Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients: initial experience with 3rd generation dual-source CT

Purpose: Minimizing radiation dose while at the same time preserving image quality is of particular importance in pediatric chest CT. Very recently, CT imaging with a tube voltage of 70 kVp has become clinically available. However, image noise is inversely proportional to the tube voltage. We aimed...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Henzler, Claudia (VerfasserIn) , Henzler, Thomas (VerfasserIn) , Haubenreisser, Holger (VerfasserIn) , Meyer, Mathias (VerfasserIn) , Janssen, Sonja (VerfasserIn) , Schönberg, Stefan (VerfasserIn) , Neff, Wolfgang (VerfasserIn) , Weis, Meike (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2016
In: Zeitschrift für medizinische Physik
Year: 2015, Jahrgang: 26, Heft: 4, Pages: 349-361
ISSN:1876-4436
DOI:10.1016/j.zemedi.2015.11.002
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.zemedi.2015.11.002
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0939388915001488
Volltext
Verfasserangaben:Claudia Hagelstein, Thomas Henzler, Holger Haubenreisser, Mathias Meyer, Sonja Sudarski, Stefan O. Schoenberg, K. Wolfgang Neff, Meike Weis

MARC

LEADER 00000caa a2200000 c 4500
001 1586317326
003 DE-627
005 20230427034206.0
007 cr uuu---uuuuu
008 190117r20162015xx |||||o 00| ||eng c
024 7 |a 10.1016/j.zemedi.2015.11.002  |2 doi 
035 |a (DE-627)1586317326 
035 |a (DE-576)516317326 
035 |a (DE-599)BSZ516317326 
035 |a (OCoLC)1341033683 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Henzler, Claudia  |d 1985-  |e VerfasserIn  |0 (DE-588)1031664017  |0 (DE-627)737088850  |0 (DE-576)379358409  |4 aut 
245 1 0 |a Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients  |b initial experience with 3rd generation dual-source CT  |c Claudia Hagelstein, Thomas Henzler, Holger Haubenreisser, Mathias Meyer, Sonja Sudarski, Stefan O. Schoenberg, K. Wolfgang Neff, Meike Weis 
246 3 3 |a Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients$dinitial experience with 3 rd generation dual-source CT 
264 1 |c 2016 
300 |a 13 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 15 December 2015 
500 |a rd im Zusatztitel ist hochgestellt 
500 |a Gesehen am 17.01.2019 
520 |a Purpose: Minimizing radiation dose while at the same time preserving image quality is of particular importance in pediatric chest CT. Very recently, CT imaging with a tube voltage of 70 kVp has become clinically available. However, image noise is inversely proportional to the tube voltage. We aimed to investigate radiation dose and image quality of pediatric chest CT performed at 70 kVp in an anthropomorphic pediatric phantom as well as in clinical patients. Methods and Materials: An anthropomorphic pediatric phantom, which resembles a one-year-old child in physiognomy, was scanned on the 3rd generation dual-source CT (DSCT) system at 70 kVp and 80 kVp and a fixed ultra low tube-current of 8 mAs to solely evaluate the impact of lowering tube voltage. After the phantom measurements, 18 pediatric patients (mean 29.5 months; range 1-91 months; 21 examinations) underwent 3.2 high-pitch chest CT on the same DSCT system at 70 kVp tube voltage without any sedation. Radiation dose and presence of motion artifacts was compared to a retrospectively identified patient cohort examined at 80 kVp on a 16-slice single-source-CT (SSCT; n=15; 14/15 with sedation; mean 30.7 months; range 0-96 months; pitch=1.5) or on a 2nd generation DSCT without any sedation (n=6; mean 32.8 months; range 4-61 months; pitch=3.2). Results: Radiation dose in the phantom scans was reduced by approximately 40% when using a tube voltage of 70 kVp instead of 80 kVp. In the pediatric patient group examined at 70 kVp age-specific effective dose (ED; mean 0.5±0.2 mSv) was significantly lower when compared to the retrospective cohort scanned at 80 kVp on the 16-slice-SSCT (mean ED: 1.0±0.3 mSv; p<0.0001) and also considerably lower when compared to the cohort scanned at 80 kVp on the 2nd generation DSCT (mean ED: 0.9±0.5 mSv). None of the prospective, sedation-free CT examinations showed any motion artifacts whereas 13/15 examinations of the retrospective patient cohort scanned at 80 kVp with a pitch of 1.5 showed motion artifacts. Conclusion: 3.2 high-pitch chest CT performed with 70 kVp significantly reduces radiation dose when compared to 80 kVp while at the same time provides good image quality without any motion artifacts even without sedation. 
