A variational approach to image registration in dynamic contrast-enhanced MRI of the human kidney
Kidney function can be accessed by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measurements which yield spatially resolved maps of physiological parameters like perfusion or filtration. The motion of the kidneys during the scan is a dominant limitation of the measurement quality,...
Gespeichert in:
| Hauptverfasser: | , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
June 2013
|
| In: |
Magnetic resonance imaging
Year: 2013, Jahrgang: 31, Heft: 5, Pages: 771-777 |
| ISSN: | 1873-5894 |
| DOI: | 10.1016/j.mri.2012.10.011 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1016/j.mri.2012.10.011 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0730725X12004109 |
| Verfasserangaben: | Andreas D. Merrem, Frank G. Zöllner, Marcel Reich, Arvid Lundervold, Jarle Rorvik, Lothar R. Schad |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1585108189 | ||
| 003 | DE-627 | ||
| 005 | 20230427161344.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 181212s2013 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.mri.2012.10.011 |2 doi | |
| 035 | |a (DE-627)1585108189 | ||
| 035 | |a (DE-576)515108189 | ||
| 035 | |a (DE-599)BSZ515108189 | ||
| 035 | |a (OCoLC)1341026960 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Merrem, Andreas D. |e VerfasserIn |0 (DE-588)1170740251 |0 (DE-627)1039961460 |0 (DE-576)512633010 |4 aut | |
| 245 | 1 | 2 | |a A variational approach to image registration in dynamic contrast-enhanced MRI of the human kidney |c Andreas D. Merrem, Frank G. Zöllner, Marcel Reich, Arvid Lundervold, Jarle Rorvik, Lothar R. Schad |
| 264 | 1 | |c June 2013 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Online 7 December 2012 | ||
| 500 | |a Gesehen am 12.12.2018 | ||
| 520 | |a Kidney function can be accessed by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measurements which yield spatially resolved maps of physiological parameters like perfusion or filtration. The motion of the kidneys during the scan is a dominant limitation of the measurement quality, and image registration is necessary for accurate quantification. We analyzed the feasibility of applying an algorithm, originally developed for multimodal registration, to kidney perfusion time series. The algorithm uses a variational calculation scheme to align the images. In four out of five data sets, kidney motion could be reduced to below the spatial resolution of the images of 1.6mm while preserving the enhancement pattern of kidney perfusion. Fitting a pharmacokinetic model to the data showed an average reduction of the Akaike fit error of 10% for the registered data, suggesting more stable parameters. We conclude that this image registration algorithm is feasible for correcting kidney motion in renal DCE-MRI. | ||
| 650 | 4 | |a DCE-MRI | |
| 650 | 4 | |a Image registration | |
| 650 | 4 | |a Kidney | |
| 650 | 4 | |a Perfusion analysis | |
| 700 | 1 | |a Zöllner, Frank G. |d 1976- |e VerfasserIn |0 (DE-588)129580015 |0 (DE-627)473357054 |0 (DE-576)297732587 |4 aut | |
| 700 | 1 | |a Schad, Lothar R. |d 1956- |e VerfasserIn |0 (DE-588)1028817630 |0 (DE-627)731640241 |0 (DE-576)376271221 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Magnetic resonance imaging |d Amsterdam [u.a.] : Elsevier Science, 1982 |g 31(2013), 5, Seite 771-777 |h Online-Ressource |w (DE-627)306661160 |w (DE-600)1500646-3 |w (DE-576)081986750 |x 1873-5894 |7 nnas |a A variational approach to image registration in dynamic contrast-enhanced MRI of the human kidney |
| 773 | 1 | 8 | |g volume:31 |g year:2013 |g number:5 |g pages:771-777 |g extent:7 |a A variational approach to image registration in dynamic contrast-enhanced MRI of the human kidney |
| 776 | 0 | 8 | |i Erscheint auch als |n Druck-Ausgabe |t A variational approach to image registration in dynamic contrast-enhanced MRI of the human kidney |d 2013 |w (DE-627)1461827949 |w (DE-576)391827944 |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.mri.2012.10.011 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0730725X12004109 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20181212 | ||
| 993 | |a Article | ||
| 994 | |a 2013 | ||
| 998 | |g 1028817630 |a Schad, Lothar R. |m 1028817630:Schad, Lothar R. |p 6 |y j | ||
| 998 | |g 129580015 |a Zöllner, Frank G. |m 129580015:Zöllner, Frank G. |p 2 | ||
| 998 | |g 1170740251 |a Merrem, Andreas D. |m 1170740251:Merrem, Andreas D. |p 1 |x j | ||
| 999 | |a KXP-PPN1585108189 |e 3037760966 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"physDesc":[{"extent":"7 S."}],"name":{"displayForm":["Andreas D. Merrem, Frank G. Zöllner, Marcel Reich, Arvid Lundervold, Jarle Rorvik, Lothar R. Schad"]},"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"recId":"306661160","id":{"zdb":["1500646-3"],"issn":["1873-5894"],"eki":["306661160"]},"pubHistory":["1.1982 -"],"note":["Gesehen am 29.01.2020"],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1982-","dateIssuedKey":"1982","publisher":"Elsevier Science"}],"title":[{"subtitle":"an international journal of basic research and clinical applications","title_sort":"Magnetic resonance imaging","title":"Magnetic resonance imaging"}],"disp":"A variational approach to image registration in dynamic contrast-enhanced MRI of the human kidneyMagnetic resonance imaging","type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"part":{"volume":"31","extent":"7","text":"31(2013), 5, Seite 771-777","issue":"5","year":"2013","pages":"771-777"}}],"recId":"1585108189","id":{"eki":["1585108189"],"doi":["10.1016/j.mri.2012.10.011"]},"title":[{"title_sort":"variational approach to image registration in dynamic contrast-enhanced MRI of the human kidney","title":"A variational approach to image registration in dynamic contrast-enhanced MRI of the human kidney"}],"note":["Online 7 December 2012","Gesehen am 12.12.2018"],"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"June 2013"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"person":[{"display":"Merrem, Andreas D.","family":"Merrem","given":"Andreas D.","role":"aut"},{"family":"Zöllner","display":"Zöllner, Frank G.","role":"aut","given":"Frank G."},{"role":"aut","given":"Lothar R.","display":"Schad, Lothar R.","family":"Schad"}]} | ||
| SRT | |a MERREMANDRVARIATIONA2013 | ||