Comparison between atrial fibrillation-triggered implantable cardioverter-defibrillator (ICD) shocks and inappropriate shocks caused by lead failure: different impact on prognosis in clinical practice

Prognostic Impact of Inappropriate Shocks. Introduction: Recent studies suggest a worse impact of inappropriate shock therapies on the outcome of patients with an implantable cardioverter-defibrillator (ICD). However, it is not known whether the worse impact is attributed to the ICD shock itself or...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kleemann, Thomas (VerfasserIn) , Hochadel, Matthias (VerfasserIn) , Strauß, Margit (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 07 February 2012
In: Journal of cardiovascular electrophysiology
Year: 2012, Jahrgang: 23, Heft: 7, Pages: 735-740
ISSN:1540-8167
DOI:10.1111/j.1540-8167.2011.02279.x
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1111/j.1540-8167.2011.02279.x
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1540-8167.2011.02279.x
Volltext
Verfasserangaben:Thomas Kleemann, Matthias Hochadel, Margit Strauss, Alexandros Skarlos, Karlheinz Seidl, Ralf Zahn

MARC

LEADER 00000caa a2200000 c 4500
001 158730502X
003 DE-627
005 20230427034230.0
007 cr uuu---uuuuu
008 190206s2012 xx |||||o 00| ||eng c
024 7 |a 10.1111/j.1540-8167.2011.02279.x  |2 doi 
035 |a (DE-627)158730502X 
035 |a (DE-576)51730502X 
035 |a (DE-599)BSZ51730502X 
035 |a (OCoLC)1341036041 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Kleemann, Thomas  |d 1970-  |e VerfasserIn  |0 (DE-588)123322375  |0 (DE-627)706255038  |0 (DE-576)161728162  |4 aut 
245 1 0 |a Comparison between atrial fibrillation-triggered implantable cardioverter-defibrillator (ICD) shocks and inappropriate shocks caused by lead failure  |b different impact on prognosis in clinical practice  |c Thomas Kleemann, Matthias Hochadel, Margit Strauss, Alexandros Skarlos, Karlheinz Seidl, Ralf Zahn 
264 1 |c 07 February 2012 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 06.02.2019 
520 |a Prognostic Impact of Inappropriate Shocks. Introduction: Recent studies suggest a worse impact of inappropriate shock therapies on the outcome of patients with an implantable cardioverter-defibrillator (ICD). However, it is not known whether the worse impact is attributed to the ICD shock itself or due to the underlying heart disease. The aim of the study was to evaluate the impact of inappropriate ICD shocks on clinical outcome by comparing ICD shocks triggered by atrial fibrillation (AF) with shocks caused by lead failure. Methods and Results: A total of 1,411 consecutive patients of the prospective single-center ICD-registry Ludwigshafen who underwent an ICD implantation between 1992 and 2008 for primary or secondary prevention of sudden cardiac death were analyzed. During the median follow-up of 3 years, 297 (21%) patients experienced inappropriate ICD shocks. Sixty percent of patients had inappropriate shocks due to AF and 24% due to lead defect or T-wave oversensing. Multiple ICD shocks (≥2) triggered by AF were associated with a worse prognosis, whereas a single shock due to AF or 1 or multiple shocks resulting from lead failure were not. ICD shocks caused by AF occurred more often in tandem with a serious adverse event than in patients with a lead failure (15% vs 6%, P < 0.05). Conclusion: Multiple ICD shocks triggered by AF are associated with a worse prognosis in ICD patients, whereas a single shock due to AF or shocks resulting from lead failure are not. These data support that the ICD shock itself has no worse impact on the outcome of ICD patients. (J Cardiovasc Electrophysiol, Vol. 23, pp. 735-740, July 2012) 
650 4 |a atrial fibrillation 
