{"title":"A solution for the inner area of CBM-TOF with pad-MRPC","title_sort":"solution for the inner area of CBM-TOF with pad-MRPC"}],"recId":"1584426462","origin":[{"dateIssuedDisp":"11 February 2017","dateIssuedKey":"2017"}],"name":{"displayForm":["Y. Wang, X.J. Huang, P F. Lyu, D. Han, B. Xie, Y.J. Li, N. Herrmann, I. Deppner, P. Loizeau, C. Simon, J. Frühauf, M. Kiš"]},"person":[{"role":"aut","given":"Yifei","display":"Wang, Yifei","family":"Wang"},{"given":"Norbert","display":"Herrmann, Norbert","family":"Herrmann","role":"aut"},{"role":"aut","family":"Deppner","given":"Ingo Martin","display":"Deppner, Ingo Martin"},{"role":"aut","family":"Loizeau","given":"Pierre-Alain","display":"Loizeau, Pierre-Alain"},{"role":"aut","family":"Simon","display":"Simon, Christian","given":"Christian"}]} 
SRT |a WANGYIFEIHSOLUTIONFO1120