534 |c 2015 
650 4 |a Bildqualität 
650 4 |a chest computed tomography 
650 4 |a high-pitch imaging 
650 4 |a High-pitch-Bildgebung 
650 4 |a image quality 
650 4 |a pädiatrische CT 
650 4 |a pediatric CT 
650 4 |a Radiation dose reduction 
650 4 |a sedation-free CT 
650 4 |a sedierungsfreie CT 
650 4 |a Strahlendosisreduktion 
650 4 |a thorakale Computertomographie 
700 1 |a Henzler, Thomas  |d 1980-  |e VerfasserIn  |0 (DE-588)134001486  |0 (DE-627)559468415  |0 (DE-576)276829948  |4 aut 
700 1 |a Haubenreisser, Holger  |d 1985-  |e VerfasserIn  |0 (DE-588)1050055322  |0 (DE-627)783257791  |0 (DE-576)404356281  |4 aut 
700 1 |a Meyer, Mathias  |d 1986-  |e VerfasserIn  |0 (DE-588)1025310306  |0 (DE-627)722026021  |0 (DE-576)370193059  |4 aut 
700 1 |a Janssen, Sonja  |d 1987-  |e VerfasserIn  |0 (DE-588)1033103748  |0 (DE-627)74078871X  |0 (DE-576)380756110  |4 aut 
700 1 |a Schönberg, Stefan  |d 1969-  |e VerfasserIn  |0 (DE-588)131557912  |0 (DE-627)510700624  |0 (DE-576)298584891  |4 aut 
700 1 |a Neff, Wolfgang  |e VerfasserIn  |0 (DE-588)1026440521  |0 (DE-627)726733539  |0 (DE-576)371782465  |4 aut 
700 1 |a Weis, Meike  |d 1986-  |e VerfasserIn  |0 (DE-588)1058122274  |0 (DE-627)796423881  |0 (DE-576)414125274  |4 aut 
773 0 8 |i Enthalten in  |t Zeitschrift für medizinische Physik  |d Amsterdam [u.a.] : Elsevier, 1990  |g 26(2016), 4, Seite 349-361  |w (DE-627)510617662  |w (DE-600)2231492-1  |w (DE-576)272350818  |x 1876-4436  |7 nnas  |a Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients initial experience with 3rd generation dual-source CT 
773 1 8 |g volume:26  |g year:2016  |g number:4  |g pages:349-361  |g extent:13  |a Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients initial experience with 3rd generation dual-source CT 
856 4 0 |u http://dx.doi.org/10.1016/j.zemedi.2015.11.002  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0939388915001488  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190117 
993 |a Article 
994 |a 2016 
998 |g 1058122274  |a Weis, Meike  |m 1058122274:Weis, Meike  |d 60000  |d 62900  |e 60000PW1058122274  |e 62900PW1058122274  |k 0/60000/  |k 1/60000/62900/  |p 8  |y j 
998 |g 1026440521  |a Neff, Wolfgang  |m 1026440521:Neff, Wolfgang  |d 60000  |d 62900  |e 60000PN1026440521  |e 62900PN1026440521  |k 0/60000/  |k 1/60000/62900/  |p 7 
998 |g 131557912  |a Schönberg, Stefan  |m 131557912:Schönberg, Stefan  |d 60000  |d 62900  |e 60000PS131557912  |e 62900PS131557912  |k 0/60000/  |k 1/60000/62900/  |p 6 
998 |g 1033103748  |a Janssen, Sonja  |m 1033103748:Janssen, Sonja  |d 60000  |d 62900  |e 60000PJ1033103748  |e 62900PJ1033103748  |k 0/60000/  |k 1/60000/62900/  |p 5 
998 |g 1025310306  |a Meyer, Mathias  |m 1025310306:Meyer, Mathias  |d 60000  |d 62900  |e 60000PM1025310306  |e 62900PM1025310306  |k 0/60000/  |k 1/60000/62900/  |p 4 
998 |g 1050055322  |a Haubenreisser, Holger  |m 1050055322:Haubenreisser, Holger  |d 60000  |d 62900  |e 60000PH1050055322  |e 62900PH1050055322  |k 0/60000/  |k 1/60000/62900/  |p 3 
