Central corneal thickness in spectral-domain OCT and associations with ocular and systemic parameters
Background. Optical coherence tomography (OCT) allows quantitative analysis of the anterior segment of the eye with a noncontact examination. The aim of this study is to analyze associations of central corneal thickness (CCT) as measured by OCT with ocular and systemic cardiovascular parameters. Met...
Gespeichert in:
| Hauptverfasser: | , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2016
|
| In: |
Journal of ophthalmology
Year: 2016, Pages: 1-6 |
| ISSN: | 2090-0058 |
| DOI: | 10.1155/2016/2596956 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1155/2016/2596956 Verlag, Volltext: https://www.hindawi.com/journals/joph/2016/2596956/ |
| Verfasserangaben: | Alexander Karl-Georg Schuster, Joachim Ernst Fischer, and Urs Vossmerbaeumer |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1587801701 | ||
| 003 | DE-627 | ||
| 005 | 20241209145152.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 190219s2016 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1155/2016/2596956 |2 doi | |
| 035 | |a (DE-627)1587801701 | ||
| 035 | |a (DE-576)517801701 | ||
| 035 | |a (DE-599)BSZ517801701 | ||
| 035 | |a (OCoLC)1341038808 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Schuster, Alexander K. |d 1985- |e VerfasserIn |0 (DE-588)1049518810 |0 (DE-627)782185789 |0 (DE-576)403510139 |4 aut | |
| 245 | 1 | 0 | |a Central corneal thickness in spectral-domain OCT and associations with ocular and systemic parameters |c Alexander Karl-Georg Schuster, Joachim Ernst Fischer, and Urs Vossmerbaeumer |
| 264 | 1 | |c 2016 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 19.02.2019 | ||
| 520 | |a Background. Optical coherence tomography (OCT) allows quantitative analysis of the anterior segment of the eye with a noncontact examination. The aim of this study is to analyze associations of central corneal thickness (CCT) as measured by OCT with ocular and systemic cardiovascular parameters. Methods. A cross-sectional study of 734 persons was performed in a working age population. Only healthy eyes were included. A comprehensive ophthalmological examination including refraction, noncontact tonometry, and imaging of the anterior segment by SD-OCT was performed. In parallel, a broad range of systemic cardiovascular parameters were measured. Associations were analyzed using a generalized estimating equations’ model. Results. CCT measurements showed a significant association with corneal curvature and intraocular pressure: a thinner CCT was associated with a flatter cornea and with lower intraocular pressure (). Age was positively associated with CCT (); all other cardiovascular parameters were not associated. Conclusion. A thinner cornea is associated with a flatter surface and with lower intraocular pressure readings, while there are no independent associations with refraction and systemic cardiovascular parameters. Our findings highlight the value of SD-OCT CCT measurements as a standard tool in anterior segment analysis. | ||
| 700 | 1 | |a Fischer, Joachim E. |d 1957- |e VerfasserIn |0 (DE-588)1029135800 |0 (DE-627)732480620 |0 (DE-576)37658775X |4 aut | |
| 700 | 1 | |a Voßmerbäumer, Urs |d 1973- |e VerfasserIn |0 (DE-588)121535819 |0 (DE-627)705518868 |0 (DE-576)292759541 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of ophthalmology |d [Hoboken, NJ] : Wiley, 2009 |g (2016), Artikel-ID 2596956, Seite 1-6 |h Online-Ressource |w (DE-627)62318270X |w (DE-600)2546525-9 |w (DE-576)321467523 |x 2090-0058 |7 nnas |a Central corneal thickness in spectral-domain OCT and associations with ocular and systemic parameters |
| 773 | 1 | 8 | |g year:2016 |g elocationid:2596956 |g pages:1-6 |g extent:6 |a Central corneal thickness in spectral-domain OCT and associations with ocular and systemic parameters |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1155/2016/2596956 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://www.hindawi.com/journals/joph/2016/2596956/ |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20190219 | ||
| 993 | |a Article | ||
| 994 | |a 2016 | ||
| 998 | |g 121535819 |a Voßmerbäumer, Urs |m 121535819:Voßmerbäumer, Urs |d 60000 |d 65300 |e 60000PV121535819 |e 65300PV121535819 |k 0/60000/ |k 1/60000/65300/ |p 3 |y j | ||
| 998 | |g 1029135800 |a Fischer, Joachim E. |m 1029135800:Fischer, Joachim E. |d 60000 |d 65300 |e 60000PF1029135800 |e 65300PF1029135800 |k 0/60000/ |k 1/60000/65300/ |p 2 | ||
| 999 | |a KXP-PPN1587801701 |e 3056203422 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"language":["eng"],"part":{"extent":"6","text":"(2016), Artikel-ID 2596956, Seite 1-6","year":"2016","pages":"1-6"},"recId":"62318270X","physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["62318270X"],"issn":["2090-0058"],"zdb":["2546525-9"]},"title":[{"title_sort":"Journal of ophthalmology","title":"Journal of ophthalmology"}],"pubHistory":["2009 -"],"note":["Gesehen am 08.09.2021"],"origin":[{"publisher":"Wiley ; Hindawi","dateIssuedKey":"2024","dateIssuedDisp":"2024-","publisherPlace":"[Hoboken, NJ] ; New York, NY"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Central corneal thickness in spectral-domain OCT and associations with ocular and systemic parametersJournal of ophthalmology"}],"recId":"1587801701","name":{"displayForm":["Alexander Karl-Georg Schuster, Joachim Ernst Fischer, and Urs Vossmerbaeumer"]},"physDesc":[{"extent":"6 S."}],"id":{"eki":["1587801701"],"doi":["10.1155/2016/2596956"]},"note":["Gesehen am 19.02.2019"],"origin":[{"dateIssuedDisp":"2016","dateIssuedKey":"2016"}],"title":[{"title":"Central corneal thickness in spectral-domain OCT and associations with ocular and systemic parameters","title_sort":"Central corneal thickness in spectral-domain OCT and associations with ocular and systemic parameters"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"person":[{"given":"Alexander K.","role":"aut","family":"Schuster","display":"Schuster, Alexander K."},{"family":"Fischer","display":"Fischer, Joachim E.","given":"Joachim E.","role":"aut"},{"display":"Voßmerbäumer, Urs","family":"Voßmerbäumer","given":"Urs","role":"aut"}]} | ||
| SRT | |a SCHUSTERALCENTRALCOR2016 | ||