650 4 |a implantable cardioverter-defibrillator 
650 4 |a inappropriate shock 
650 4 |a lead failure 
650 4 |a sudden death 
700 1 |a Hochadel, Matthias  |e VerfasserIn  |0 (DE-588)1128413051  |0 (DE-627)88289871X  |0 (DE-576)485901811  |4 aut 
700 1 |a Strauß, Margit  |e VerfasserIn  |0 (DE-588)1177151642  |0 (DE-627)1048588459  |0 (DE-576)517304996  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cardiovascular electrophysiology  |d Oxford : Wiley-Blackwell, 1990  |g 23(2012), 7, Seite 735-740  |h Online-Ressource  |w (DE-627)325572011  |w (DE-600)2037519-0  |w (DE-576)094114013  |x 1540-8167  |7 nnas  |a Comparison between atrial fibrillation-triggered implantable cardioverter-defibrillator (ICD) shocks and inappropriate shocks caused by lead failure different impact on prognosis in clinical practice 
773 1 8 |g volume:23  |g year:2012  |g number:7  |g pages:735-740  |g extent:6  |a Comparison between atrial fibrillation-triggered implantable cardioverter-defibrillator (ICD) shocks and inappropriate shocks caused by lead failure different impact on prognosis in clinical practice 
856 4 0 |u http://dx.doi.org/10.1111/j.1540-8167.2011.02279.x  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1540-8167.2011.02279.x  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20190206 
993 |a Article 
994 |a 2012 
998 |g 1128413051  |a Hochadel, Matthias  |m 1128413051:Hochadel, Matthias  |p 2 
999 |a KXP-PPN158730502X  |e 3055096983 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"07 February 2012"}],"id":{"eki":["158730502X"],"doi":["10.1111/j.1540-8167.2011.02279.x"]},"recId":"158730502X","relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Journal of cardiovascular electrophysiology","subtitle":"JCE ; an official journal of the North American Society of Pacing and Electrophysiology ; the official journal of the Cardiac Electrophysiology Society","title_sort":"Journal of cardiovascular electrophysiology"}],"language":["eng"],"note":["Gesehen am 24.03.11"],"origin":[{"dateIssuedKey":"1990","publisherPlace":"Oxford ; Armonk, NY ; Oxford [u.a.]","dateIssuedDisp":"1990-","publisher":"Wiley-Blackwell ; Futura Publ. Co. ; Blackwell Publishing"}],"id":{"eki":["325572011"],"zdb":["2037519-0"],"issn":["1540-8167"],"doi":["10.1111/(ISSN)1540-8167"]},"pubHistory":["1.1990 -"],"disp":"Comparison between atrial fibrillation-triggered implantable cardioverter-defibrillator (ICD) shocks and inappropriate shocks caused by lead failure different impact on prognosis in clinical practiceJournal of cardiovascular electrophysiology","part":{"year":"2012","extent":"6","issue":"7","text":"23(2012), 7, Seite 735-740","pages":"735-740","volume":"23"},"recId":"325572011","titleAlt":[{"title":"JCE"}],"type":{"bibl":"periodical","media":"Online-Ressource"}}],"person":[{"given":"Thomas","role":"aut","family":"Kleemann","display":"Kleemann, Thomas"},{"given":"Matthias","display":"Hochadel, Matthias","family":"Hochadel","role":"aut"},{"given":"Margit","family":"Strauß","display":"Strauß, Margit","role":"aut"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 06.02.2019"],"name":{"displayForm":["Thomas Kleemann, Matthias Hochadel, Margit Strauss, Alexandros Skarlos, Karlheinz Seidl, Ralf Zahn"]},"title":[{"title_sort":"Comparison between atrial fibrillation-triggered implantable cardioverter-defibrillator (ICD) shocks and inappropriate shocks caused by lead failure","subtitle":"different impact on prognosis in clinical practice","title":"Comparison between atrial fibrillation-triggered implantable cardioverter-defibrillator (ICD) shocks and inappropriate shocks caused by lead failure"}],"language":["eng"],"physDesc":[{"extent":"6 S."}]} 
SRT |a KLEEMANNTHCOMPARISON0720