998 |g 134001486  |a Henzler, Thomas  |m 134001486:Henzler, Thomas  |d 60000  |e 60000PH134001486  |k 0/60000/  |p 2 
998 |g 1031664017  |a Henzler, Claudia  |m 1031664017:Henzler, Claudia  |d 60000  |d 62900  |e 60000PH1031664017  |e 62900PH1031664017  |k 0/60000/  |k 1/60000/62900/  |p 1  |x j 
999 |a KXP-PPN1586317326  |e 3045945503 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"13 S."}],"id":{"eki":["1586317326"],"doi":["10.1016/j.zemedi.2015.11.002"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Available online 15 December 2015","rd im Zusatztitel ist hochgestellt","Gesehen am 17.01.2019"],"relHost":[{"titleAlt":[{"title":"Medizinische Physik"}],"language":["ger"],"disp":"Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients initial experience with 3rd generation dual-source CTZeitschrift für medizinische Physik","recId":"510617662","type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["Volume 1, supplement (1990) ; volume 1, issue 1 (1991)-"],"title":[{"subtitle":"offizielles Organ der Deutschen, Österreichischen und Schweizerischen Gesellschaft für Medizinische Physik","title_sort":"Zeitschrift für medizinische Physik","title":"Zeitschrift für medizinische Physik"}],"corporate":[{"role":"isb","display":"Deutsche Gesellschaft für Medizinische Physik"},{"role":"isb","display":"Österreichische Gesellschaft für Medizinische Physik"}],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1990","dateIssuedDisp":"1990-","publisher":"Elsevier"}],"note":["Gesehen am 31.01.2022"],"part":{"issue":"4","extent":"13","text":"26(2016), 4, Seite 349-361","volume":"26","pages":"349-361","year":"2016"},"id":{"zdb":["2231492-1"],"issn":["1876-4436"],"eki":["510617662"]}}],"person":[{"given":"Claudia","display":"Henzler, Claudia","family":"Henzler","role":"aut"},{"role":"aut","display":"Henzler, Thomas","given":"Thomas","family":"Henzler"},{"family":"Haubenreisser","given":"Holger","display":"Haubenreisser, Holger","role":"aut"},{"family":"Meyer","display":"Meyer, Mathias","given":"Mathias","role":"aut"},{"family":"Janssen","display":"Janssen, Sonja","given":"Sonja","role":"aut"},{"role":"aut","family":"Schönberg","given":"Stefan","display":"Schönberg, Stefan"},{"role":"aut","family":"Neff","given":"Wolfgang","display":"Neff, Wolfgang"},{"role":"aut","family":"Weis","display":"Weis, Meike","given":"Meike"}],"origin":[{"dateIssuedDisp":"2016","dateIssuedKey":"2016"}],"name":{"displayForm":["Claudia Hagelstein, Thomas Henzler, Holger Haubenreisser, Mathias Meyer, Sonja Sudarski, Stefan O. Schoenberg, K. Wolfgang Neff, Meike Weis"]},"recId":"1586317326","title":[{"title":"Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients","title_sort":"Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients","subtitle":"initial experience with 3rd generation dual-source CT"}],"language":["eng"],"titleAlt":[{"title":"Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients$dinitial experience with 3 rd generation dual-source CT"}]} 
SRT |a HENZLERCLAULTRAHIGHP2016